Effect of light curing units on color stability and mechanical properties of resin cements after aging

Detalhes bibliográficos
Autor(a) principal: Farina, Morgana Fernandes de Freitas
Data de Publicação: 2024
Outros Autores: Moda, Mariana Dias, Fagundes, Ticiane Cestari, Briso, André Luiz Fraga, dos Santos, Paulo Henrique
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Health Review
Texto Completo: https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/67591
Resumo: This study aimed to evaluate the color stability, Martens hardness (HMV), and modulus of elasticity (Eit*) of resin cements light-cured using two types of light-emitting diodes (LED) subjected to ultraviolet (UV) aging. Two resin cements were used: light-cured (RelyX Veener) and dual-cured (Variolink II). Forty discs were confectioned for each resin cement (with a diameter of 5 mm and thickness of 1.5 mm). Half of the samples were light-cured by a Radii-cal singlewave and the other half by a Valo® polywave. The specimens were then stored at 37 °C and 100% relative humidity for 24 h to ensure complete polymerization. Baseline evaluations of the color alteration, HMV, and Eit* were performed. The specimens were aged for 252 h in an UV-accelerated aging chamber. Then, a final analysis was performed. Two-way repeated-measures ANOVA was performed on the color changes. Meanwhile, three-way repeated-measures ANOVA followed by Tukey´s test was performed on HMV and Eit* to compare the means (α = 0.05). With regard to the color alteration (ΔE), there was no statistically significant difference between the materials or between the light curing units (p > 0.05). With regard to the mechanical properties, Valo® promoted high values of HMV and Eit* compared with Radii-cal (p < 0.05). With regard to the resin cements, Variolink II showed higher HMV and Eit* values than RelyX Veneer (p < 0.05), except for Eit* after UV aging. The light-curing unit influenced the mechanical properties but not the color stability of the resin cements.
id BJRH-0_64345aa86e285fc337d7d6667ac4160b
oai_identifier_str oai:ojs2.ojs.brazilianjournals.com.br:article/67591
network_acronym_str BJRH-0
network_name_str Brazilian Journal of Health Review
repository_id_str
spelling Effect of light curing units on color stability and mechanical properties of resin cements after agingcolor stabilitydental cementshardness testlight curing unitphotoinitiatorsThis study aimed to evaluate the color stability, Martens hardness (HMV), and modulus of elasticity (Eit*) of resin cements light-cured using two types of light-emitting diodes (LED) subjected to ultraviolet (UV) aging. Two resin cements were used: light-cured (RelyX Veener) and dual-cured (Variolink II). Forty discs were confectioned for each resin cement (with a diameter of 5 mm and thickness of 1.5 mm). Half of the samples were light-cured by a Radii-cal singlewave and the other half by a Valo® polywave. The specimens were then stored at 37 °C and 100% relative humidity for 24 h to ensure complete polymerization. Baseline evaluations of the color alteration, HMV, and Eit* were performed. The specimens were aged for 252 h in an UV-accelerated aging chamber. Then, a final analysis was performed. Two-way repeated-measures ANOVA was performed on the color changes. Meanwhile, three-way repeated-measures ANOVA followed by Tukey´s test was performed on HMV and Eit* to compare the means (α = 0.05). With regard to the color alteration (ΔE), there was no statistically significant difference between the materials or between the light curing units (p > 0.05). With regard to the mechanical properties, Valo® promoted high values of HMV and Eit* compared with Radii-cal (p < 0.05). With regard to the resin cements, Variolink II showed higher HMV and Eit* values than RelyX Veneer (p < 0.05), except for Eit* after UV aging. The light-curing unit influenced the mechanical properties but not the color stability of the resin cements.Brazilian Journals Publicações de Periódicos e Editora Ltda.2024-02-27info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/6759110.34119/bjhrv7n1-579Brazilian Journal of Health Review; Vol. 7 No. 1 (2024); 7101-7114Brazilian Journal of Health Review; Vol. 7 Núm. 1 (2024); 7101-7114Brazilian Journal of Health Review; v. 7 n. 1 (2024); 7101-71142595-6825reponame:Brazilian Journal of Health Reviewinstname:Federação das Indústrias do Estado do Paraná (FIEP)instacron:BJRHenghttps://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/67591/48100Farina, Morgana Fernandes de FreitasModa, Mariana DiasFagundes, Ticiane CestariBriso, André Luiz Fragados Santos, Paulo Henriqueinfo:eu-repo/semantics/openAccess2024-02-27T14:30:15Zoai:ojs2.ojs.brazilianjournals.com.br:article/67591Revistahttp://www.brazilianjournals.com/index.php/BJHR/indexPRIhttps://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/oai|| brazilianjhr@gmail.com2595-68252595-6825opendoar:2024-02-27T14:30:15Brazilian Journal of Health Review - Federação das Indústrias do Estado do Paraná (FIEP)false
