Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies
Autor(a) principal: | |
---|---|
Data de Publicação: | 2010 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Infectious Diseases |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702010000100008 |
Resumo: | Dot-ELISA using the outer membrane complex antigens of Neisseria meningitidis as a target was standardized for rapid detection of meningococcal-specific antibodies in human serum. We investigated the level of meningococcal-specific IgG, IgA, and IgM in serum using dot-ELISA with outer membrane antigens prepared from Neisseria meningitidis serotype B:4.19:P1.15,3,7,9 (a strain isolated from a Brazilian epidemic). The dot-ELISA is based on the same principles as the standard ELISA and is useful for detection of anti-N. meningitidis B antibodies in serum of patients with meningococcal infections. For the assay, outer membrane complexes (OMCs) were absorbed by nitrocellulose membrane and blocked with a 5% skim milk solution. Serum samples were drawn upon hospital admission and during convalescence from patients with meningococcal septicemia, and single samples were drawn from uninfected controls. We retrospectively examined a total of 57 serum samples: 35 from patients infected with N. meningitidis B, 12 from patients infected with Haemophilus influenzae b, and 10 from health individuals. When performed at room temperature, dot-ELISA took approximately four hours to perform, and the optimum antigen concentration was 0.42 µg per dot. The specificity of IgG, IgM, and IgA demonstrates that dot-ELISA using OMCs from N. meningitidis B as a target is suitable for serologic verification of clinically suspected meningococcal disease in patients and for titer determination of antibodies produced during different phases of natural infection. Furthermore, the sensitivity of dot-ELISA was comparable to that of standard ELISA. Overall, dot-ELISA is simple to perform, rapid, and low cost. Further validation of the test as a screening tool is required. |
id |
BSID-1_329e41f2131ecb6a9a5f0b6adc742ccb |
---|---|
oai_identifier_str |
oai:scielo:S1413-86702010000100008 |
network_acronym_str |
BSID-1 |
network_name_str |
Brazilian Journal of Infectious Diseases |
repository_id_str |
|
spelling |
Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodiesNeisseria meningitidisdot-ELISAELISAantibodiesouter membrane complexDot-ELISA using the outer membrane complex antigens of Neisseria meningitidis as a target was standardized for rapid detection of meningococcal-specific antibodies in human serum. We investigated the level of meningococcal-specific IgG, IgA, and IgM in serum using dot-ELISA with outer membrane antigens prepared from Neisseria meningitidis serotype B:4.19:P1.15,3,7,9 (a strain isolated from a Brazilian epidemic). The dot-ELISA is based on the same principles as the standard ELISA and is useful for detection of anti-N. meningitidis B antibodies in serum of patients with meningococcal infections. For the assay, outer membrane complexes (OMCs) were absorbed by nitrocellulose membrane and blocked with a 5% skim milk solution. Serum samples were drawn upon hospital admission and during convalescence from patients with meningococcal septicemia, and single samples were drawn from uninfected controls. We retrospectively examined a total of 57 serum samples: 35 from patients infected with N. meningitidis B, 12 from patients infected with Haemophilus influenzae b, and 10 from health individuals. When performed at room temperature, dot-ELISA took approximately four hours to perform, and the optimum antigen concentration was 0.42 µg per dot. The specificity of IgG, IgM, and IgA demonstrates that dot-ELISA using OMCs from N. meningitidis B as a target is suitable for serologic verification of clinically suspected meningococcal disease in patients and for titer determination of antibodies produced during different phases of natural infection. Furthermore, the sensitivity of dot-ELISA was comparable to that of standard ELISA. Overall, dot-ELISA is simple to perform, rapid, and low cost. Further validation of the test as a screening tool is required.Brazilian Society of Infectious Diseases2010-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702010000100008Brazilian Journal of Infectious Diseases v.14 n.1 2010reponame:Brazilian Journal of Infectious Diseasesinstname:Brazilian Society of Infectious Diseases (BSID)instacron:BSID10.1590/S1413-86702010000100008info:eu-repo/semantics/openAccessBelo,Elza FTFarhat,Calil KGaspari,Elizabeth N Deeng2010-04-13T00:00:00Zoai:scielo:S1413-86702010000100008Revistahttps://www.bjid.org.br/https://old.scielo.br/oai/scielo-oai.phpbjid@bjid.org.br||lgoldani@ufrgs.br1678-43911413-8670opendoar:2010-04-13T00:00Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID)false |
