Intra and interobserver reliability of the interpretation of high-resolution computed tomography on the lungs of premature infants
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | São Paulo medical journal (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-31802010000300005 |
Resumo: | CONTEXT AND OBJECTIVE: High-resolution computed tomography (HRCT) of the lungs is more sensitive than radiographs for evaluating pulmonary disease, but little has been described about HRCT interpretation during the neonatal period or shortly afterwards. The aim here was to evaluate the reliability of the interpretation of HRCT among very low birth weight premature infants (VLBWPI; < 1500 g). DESIGN AND SETTING: Cross-sectional study on intra and interobserver reliability of HRCT on VLBWPI. METHODS: 86 VLBWPI underwent HRCT. Two pediatric radiologists analyzed the HRCT images. The reliability was measured by the proportion of agreement, kappa coefficient (KC) and positive and negative agreement indices. RESULTS: For radiologist A, the intraobserver reliability KC was 0.79 (confidence interval, CI: 0.54-1.00) for normal/abnormal examinations; for each abnormality on CT, KC ranged from 0.05 to 1.00. For radiologist B, the intraobserver reliability KC was 0.79 (CI: 0.54-1.00) for normal/abnormal examinations; for each abnormality on CT, KC ranged from 0.37 to 0.83. The interobserver agreement was 88% for normal/abnormal examinations and KC was 0.71 (CI: 0.5- 0.93); for most abnormal findings, KC ranged from 0.51-0.67. CONCLUSION: For normal/abnormal examinations, the intra and interobserver agreements were substantial. For most of the imaging findings, the intraobserver agreement ranged from moderate to substantial. Our data demonstrate that in clinical practice, there is no reason for more than one tomographic image evaluator, provided that this person is well trained in VLBWPI HRCT interpretation. Analysis by different observers should be reserved for research and for difficult cases in clinical contexts. |
id |
APM-1_51821b5e3033a5fbc3b7eadc6bc311b3 |
---|---|
oai_identifier_str |
oai:scielo:S1516-31802010000300005 |
network_acronym_str |
APM-1 |
network_name_str |
São Paulo medical journal (Online) |
repository_id_str |
|
spelling |
Intra and interobserver reliability of the interpretation of high-resolution computed tomography on the lungs of premature infantsTomography, X-ray computedInfant, prematureLungBronchopulmonary dysplasiaReproducibility of resultsInfantCONTEXT AND OBJECTIVE: High-resolution computed tomography (HRCT) of the lungs is more sensitive than radiographs for evaluating pulmonary disease, but little has been described about HRCT interpretation during the neonatal period or shortly afterwards. The aim here was to evaluate the reliability of the interpretation of HRCT among very low birth weight premature infants (VLBWPI; < 1500 g). DESIGN AND SETTING: Cross-sectional study on intra and interobserver reliability of HRCT on VLBWPI. METHODS: 86 VLBWPI underwent HRCT. Two pediatric radiologists analyzed the HRCT images. The reliability was measured by the proportion of agreement, kappa coefficient (KC) and positive and negative agreement indices. RESULTS: For radiologist A, the intraobserver reliability KC was 0.79 (confidence interval, CI: 0.54-1.00) for normal/abnormal examinations; for each abnormality on CT, KC ranged from 0.05 to 1.00. For radiologist B, the intraobserver reliability KC was 0.79 (CI: 0.54-1.00) for normal/abnormal examinations; for each abnormality on CT, KC ranged from 0.37 to 0.83. The interobserver agreement was 88% for normal/abnormal examinations and KC was 0.71 (CI: 0.5- 0.93); for most abnormal findings, KC ranged from 0.51-0.67. CONCLUSION: For normal/abnormal examinations, the intra and interobserver agreements were substantial. For most of the imaging findings, the intraobserver agreement ranged from moderate to substantial. Our data demonstrate that in clinical practice, there is no reason for more than one tomographic image evaluator, provided that this person is well trained in VLBWPI HRCT interpretation. Analysis by different observers should be reserved for research and for difficult cases in clinical contexts.Associação Paulista de Medicina - APM2010-05-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-31802010000300005Sao Paulo Medical Journal v.128 n.3 2010reponame:São Paulo medical journal (Online)instname:Associação Paulista de Medicinainstacron:APM10.1590/S1516-31802010000300005info:eu-repo/semantics/openAccessBoëchat,Márcia Cristina BastosMello,Rosane Reis deDutra,Maria Virgínia PeixotoSilva,Kátia Silveira daDaltro,PedroMarchiori,Edsoneng2010-10-13T00:00:00Zoai:scielo:S1516-31802010000300005Revistahttp://www.scielo.br/spmjhttps://old.scielo.br/oai/scielo-oai.phprevistas@apm.org.br1806-94601516-3180opendoar:2010-10-13T00:00São Paulo medical journal (Online) - Associação Paulista de Medicinafalse |
