Resumo: Although the introduction of alcohol based products have increased compliance with hand hygiene in intensive care units (ICU), no comparative studies with other products in the same unit and in the same period have been conducted. We performed a two-month-observational prospective study comparing three units in an adult ICU, according to hand hygiene practices (chlorhexidine alone-unit A, both chlorhexidine and alcohol gel-unit B, and alcohol gel alone-unit C, respectively). Opportunities for hand hygiene were considered according to an institutional guideline. Patients were randomly allocated in the 3 units and data on hand hygiene compliance was collected without the knowledge of the health care staff. TISS score (used for measuring patient complexity) was similar between the three different units. Overall compliance with hand hygiene was 46.7% (659/1410). Compliance was significantly higher after patient care in unit A when compared to units B and C. On the other hand, compliance was significantly higher only between units A (32.1%) and C (23.1%) before patient care (p=0.02). Higher compliance rates were observed for general opportunities for hand hygiene (patient bathing, vital sign controls, etc), while very low compliance rates were observed for opportunities related to skin and gastroenteral care. One of the reasons for not using alcohol gel according to health care workers was the necessity for water contact (35.3%, 12/20). Although the use of alcohol based products is now the standard practice for hand hygiene the abrupt abolition of hand hygiene with traditional products may not be recommended for specific services.
id BSID-1_6b8bd898b6523d14fc7f6a72d4195673
oai_identifier_str oai:scielo:S1413-86702009000500003
network_acronym_str BSID-1
network_name_str Brazilian Journal of Infectious Diseases
repository_id_str
spelling Low compliance with alcohol gel compared with chlorhexidine for hand hygiene in ICU patients: results of an alcohol gel implementation programAlcohol gel and chlorhexidineHand washingICUAlthough the introduction of alcohol based products have increased compliance with hand hygiene in intensive care units (ICU), no comparative studies with other products in the same unit and in the same period have been conducted. We performed a two-month-observational prospective study comparing three units in an adult ICU, according to hand hygiene practices (chlorhexidine alone-unit A, both chlorhexidine and alcohol gel-unit B, and alcohol gel alone-unit C, respectively). Opportunities for hand hygiene were considered according to an institutional guideline. Patients were randomly allocated in the 3 units and data on hand hygiene compliance was collected without the knowledge of the health care staff. TISS score (used for measuring patient complexity) was similar between the three different units. Overall compliance with hand hygiene was 46.7% (659/1410). Compliance was significantly higher after patient care in unit A when compared to units B and C. On the other hand, compliance was significantly higher only between units A (32.1%) and C (23.1%) before patient care (p=0.02). Higher compliance rates were observed for general opportunities for hand hygiene (patient bathing, vital sign controls, etc), while very low compliance rates were observed for opportunities related to skin and gastroenteral care. One of the reasons for not using alcohol gel according to health care workers was the necessity for water contact (35.3%, 12/20). Although the use of alcohol based products is now the standard practice for hand hygiene the abrupt abolition of hand hygiene with traditional products may not be recommended for specific services.Brazilian Society of Infectious Diseases2009-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702009000500003Brazilian Journal of Infectious Diseases v.13 n.5 2009reponame:Brazilian Journal of Infectious Diseasesinstname:Brazilian Society of Infectious Diseases (BSID)instacron:BSID10.1590/S1413-86702009000500003info:eu-repo/semantics/openAccessCamargo,Luis Fernando AranhaMarra,Alexandre RodriguesSilva,Cláudia ValloneLaselva,Cláudia ReginaMoura Junior,Denis FariaCal,Ruy Guilherme G.Yamashita,Maria AparecidaKnobel,Eliaseng2010-04-16T00:00:00Zoai:scielo:S1413-86702009000500003Revistahttps://www.bjid.org.br/https://old.scielo.br/oai/scielo-oai.phpbjid@bjid.org.br||lgoldani@ufrgs.br1678-43911413-8670opendoar:2010-04-16T00:00Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID)false
dc.title.none.fl_str_mv Low compliance with alcohol gel compared with chlorhexidine for hand hygiene in ICU patients: results of an alcohol gel implementation program
title Low compliance with alcohol gel compared with chlorhexidine for hand hygiene in ICU patients: results of an alcohol gel implementation program
spellingShingle Low compliance with alcohol gel compared with chlorhexidine for hand hygiene in ICU patients: results of an alcohol gel implementation program
Camargo,Luis Fernando Aranha
Alcohol gel and chlorhexidine
Hand washing
ICU
title_short Low compliance with alcohol gel compared with chlorhexidine for hand hygiene in ICU patients: results of an alcohol gel implementation program
title_full Low compliance with alcohol gel compared with chlorhexidine for hand hygiene in ICU patients: results of an alcohol gel implementation program
title_fullStr Low compliance with alcohol gel compared with chlorhexidine for hand hygiene in ICU patients: results of an alcohol gel implementation program
title_full_unstemmed Low compliance with alcohol gel compared with chlorhexidine for hand hygiene in ICU patients: results of an alcohol gel implementation program
title_sort Low compliance with alcohol gel compared with chlorhexidine for hand hygiene in ICU patients: results of an alcohol gel implementation program
author Camargo,Luis Fernando Aranha
author_facet Camargo,Luis Fernando Aranha
Marra,Alexandre Rodrigues
Silva,Cláudia Vallone
Laselva,Cláudia Regina
Moura Junior,Denis Faria
Cal,Ruy Guilherme G.