dc.title.none.fl_str_mv |
Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies |
title |
Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies |
spellingShingle |
Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies Belo,Elza FT Neisseria meningitidis dot-ELISA ELISA antibodies outer membrane complex |
title_short |
Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies |
title_full |
Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies |
title_fullStr |
Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies |
title_full_unstemmed |
Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies |
title_sort |
Comparison of dot-ELISA and standard ELISA for detection of Neisseria meningitidis outer membrane complex-specific antibodies |
author |
Belo,Elza FT |
author_facet |
Belo,Elza FT Farhat,Calil K Gaspari,Elizabeth N De |
author_role |
author |
author2 |
Farhat,Calil K Gaspari,Elizabeth N De |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Belo,Elza FT Farhat,Calil K Gaspari,Elizabeth N De |
dc.subject.por.fl_str_mv |
Neisseria meningitidis dot-ELISA ELISA antibodies outer membrane complex |
topic |
Neisseria meningitidis dot-ELISA ELISA antibodies outer membrane complex |
description |
Dot-ELISA using the outer membrane complex antigens of Neisseria meningitidis as a target was standardized for rapid detection of meningococcal-specific antibodies in human serum. We investigated the level of meningococcal-specific IgG, IgA, and IgM in serum using dot-ELISA with outer membrane antigens prepared from Neisseria meningitidis serotype B:4.19:P1.15,3,7,9 (a strain isolated from a Brazilian epidemic). The dot-ELISA is based on the same principles as the standard ELISA and is useful for detection of anti-N. meningitidis B antibodies in serum of patients with meningococcal infections. For the assay, outer membrane complexes (OMCs) were absorbed by nitrocellulose membrane and blocked with a 5% skim milk solution. Serum samples were drawn upon hospital admission and during convalescence from patients with meningococcal septicemia, and single samples were drawn from uninfected controls. We retrospectively examined a total of 57 serum samples: 35 from patients infected with N. meningitidis B, 12 from patients infected with Haemophilus influenzae b, and 10 from health individuals. When performed at room temperature, dot-ELISA took approximately four hours to perform, and the optimum antigen concentration was 0.42 µg per dot. The specificity of IgG, IgM, and IgA demonstrates that dot-ELISA using OMCs from N. meningitidis B as a target is suitable for serologic verification of clinically suspected meningococcal disease in patients and for titer determination of antibodies produced during different phases of natural infection. Furthermore, the sensitivity of dot-ELISA was comparable to that of standard ELISA. Overall, dot-ELISA is simple to perform, rapid, and low cost. Further validation of the test as a screening tool is required. |
publishDate |
2010 |
dc.date.none.fl_str_mv |
2010-02-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702010000100008 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702010000100008 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1413-86702010000100008 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Brazilian Society of Infectious Diseases |
publisher.none.fl_str_mv |
Brazilian Society of Infectious Diseases |
dc.source.none.fl_str_mv |
Brazilian Journal of Infectious Diseases v.14 n.1 2010 reponame:Brazilian Journal of Infectious Diseases instname:Brazilian Society of Infectious Diseases (BSID) instacron:BSID |
instname_str |
Brazilian Society of Infectious Diseases (BSID) |
instacron_str |
BSID |
institution |
BSID |
reponame_str |
Brazilian Journal of Infectious Diseases |
collection |
Brazilian Journal of Infectious Diseases |
repository.name.fl_str_mv |
Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID) |
repository.mail.fl_str_mv |
bjid@bjid.org.br||lgoldani@ufrgs.br |
_version_ |
1754209241115131904 |