Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report
Autor(a) principal: | |
---|---|
Data de Publicação: | 2023 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Health Review |
Texto Completo: | https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/57476 |
Resumo: | The introduction of computer-aided design and computer-aided manufacturing in rehabilitation with removable partial denture, enabled the emergence of new methods of fabrication of the framework and materials. In view of this, polyether-ether-ketone appears as an alternative to Cobalt-Chromium, due to its aesthetic properties, high resistance and for being non-allergic. In this sense, the present study aimed to report a clinical case where the framework of a removable partial denture was manufactured from a digital workflow, using polyether-ether-ketone as the material of choice, compared to a removable partial denture made with a cobalt-chromium framework. In this case, it was possible to perceive that the use of computer-aided design and computer-aided manufacturing technology for the construction of a removable partial denture framework of polyether-ether-ketone resulted in a denture with adequate adaptation and good aesthetics. Patient satisfaction, comfort, retention, number of follow-up sessions, masticatory performance and quality of life were evaluated. Compared with the conventional denture, the polyether-ether-ketone framework denture provided better satisfaction and comfort. Both prostheses showed similar results in terms of masticatory performance and in terms of quality of life, however the polyether-ether-ketone framework denture showed better results. In conclusion, polyether-ether-ketone proved to be a viable material for making removable partial denture framework. However, controlled and randomized clinical trials are needed to demonstrate the benefits of this treatment as an alternative in relation to the conventional denture. |
id |
BJRH-0_d9ade06f8e43ea9e91be091842e68116 |
---|---|
oai_identifier_str |
oai:ojs2.ojs.brazilianjournals.com.br:article/57476 |
network_acronym_str |
BJRH-0 |
network_name_str |
Brazilian Journal of Health Review |
repository_id_str |
|
spelling |
Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case reportremovable partial denturebiomedical and dental materialspolymerstechnologycomputer-aided designThe introduction of computer-aided design and computer-aided manufacturing in rehabilitation with removable partial denture, enabled the emergence of new methods of fabrication of the framework and materials. In view of this, polyether-ether-ketone appears as an alternative to Cobalt-Chromium, due to its aesthetic properties, high resistance and for being non-allergic. In this sense, the present study aimed to report a clinical case where the framework of a removable partial denture was manufactured from a digital workflow, using polyether-ether-ketone as the material of choice, compared to a removable partial denture made with a cobalt-chromium framework. In this case, it was possible to perceive that the use of computer-aided design and computer-aided manufacturing technology for the construction of a removable partial denture framework of polyether-ether-ketone resulted in a denture with adequate adaptation and good aesthetics. Patient satisfaction, comfort, retention, number of follow-up sessions, masticatory performance and quality of life were evaluated. Compared with the conventional denture, the polyether-ether-ketone framework denture provided better satisfaction and comfort. Both prostheses showed similar results in terms of masticatory performance and in terms of quality of life, however the polyether-ether-ketone framework denture showed better results. In conclusion, polyether-ether-ketone proved to be a viable material for making removable partial denture framework. However, controlled and randomized clinical trials are needed to demonstrate the benefits of this treatment as an alternative in relation to the conventional denture.Brazilian Journals Publicações de Periódicos e Editora Ltda.2023-02-22info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/5747610.34119/bjhrv6n1-312Brazilian Journal of Health Review; Vol. 6 No. 1 (2023); 4027-4039Brazilian Journal of Health Review; Vol. 6 Núm. 1 (2023); 4027-4039Brazilian Journal of Health Review; v. 6 n. 1 (2023); 4027-40392595-6825reponame:Brazilian Journal of Health Reviewinstname:Federação das Indústrias do Estado do Paraná (FIEP)instacron:BJRHenghttps://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/57476/42019Curinga, Míria Rafaelli Souzada Silva, Gabriel GomesPereira, Ana Larisse Carneirode Freitas, Rodrigo Falcão Carvalho PortoCarreiro, Adriana da Fonte Portoinfo:eu-repo/semantics/openAccess2023-02-24T20:07:15Zoai:ojs2.ojs.brazilianjournals.com.br:article/57476Revistahttp://www.brazilianjournals.com/index.php/BJHR/indexPRIhttps://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/oai|| brazilianjhr@gmail.com2595-68252595-6825opendoar:2023-02-24T20:07:15Brazilian Journal of Health Review - Federação das Indústrias do Estado do Paraná (FIEP)false |