Yamashita,Maria Aparecida
Knobel,Elias
author_role author
author2 Marra,Alexandre Rodrigues
Silva,Cláudia Vallone
Laselva,Cláudia Regina
Moura Junior,Denis Faria
Cal,Ruy Guilherme G.
Yamashita,Maria Aparecida
Knobel,Elias
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Camargo,Luis Fernando Aranha
Marra,Alexandre Rodrigues
Silva,Cláudia Vallone
Laselva,Cláudia Regina
Moura Junior,Denis Faria
Cal,Ruy Guilherme G.
Yamashita,Maria Aparecida
Knobel,Elias
dc.subject.por.fl_str_mv Alcohol gel and chlorhexidine
Hand washing
ICU
topic Alcohol gel and chlorhexidine
Hand washing
ICU
description Although the introduction of alcohol based products have increased compliance with hand hygiene in intensive care units (ICU), no comparative studies with other products in the same unit and in the same period have been conducted. We performed a two-month-observational prospective study comparing three units in an adult ICU, according to hand hygiene practices (chlorhexidine alone-unit A, both chlorhexidine and alcohol gel-unit B, and alcohol gel alone-unit C, respectively). Opportunities for hand hygiene were considered according to an institutional guideline. Patients were randomly allocated in the 3 units and data on hand hygiene compliance was collected without the knowledge of the health care staff. TISS score (used for measuring patient complexity) was similar between the three different units. Overall compliance with hand hygiene was 46.7% (659/1410). Compliance was significantly higher after patient care in unit A when compared to units B and C. On the other hand, compliance was significantly higher only between units A (32.1%) and C (23.1%) before patient care (p=0.02). Higher compliance rates were observed for general opportunities for hand hygiene (patient bathing, vital sign controls, etc), while very low compliance rates were observed for opportunities related to skin and gastroenteral care. One of the reasons for not using alcohol gel according to health care workers was the necessity for water contact (35.3%, 12/20). Although the use of alcohol based products is now the standard practice for hand hygiene the abrupt abolition of hand hygiene with traditional products may not be recommended for specific services.
publishDate 2009
dc.date.none.fl_str_mv 2009-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702009000500003
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702009000500003
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1413-86702009000500003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Brazilian Society of Infectious Diseases
publisher.none.fl_str_mv Brazilian Society of Infectious Diseases
dc.source.none.fl_str_mv Brazilian Journal of Infectious Diseases v.13 n.5 2009
reponame:Brazilian Journal of Infectious Diseases
instname:Brazilian Society of Infectious Diseases (BSID)
instacron:BSID
instname_str Brazilian Society of Infectious Diseases (BSID)
instacron_str BSID
institution BSID
reponame_str Brazilian Journal of Infectious Diseases
collection Brazilian Journal of Infectious Diseases
repository.name.fl_str_mv Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID)
repository.mail.fl_str_mv bjid@bjid.org.br||lgoldani@ufrgs.br
_version_ 1754209241063751680