Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report

Detalhes bibliográficos
Autor(a) principal: Curinga, Míria Rafaelli Souza
Data de Publicação: 2023
Outros Autores: da Silva, Gabriel Gomes, Pereira, Ana Larisse Carneiro, de Freitas, Rodrigo Falcão Carvalho Porto, Carreiro, Adriana da Fonte Porto
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Health Review
Texto Completo: https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/57476
Resumo: The introduction of computer-aided design and computer-aided manufacturing in rehabilitation with removable partial denture, enabled the emergence of new methods of fabrication of the framework and materials. In view of this, polyether-ether-ketone appears as an alternative to Cobalt-Chromium, due to its aesthetic properties, high resistance and for being non-allergic. In this sense, the present study aimed to report a clinical case where the framework of a removable partial denture was manufactured from a digital workflow, using polyether-ether-ketone as the material of choice, compared to a removable partial denture made with a cobalt-chromium framework. In this case, it was possible to perceive that the use of computer-aided design and computer-aided manufacturing technology for the construction of a removable partial denture framework of polyether-ether-ketone resulted in a denture with adequate adaptation and good aesthetics. Patient satisfaction, comfort, retention, number of follow-up sessions, masticatory performance and quality of life were evaluated. Compared with the conventional denture, the polyether-ether-ketone framework denture provided better satisfaction and comfort. Both prostheses showed similar results in terms of masticatory performance and in terms of quality of life, however the polyether-ether-ketone framework denture showed better results. In conclusion, polyether-ether-ketone proved to be a viable material for making removable partial denture framework. However, controlled and randomized clinical trials are needed to demonstrate the benefits of this treatment as an alternative in relation to the conventional denture.
id BJRH-0_d9ade06f8e43ea9e91be091842e68116
oai_identifier_str oai:ojs2.ojs.brazilianjournals.com.br:article/57476
network_acronym_str BJRH-0
network_name_str Brazilian Journal of Health Review
repository_id_str
spelling Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case reportremovable partial denturebiomedical and dental materialspolymerstechnologycomputer-aided designThe introduction of computer-aided design and computer-aided manufacturing in rehabilitation with removable partial denture, enabled the emergence of new methods of fabrication of the framework and materials. In view of this, polyether-ether-ketone appears as an alternative to Cobalt-Chromium, due to its aesthetic properties, high resistance and for being non-allergic. In this sense, the present study aimed to report a clinical case where the framework of a removable partial denture was manufactured from a digital workflow, using polyether-ether-ketone as the material of choice, compared to a removable partial denture made with a cobalt-chromium framework. In this case, it was possible to perceive that the use of computer-aided design and computer-aided manufacturing technology for the construction of a removable partial denture framework of polyether-ether-ketone resulted in a denture with adequate adaptation and good aesthetics. Patient satisfaction, comfort, retention, number of follow-up sessions, masticatory performance and quality of life were evaluated. Compared with the conventional denture, the polyether-ether-ketone framework denture provided better satisfaction and comfort. Both prostheses showed similar results in terms of masticatory performance and in terms of quality of life, however the polyether-ether-ketone framework denture showed better results. In conclusion, polyether-ether-ketone proved to be a viable material for making removable partial denture framework. However, controlled and randomized clinical trials are needed to demonstrate the benefits of this treatment as an alternative in relation to the conventional denture.Brazilian Journals Publicações de Periódicos e Editora Ltda.2023-02-22info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/5747610.34119/bjhrv6n1-312Brazilian Journal of Health Review; Vol. 6 No. 1 (2023); 4027-4039Brazilian Journal of Health Review; Vol. 6 Núm. 1 (2023); 4027-4039Brazilian Journal of Health Review; v. 6 n. 1 (2023); 4027-40392595-6825reponame:Brazilian Journal of Health Reviewinstname:Federação das Indústrias do Estado do Paraná (FIEP)instacron:BJRHenghttps://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/57476/42019Curinga, Míria Rafaelli Souzada Silva, Gabriel GomesPereira, Ana Larisse Carneirode Freitas, Rodrigo Falcão Carvalho PortoCarreiro, Adriana da Fonte Portoinfo:eu-repo/semantics/openAccess2023-02-24T20:07:15Zoai:ojs2.ojs.brazilianjournals.com.br:article/57476Revistahttp://www.brazilianjournals.com/index.php/BJHR/indexPRIhttps://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/oai|| brazilianjhr@gmail.com2595-68252595-6825opendoar:2023-02-24T20:07:15Brazilian Journal of Health Review - Federação das Indústrias do Estado do Paraná (FIEP)false