dc.title.none.fl_str_mv Effect of light curing units on color stability and mechanical properties of resin cements after aging
title Effect of light curing units on color stability and mechanical properties of resin cements after aging
spellingShingle Effect of light curing units on color stability and mechanical properties of resin cements after aging
Farina, Morgana Fernandes de Freitas
color stability
dental cements
hardness test
light curing unit
photoinitiators
title_short Effect of light curing units on color stability and mechanical properties of resin cements after aging
title_full Effect of light curing units on color stability and mechanical properties of resin cements after aging
title_fullStr Effect of light curing units on color stability and mechanical properties of resin cements after aging
title_full_unstemmed Effect of light curing units on color stability and mechanical properties of resin cements after aging
title_sort Effect of light curing units on color stability and mechanical properties of resin cements after aging
author Farina, Morgana Fernandes de Freitas
author_facet Farina, Morgana Fernandes de Freitas
Moda, Mariana Dias
Fagundes, Ticiane Cestari
Briso, André Luiz Fraga
dos Santos, Paulo Henrique
author_role author
author2 Moda, Mariana Dias
Fagundes, Ticiane Cestari
Briso, André Luiz Fraga
dos Santos, Paulo Henrique
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Farina, Morgana Fernandes de Freitas
Moda, Mariana Dias
Fagundes, Ticiane Cestari
Briso, André Luiz Fraga
dos Santos, Paulo Henrique
dc.subject.por.fl_str_mv color stability
dental cements
hardness test
light curing unit
photoinitiators
topic color stability
dental cements
hardness test
light curing unit
photoinitiators
description This study aimed to evaluate the color stability, Martens hardness (HMV), and modulus of elasticity (Eit*) of resin cements light-cured using two types of light-emitting diodes (LED) subjected to ultraviolet (UV) aging. Two resin cements were used: light-cured (RelyX Veener) and dual-cured (Variolink II). Forty discs were confectioned for each resin cement (with a diameter of 5 mm and thickness of 1.5 mm). Half of the samples were light-cured by a Radii-cal singlewave and the other half by a Valo® polywave. The specimens were then stored at 37 °C and 100% relative humidity for 24 h to ensure complete polymerization. Baseline evaluations of the color alteration, HMV, and Eit* were performed. The specimens were aged for 252 h in an UV-accelerated aging chamber. Then, a final analysis was performed. Two-way repeated-measures ANOVA was performed on the color changes. Meanwhile, three-way repeated-measures ANOVA followed by Tukey´s test was performed on HMV and Eit* to compare the means (α = 0.05). With regard to the color alteration (ΔE), there was no statistically significant difference between the materials or between the light curing units (p > 0.05). With regard to the mechanical properties, Valo® promoted high values of HMV and Eit* compared with Radii-cal (p < 0.05). With regard to the resin cements, Variolink II showed higher HMV and Eit* values than RelyX Veneer (p < 0.05), except for Eit* after UV aging. The light-curing unit influenced the mechanical properties but not the color stability of the resin cements.
publishDate 2024
dc.date.none.fl_str_mv 2024-02-27
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/67591
10.34119/bjhrv7n1-579
url https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/67591
identifier_str_mv 10.34119/bjhrv7n1-579
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/67591/48100
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Brazilian Journals Publicações de Periódicos e Editora Ltda.
publisher.none.fl_str_mv Brazilian Journals Publicações de Periódicos e Editora Ltda.
dc.source.none.fl_str_mv Brazilian Journal of Health Review; Vol. 7 No. 1 (2024); 7101-7114
Brazilian Journal of Health Review; Vol. 7 Núm. 1 (2024); 7101-7114
Brazilian Journal of Health Review; v. 7 n. 1 (2024); 7101-7114
2595-6825
reponame:Brazilian Journal of Health Review
instname:Federação das Indústrias do Estado do Paraná (FIEP)
instacron:BJRH
instname_str Federação das Indústrias do Estado do Paraná (FIEP)
instacron_str BJRH
institution BJRH
reponame_str Brazilian Journal of Health Review
collection Brazilian Journal of Health Review
repository.name.fl_str_mv Brazilian Journal of Health Review - Federação das Indústrias do Estado do Paraná (FIEP)
repository.mail.fl_str_mv || brazilianjhr@gmail.com
_version_ 1797240043104894976