dc.title.none.fl_str_mv |
Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report |
title |
Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report |
spellingShingle |
Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report Curinga, Míria Rafaelli Souza removable partial denture biomedical and dental materials polymers technology computer-aided design |
title_short |
Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report |
title_full |
Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report |
title_fullStr |
Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report |
title_full_unstemmed |
Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report |
title_sort |
Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report |
author |
Curinga, Míria Rafaelli Souza |
author_facet |
Curinga, Míria Rafaelli Souza da Silva, Gabriel Gomes Pereira, Ana Larisse Carneiro de Freitas, Rodrigo Falcão Carvalho Porto Carreiro, Adriana da Fonte Porto |
author_role |
author |
author2 |
da Silva, Gabriel Gomes Pereira, Ana Larisse Carneiro de Freitas, Rodrigo Falcão Carvalho Porto Carreiro, Adriana da Fonte Porto |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Curinga, Míria Rafaelli Souza da Silva, Gabriel Gomes Pereira, Ana Larisse Carneiro de Freitas, Rodrigo Falcão Carvalho Porto Carreiro, Adriana da Fonte Porto |
dc.subject.por.fl_str_mv |
removable partial denture biomedical and dental materials polymers technology computer-aided design |
topic |
removable partial denture biomedical and dental materials polymers technology computer-aided design |
description |
The introduction of computer-aided design and computer-aided manufacturing in rehabilitation with removable partial denture, enabled the emergence of new methods of fabrication of the framework and materials. In view of this, polyether-ether-ketone appears as an alternative to Cobalt-Chromium, due to its aesthetic properties, high resistance and for being non-allergic. In this sense, the present study aimed to report a clinical case where the framework of a removable partial denture was manufactured from a digital workflow, using polyether-ether-ketone as the material of choice, compared to a removable partial denture made with a cobalt-chromium framework. In this case, it was possible to perceive that the use of computer-aided design and computer-aided manufacturing technology for the construction of a removable partial denture framework of polyether-ether-ketone resulted in a denture with adequate adaptation and good aesthetics. Patient satisfaction, comfort, retention, number of follow-up sessions, masticatory performance and quality of life were evaluated. Compared with the conventional denture, the polyether-ether-ketone framework denture provided better satisfaction and comfort. Both prostheses showed similar results in terms of masticatory performance and in terms of quality of life, however the polyether-ether-ketone framework denture showed better results. In conclusion, polyether-ether-ketone proved to be a viable material for making removable partial denture framework. However, controlled and randomized clinical trials are needed to demonstrate the benefits of this treatment as an alternative in relation to the conventional denture. |
publishDate |
2023 |
dc.date.none.fl_str_mv |
2023-02-22 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/57476 10.34119/bjhrv6n1-312 |
url |
https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/57476 |
identifier_str_mv |
10.34119/bjhrv6n1-312 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/57476/42019 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Brazilian Journals Publicações de Periódicos e Editora Ltda. |
publisher.none.fl_str_mv |
Brazilian Journals Publicações de Periódicos e Editora Ltda. |
dc.source.none.fl_str_mv |
Brazilian Journal of Health Review; Vol. 6 No. 1 (2023); 4027-4039 Brazilian Journal of Health Review; Vol. 6 Núm. 1 (2023); 4027-4039 Brazilian Journal of Health Review; v. 6 n. 1 (2023); 4027-4039 2595-6825 reponame:Brazilian Journal of Health Review instname:Federação das Indústrias do Estado do Paraná (FIEP) instacron:BJRH |
instname_str |
Federação das Indústrias do Estado do Paraná (FIEP) |
instacron_str |
BJRH |
institution |
BJRH |
reponame_str |
Brazilian Journal of Health Review |
collection |
Brazilian Journal of Health Review |
repository.name.fl_str_mv |
Brazilian Journal of Health Review - Federação das Indústrias do Estado do Paraná (FIEP) |
repository.mail.fl_str_mv |
|| brazilianjhr@gmail.com |
_version_ |
1797240027100479488 |