Numerical analysis of reinforced concrete beam subject to pitting corrosion

Detalhes bibliográficos
Autor(a) principal: Ramos,Éverton Souza
Data de Publicação: 2022
Outros Autores: Carrazedo,Rogério
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Ambiente construído (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-86212022000100201
Resumo: Abstract This paper presents a numerical study about the effects of chloride-induced corrosion on the service life of structures. A two-dimensional geometrically nonlinear mechanical model based on Finite Element Method (FEM) was developed for reinforced concrete structures. The corrosion initiation stage was evaluated by Fick's diffusion laws. The corrosion propagation was carried out by deterministic models based on Faraday's law. Pitting corrosion was simulated in the reinforcements by pit elements, distributed longitudinally on the steel rebars, which degrade the physical properties over time. The service life was determined by the crack width.Two parametric analyses were performed. In the first analysis, five models were created with a variablecover thickness and water/cement ratio (w/c). In the second analysis, the reduction in yield stress due to corrosion was considered.The results showed that the concrete cover thicknessand the w/c ratio significantly influence the service life. The reduction of the cover thickness from 30 mm to 25 mm resulted in 21.26% reduction in service life, whilethe increase in the w/c ratio from 0.50 to 0.55 caused 32.98% reduction in service life of the structural element analyzed.
id ANTAC-1_9c6df1c714a8ee289727e1ade102578f
oai_identifier_str oai:scielo:S1678-86212022000100201
network_acronym_str ANTAC-1
network_name_str Ambiente construído (Online)
repository_id_str
spelling Numerical analysis of reinforced concrete beam subject to pitting corrosionReinforced concrete structuresChloride-induced corrosionPitting corrosionService lifeAbstract This paper presents a numerical study about the effects of chloride-induced corrosion on the service life of structures. A two-dimensional geometrically nonlinear mechanical model based on Finite Element Method (FEM) was developed for reinforced concrete structures. The corrosion initiation stage was evaluated by Fick's diffusion laws. The corrosion propagation was carried out by deterministic models based on Faraday's law. Pitting corrosion was simulated in the reinforcements by pit elements, distributed longitudinally on the steel rebars, which degrade the physical properties over time. The service life was determined by the crack width.Two parametric analyses were performed. In the first analysis, five models were created with a variablecover thickness and water/cement ratio (w/c). In the second analysis, the reduction in yield stress due to corrosion was considered.The results showed that the concrete cover thicknessand the w/c ratio significantly influence the service life. The reduction of the cover thickness from 30 mm to 25 mm resulted in 21.26% reduction in service life, whilethe increase in the w/c ratio from 0.50 to 0.55 caused 32.98% reduction in service life of the structural element analyzed.Associação Nacional de Tecnologia do Ambiente Construído - ANTAC2022-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-86212022000100201Ambiente Construído v.22 n.1 2022reponame:Ambiente construído (Online)instname:Associação Nacional de Tecnologia do Ambiente Construído (ANTAC)instacron:ANTAC10.1590/s1678-86212022000100588info:eu-repo/semantics/openAccessRamos,Éverton SouzaCarrazedo,Rogérioeng2021-10-28T00:00:00Zoai:scielo:S1678-86212022000100201Revistahttps://seer.ufrgs.br/ambienteconstruidohttps://old.scielo.br/oai/scielo-oai.php||ambienteconstruido@ufrgs.br1678-86211415-8876opendoar:2021-10-28T00:00Ambiente construído (Online) - Associação Nacional de Tecnologia do Ambiente Construído (ANTAC)false
dc.title.none.fl_str_mv Numerical analysis of reinforced concrete beam subject to pitting corrosion
title Numerical analysis of reinforced concrete beam subject to pitting corrosion
spellingShingle Numerical analysis of reinforced concrete beam subject to pitting corrosion
Ramos,Éverton Souza
Reinforced concrete structures
Chloride-induced corrosion
Pitting corrosion
Service life
title_short Numerical analysis of reinforced concrete beam subject to pitting corrosion
title_full Numerical analysis of reinforced concrete beam subject to pitting corrosion
title_fullStr Numerical analysis of reinforced concrete beam subject to pitting corrosion
title_full_unstemmed Numerical analysis of reinforced concrete beam subject to pitting corrosion
title_sort Numerical analysis of reinforced concrete beam subject to pitting corrosion
author Ramos,Éverton Souza
author_facet Ramos,Éverton Souza
Carrazedo,Rogério
author_role author
author2 Carrazedo,Rogério
author2_role author
dc.contributor.author.fl_str_mv Ramos,Éverton Souza
Carrazedo,Rogério
dc.subject.por.fl_str_mv Reinforced concrete structures
Chloride-induced corrosion
Pitting corrosion
Service life
topic Reinforced concrete structures
Chloride-induced corrosion
Pitting corrosion
Service life
description Abstract This paper presents a numerical study about the effects of chloride-induced corrosion on the service life of structures. A two-dimensional geometrically nonlinear mechanical model based on Finite Element Method (FEM) was developed for reinforced concrete structures. The corrosion initiation stage was evaluated by Fick's diffusion laws. The corrosion propagation was carried out by deterministic models based on Faraday's law. Pitting corrosion was simulated in the reinforcements by pit elements, distributed longitudinally on the steel rebars, which degrade the physical properties over time. The service life was determined by the crack width.Two parametric analyses were performed. In the first analysis, five models were created with a variablecover thickness and water/cement ratio (w/c). In the second analysis, the reduction in yield stress due to corrosion was considered.The results showed that the concrete cover thicknessand the w/c ratio significantly influence the service life. The reduction of the cover thickness from 30 mm to 25 mm resulted in 21.26% reduction in service life, whilethe increase in the w/c ratio from 0.50 to 0.55 caused 32.98% reduction in service life of the structural element analyzed.
publishDate 2022
dc.date.none.fl_str_mv 2022-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-86212022000100201
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-86212022000100201
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1678-86212022000100588
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Associação Nacional de Tecnologia do Ambiente Construído - ANTAC
publisher.none.fl_str_mv Associação Nacional de Tecnologia do Ambiente Construído - ANTAC
dc.source.none.fl_str_mv Ambiente Construído v.22 n.1 2022
reponame:Ambiente construído (Online)
instname:Associação Nacional de Tecnologia do Ambiente Construído (ANTAC)
instacron:ANTAC
instname_str Associação Nacional de Tecnologia do Ambiente Construído (ANTAC)
instacron_str ANTAC
institution ANTAC
reponame_str Ambiente construído (Online)
collection Ambiente construído (Online)
repository.name.fl_str_mv Ambiente construído (Online) - Associação Nacional de Tecnologia do Ambiente Construído (ANTAC)
repository.mail.fl_str_mv ||ambienteconstruido@ufrgs.br
_version_ 1754209105286791168