dc.title.none.fl_str_mv Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report
title Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report
spellingShingle Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report
Curinga, Míria Rafaelli Souza
removable partial denture
biomedical and dental materials
polymers
technology
computer-aided design
title_short Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report
title_full Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report
title_fullStr Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report
title_full_unstemmed Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report
title_sort Fabrication of a removable partial denture of injectable poly (ether-ether-ketone) (PEEK) made partially by a digital workflow: case report
author Curinga, Míria Rafaelli Souza
author_facet Curinga, Míria Rafaelli Souza
da Silva, Gabriel Gomes
Pereira, Ana Larisse Carneiro
de Freitas, Rodrigo Falcão Carvalho Porto
Carreiro, Adriana da Fonte Porto
author_role author
author2 da Silva, Gabriel Gomes
Pereira, Ana Larisse Carneiro
de Freitas, Rodrigo Falcão Carvalho Porto
Carreiro, Adriana da Fonte Porto
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Curinga, Míria Rafaelli Souza
da Silva, Gabriel Gomes
Pereira, Ana Larisse Carneiro
de Freitas, Rodrigo Falcão Carvalho Porto
Carreiro, Adriana da Fonte Porto
dc.subject.por.fl_str_mv removable partial denture
biomedical and dental materials
polymers
technology
computer-aided design
topic removable partial denture
biomedical and dental materials
polymers
technology
computer-aided design
description The introduction of computer-aided design and computer-aided manufacturing in rehabilitation with removable partial denture, enabled the emergence of new methods of fabrication of the framework and materials. In view of this, polyether-ether-ketone appears as an alternative to Cobalt-Chromium, due to its aesthetic properties, high resistance and for being non-allergic. In this sense, the present study aimed to report a clinical case where the framework of a removable partial denture was manufactured from a digital workflow, using polyether-ether-ketone as the material of choice, compared to a removable partial denture made with a cobalt-chromium framework. In this case, it was possible to perceive that the use of computer-aided design and computer-aided manufacturing technology for the construction of a removable partial denture framework of polyether-ether-ketone resulted in a denture with adequate adaptation and good aesthetics. Patient satisfaction, comfort, retention, number of follow-up sessions, masticatory performance and quality of life were evaluated. Compared with the conventional denture, the polyether-ether-ketone framework denture provided better satisfaction and comfort. Both prostheses showed similar results in terms of masticatory performance and in terms of quality of life, however the polyether-ether-ketone framework denture showed better results. In conclusion, polyether-ether-ketone proved to be a viable material for making removable partial denture framework. However, controlled and randomized clinical trials are needed to demonstrate the benefits of this treatment as an alternative in relation to the conventional denture.
publishDate 2023
dc.date.none.fl_str_mv 2023-02-22
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/57476
10.34119/bjhrv6n1-312
url https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/57476
identifier_str_mv 10.34119/bjhrv6n1-312
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://ojs.brazilianjournals.com.br/ojs/index.php/BJHR/article/view/57476/42019
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Brazilian Journals Publicações de Periódicos e Editora Ltda.
publisher.none.fl_str_mv Brazilian Journals Publicações de Periódicos e Editora Ltda.
dc.source.none.fl_str_mv Brazilian Journal of Health Review; Vol. 6 No. 1 (2023); 4027-4039
Brazilian Journal of Health Review; Vol. 6 Núm. 1 (2023); 4027-4039
Brazilian Journal of Health Review; v. 6 n. 1 (2023); 4027-4039
2595-6825
reponame:Brazilian Journal of Health Review
instname:Federação das Indústrias do Estado do Paraná (FIEP)
instacron:BJRH
instname_str Federação das Indústrias do Estado do Paraná (FIEP)
instacron_str BJRH
institution BJRH
reponame_str Brazilian Journal of Health Review
collection Brazilian Journal of Health Review
repository.name.fl_str_mv Brazilian Journal of Health Review - Federação das Indústrias do Estado do Paraná (FIEP)
repository.mail.fl_str_mv || brazilianjhr@gmail.com
_version_ 1797240027100479488