Floor impact noise performance of prefabricated prestressed joists and block slabs with wooden laminate floors
Autor(a) principal: | |
---|---|
Data de Publicação: | 2022 |
Outros Autores: | , , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Ambiente construído (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-86212022000400335 |
Resumo: | Abstract This research aims to discuss and determine acoustic performance values for impact noise insulation (L’nT,w) for 39 floor system compositions that have different resilient materials and wooden laminate floor finishing. The methodology is organized according to ISO 16283-2, ISO 717-2 and NBR 15575-3 for classification. The results obtained demonstrate that the prefabricated ribbed slab with prestressed joists and ceramic slabs, as well as the slab and subfloor system do not meet the minimum requirements for acoustic insulation, comprising values of 91 and 84 dB, respectively. Among the other 37 samples, it is worth mentioning that wooden laminate floors with better abrasion resistance is more efficient concerning acoustic performance, comprising impact noise insulation values ranging from 60 to 62 dB, due to its surface density. In the samples that use resilient materials, the performance values vary from 55 to 46 dB. |
id |
ANTAC-1_fbe60ac194482a60352b74879b0845db |
---|---|
oai_identifier_str |
oai:scielo:S1678-86212022000400335 |
network_acronym_str |
ANTAC-1 |
network_name_str |
Ambiente construído (Online) |
repository_id_str |
|
spelling |
Floor impact noise performance of prefabricated prestressed joists and block slabs with wooden laminate floorsArchitectural acousticsSound insulationBuilding performanceAbstract This research aims to discuss and determine acoustic performance values for impact noise insulation (L’nT,w) for 39 floor system compositions that have different resilient materials and wooden laminate floor finishing. The methodology is organized according to ISO 16283-2, ISO 717-2 and NBR 15575-3 for classification. The results obtained demonstrate that the prefabricated ribbed slab with prestressed joists and ceramic slabs, as well as the slab and subfloor system do not meet the minimum requirements for acoustic insulation, comprising values of 91 and 84 dB, respectively. Among the other 37 samples, it is worth mentioning that wooden laminate floors with better abrasion resistance is more efficient concerning acoustic performance, comprising impact noise insulation values ranging from 60 to 62 dB, due to its surface density. In the samples that use resilient materials, the performance values vary from 55 to 46 dB.Associação Nacional de Tecnologia do Ambiente Construído - ANTAC2022-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-86212022000400335Ambiente Construído v.22 n.4 2022reponame:Ambiente construído (Online)instname:Associação Nacional de Tecnologia do Ambiente Construído (ANTAC)instacron:ANTAC10.1590/s1678-86212022000400643info:eu-repo/semantics/openAccessLourenço,Willian Magalhães deMeller,GabrielaRossi,Camila TacianeHaas,AlessandraSantos,Eduardo Henrique LuccaSantos,Joaquim Cesar Pizzutti dosMelo,Viviane Suzey Gomes deTenenbaum,Roberto AizikMohamad,Gihadeng2022-09-05T00:00:00Zoai:scielo:S1678-86212022000400335Revistahttps://seer.ufrgs.br/ambienteconstruidohttps://old.scielo.br/oai/scielo-oai.php||ambienteconstruido@ufrgs.br1678-86211415-8876opendoar:2022-09-05T00:00Ambiente construído (Online) - Associação Nacional de Tecnologia do Ambiente Construído (ANTAC)false |
dc.title.none.fl_str_mv |
Floor impact noise performance of prefabricated prestressed joists and block slabs with wooden laminate floors |
title |
Floor impact noise performance of prefabricated prestressed joists and block slabs with wooden laminate floors |
spellingShingle |
Floor impact noise performance of prefabricated prestressed joists and block slabs with wooden laminate floors Lourenço,Willian Magalhães de Architectural acoustics Sound insulation Building performance |
title_short |
Floor impact noise performance of prefabricated prestressed joists and block slabs with wooden laminate floors |
title_full |
Floor impact noise performance of prefabricated prestressed joists and block slabs with wooden laminate floors |
title_fullStr |
Floor impact noise performance of prefabricated prestressed joists and block slabs with wooden laminate floors |
title_full_unstemmed |
Floor impact noise performance of prefabricated prestressed joists and block slabs with wooden laminate floors |
title_sort |
Floor impact noise performance of prefabricated prestressed joists and block slabs with wooden laminate floors |
author |
Lourenço,Willian Magalhães de |
author_facet |
Lourenço,Willian Magalhães de Meller,Gabriela Rossi,Camila Taciane Haas,Alessandra Santos,Eduardo Henrique Lucca Santos,Joaquim Cesar Pizzutti dos Melo,Viviane Suzey Gomes de Tenenbaum,Roberto Aizik Mohamad,Gihad |
author_role |
author |
author2 |
Meller,Gabriela Rossi,Camila Taciane Haas,Alessandra Santos,Eduardo Henrique Lucca Santos,Joaquim Cesar Pizzutti dos Melo,Viviane Suzey Gomes de Tenenbaum,Roberto Aizik Mohamad,Gihad |
author2_role |
author author author author author author author author |
dc.contributor.author.fl_str_mv |
Lourenço,Willian Magalhães de Meller,Gabriela Rossi,Camila Taciane Haas,Alessandra Santos,Eduardo Henrique Lucca Santos,Joaquim Cesar Pizzutti dos Melo,Viviane Suzey Gomes de Tenenbaum,Roberto Aizik Mohamad,Gihad |
dc.subject.por.fl_str_mv |
Architectural acoustics Sound insulation Building performance |
topic |
Architectural acoustics Sound insulation Building performance |
description |
Abstract This research aims to discuss and determine acoustic performance values for impact noise insulation (L’nT,w) for 39 floor system compositions that have different resilient materials and wooden laminate floor finishing. The methodology is organized according to ISO 16283-2, ISO 717-2 and NBR 15575-3 for classification. The results obtained demonstrate that the prefabricated ribbed slab with prestressed joists and ceramic slabs, as well as the slab and subfloor system do not meet the minimum requirements for acoustic insulation, comprising values of 91 and 84 dB, respectively. Among the other 37 samples, it is worth mentioning that wooden laminate floors with better abrasion resistance is more efficient concerning acoustic performance, comprising impact noise insulation values ranging from 60 to 62 dB, due to its surface density. In the samples that use resilient materials, the performance values vary from 55 to 46 dB. |
publishDate |
2022 |
dc.date.none.fl_str_mv |
2022-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-86212022000400335 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-86212022000400335 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/s1678-86212022000400643 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Nacional de Tecnologia do Ambiente Construído - ANTAC |
publisher.none.fl_str_mv |
Associação Nacional de Tecnologia do Ambiente Construído - ANTAC |
dc.source.none.fl_str_mv |
Ambiente Construído v.22 n.4 2022 reponame:Ambiente construído (Online) instname:Associação Nacional de Tecnologia do Ambiente Construído (ANTAC) instacron:ANTAC |
instname_str |
Associação Nacional de Tecnologia do Ambiente Construído (ANTAC) |
instacron_str |
ANTAC |
institution |
ANTAC |
reponame_str |
Ambiente construído (Online) |
collection |
Ambiente construído (Online) |
repository.name.fl_str_mv |
Ambiente construído (Online) - Associação Nacional de Tecnologia do Ambiente Construído (ANTAC) |
repository.mail.fl_str_mv |
||ambienteconstruido@ufrgs.br |
_version_ |
1754209105366482944 |