dc.title.none.fl_str_mv |
Intra and interobserver reliability of the interpretation of high-resolution computed tomography on the lungs of premature infants |
title |
Intra and interobserver reliability of the interpretation of high-resolution computed tomography on the lungs of premature infants |
spellingShingle |
Intra and interobserver reliability of the interpretation of high-resolution computed tomography on the lungs of premature infants Boëchat,Márcia Cristina Bastos Tomography, X-ray computed Infant, premature Lung Bronchopulmonary dysplasia Reproducibility of results Infant |
title_short |
Intra and interobserver reliability of the interpretation of high-resolution computed tomography on the lungs of premature infants |
title_full |
Intra and interobserver reliability of the interpretation of high-resolution computed tomography on the lungs of premature infants |
title_fullStr |
Intra and interobserver reliability of the interpretation of high-resolution computed tomography on the lungs of premature infants |
title_full_unstemmed |
Intra and interobserver reliability of the interpretation of high-resolution computed tomography on the lungs of premature infants |
title_sort |
Intra and interobserver reliability of the interpretation of high-resolution computed tomography on the lungs of premature infants |
author |
Boëchat,Márcia Cristina Bastos |
author_facet |
Boëchat,Márcia Cristina Bastos Mello,Rosane Reis de Dutra,Maria Virgínia Peixoto Silva,Kátia Silveira da Daltro,Pedro Marchiori,Edson |
author_role |
author |
author2 |
Mello,Rosane Reis de Dutra,Maria Virgínia Peixoto Silva,Kátia Silveira da Daltro,Pedro Marchiori,Edson |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Boëchat,Márcia Cristina Bastos Mello,Rosane Reis de Dutra,Maria Virgínia Peixoto Silva,Kátia Silveira da Daltro,Pedro Marchiori,Edson |
dc.subject.por.fl_str_mv |
Tomography, X-ray computed Infant, premature Lung Bronchopulmonary dysplasia Reproducibility of results Infant |
topic |
Tomography, X-ray computed Infant, premature Lung Bronchopulmonary dysplasia Reproducibility of results Infant |
description |
CONTEXT AND OBJECTIVE: High-resolution computed tomography (HRCT) of the lungs is more sensitive than radiographs for evaluating pulmonary disease, but little has been described about HRCT interpretation during the neonatal period or shortly afterwards. The aim here was to evaluate the reliability of the interpretation of HRCT among very low birth weight premature infants (VLBWPI; < 1500 g). DESIGN AND SETTING: Cross-sectional study on intra and interobserver reliability of HRCT on VLBWPI. METHODS: 86 VLBWPI underwent HRCT. Two pediatric radiologists analyzed the HRCT images. The reliability was measured by the proportion of agreement, kappa coefficient (KC) and positive and negative agreement indices. RESULTS: For radiologist A, the intraobserver reliability KC was 0.79 (confidence interval, CI: 0.54-1.00) for normal/abnormal examinations; for each abnormality on CT, KC ranged from 0.05 to 1.00. For radiologist B, the intraobserver reliability KC was 0.79 (CI: 0.54-1.00) for normal/abnormal examinations; for each abnormality on CT, KC ranged from 0.37 to 0.83. The interobserver agreement was 88% for normal/abnormal examinations and KC was 0.71 (CI: 0.5- 0.93); for most abnormal findings, KC ranged from 0.51-0.67. CONCLUSION: For normal/abnormal examinations, the intra and interobserver agreements were substantial. For most of the imaging findings, the intraobserver agreement ranged from moderate to substantial. Our data demonstrate that in clinical practice, there is no reason for more than one tomographic image evaluator, provided that this person is well trained in VLBWPI HRCT interpretation. Analysis by different observers should be reserved for research and for difficult cases in clinical contexts. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-05-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-31802010000300005 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-31802010000300005 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1516-31802010000300005 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Paulista de Medicina - APM |
publisher.none.fl_str_mv |
Associação Paulista de Medicina - APM |
dc.source.none.fl_str_mv |
Sao Paulo Medical Journal v.128 n.3 2010 reponame:São Paulo medical journal (Online) instname:Associação Paulista de Medicina instacron:APM |
instname_str |
Associação Paulista de Medicina |
instacron_str |
APM |
institution |
APM |
reponame_str |
São Paulo medical journal (Online) |
collection |
São Paulo medical journal (Online) |
repository.name.fl_str_mv |
São Paulo medical journal (Online) - Associação Paulista de Medicina |
repository.mail.fl_str_mv |
revistas@apm.org.br |
_version_ |
1754209262621425664 |