Comparison of multiplex-PCR and antigen detection for differential diagnosis of Entamoeba histolytica

Detalhes bibliográficos
Autor(a) principal: Santos,Helena Lúcia Carneiro
Data de Publicação: 2007
Outros Autores: Peralta,Regina Helena Saramago, Macedo,Heloisa Werneck de, Barreto,Magali Gonçalves Muniz, Peralta,José Mauro
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Infectious Diseases
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702007000300013
Resumo: Amebiasis is an infection caused by Entamoeba histolytica. However, differentiation between E. histolytica and Entamoeba dispar, which are morphologically identical species, is essential for treatment decision, precaution of the invasive disease and public health. The purpose of the present study was to evaluate a Multiplex -PCR for detection and differentiation of E. histolytica from E. dispar from fresh stool samples in comparison with the coproantigen commercial ELISA. Microscopic examination of stools using the Coprotest method, detection of stool antigen by enzyme-linked immunosorbent assay kit and a home made Multiplex-PCR, were used for the diagnosis of amoebiasis infection. Analysis of the 127 stools samples by microscopy examination demonstrated that only 27 (21%) samples were positive for E. histolytica/E. dispar complex. Among these stool samples, 11 were positive by Multiplex-PCR, with nine presenting the diagnostic fragment characteristic of E. dispar (96 bp) and two presenting diagnostic fragment of E. histolytica (132 bp). Among negative samples detected by microscopic examination, three positive samples for E. dispar and one positive for E. histolytica by Multiplex-PCR was observed. This denotes a low sensibility of microscopic examination when a single stool sample is analyzed. Assay for detection of E. histolytica antigen was concordant with multiplex-PCR in relation to E. histolytica. Statistical analysis comparing the sensibility tests was not done because of the low number of E. histolytica cases. The results demonstrate the importance of the specific techniques use for the differentiation between E. histolytica and E. dispar.
id BSID-1_aab0ec1958089935dabc04aa2d362b9e
oai_identifier_str oai:scielo:S1413-86702007000300013
network_acronym_str BSID-1
network_name_str Brazilian Journal of Infectious Diseases
repository_id_str
spelling Comparison of multiplex-PCR and antigen detection for differential diagnosis of Entamoeba histolyticaMultiplex-PCREntamoeba histolyticaamebiasisAmebiasis is an infection caused by Entamoeba histolytica. However, differentiation between E. histolytica and Entamoeba dispar, which are morphologically identical species, is essential for treatment decision, precaution of the invasive disease and public health. The purpose of the present study was to evaluate a Multiplex -PCR for detection and differentiation of E. histolytica from E. dispar from fresh stool samples in comparison with the coproantigen commercial ELISA. Microscopic examination of stools using the Coprotest method, detection of stool antigen by enzyme-linked immunosorbent assay kit and a home made Multiplex-PCR, were used for the diagnosis of amoebiasis infection. Analysis of the 127 stools samples by microscopy examination demonstrated that only 27 (21%) samples were positive for E. histolytica/E. dispar complex. Among these stool samples, 11 were positive by Multiplex-PCR, with nine presenting the diagnostic fragment characteristic of E. dispar (96 bp) and two presenting diagnostic fragment of E. histolytica (132 bp). Among negative samples detected by microscopic examination, three positive samples for E. dispar and one positive for E. histolytica by Multiplex-PCR was observed. This denotes a low sensibility of microscopic examination when a single stool sample is analyzed. Assay for detection of E. histolytica antigen was concordant with multiplex-PCR in relation to E. histolytica. Statistical analysis comparing the sensibility tests was not done because of the low number of E. histolytica cases. The results demonstrate the importance of the specific techniques use for the differentiation between E. histolytica and E. dispar.Brazilian Society of Infectious Diseases2007-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702007000300013Brazilian Journal of Infectious Diseases v.11 n.3 2007reponame:Brazilian Journal of Infectious Diseasesinstname:Brazilian Society of Infectious Diseases (BSID)instacron:BSID10.1590/S1413-86702007000300013info:eu-repo/semantics/openAccessSantos,Helena Lúcia CarneiroPeralta,Regina Helena SaramagoMacedo,Heloisa Werneck deBarreto,Magali Gonçalves MunizPeralta,José Mauroeng2007-07-30T00:00:00Zoai:scielo:S1413-86702007000300013Revistahttps://www.bjid.org.br/https://old.scielo.br/oai/scielo-oai.phpbjid@bjid.org.br||lgoldani@ufrgs.br1678-43911413-8670opendoar:2007-07-30T00:00Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID)false
dc.title.none.fl_str_mv Comparison of multiplex-PCR and antigen detection for differential diagnosis of Entamoeba histolytica
title Comparison of multiplex-PCR and antigen detection for differential diagnosis of Entamoeba histolytica
spellingShingle Comparison of multiplex-PCR and antigen detection for differential diagnosis of Entamoeba histolytica
Santos,Helena Lúcia Carneiro
Multiplex-PCR
Entamoeba histolytica
amebiasis
title_short Comparison of multiplex-PCR and antigen detection for differential diagnosis of Entamoeba histolytica
title_full Comparison of multiplex-PCR and antigen detection for differential diagnosis of Entamoeba histolytica
title_fullStr Comparison of multiplex-PCR and antigen detection for differential diagnosis of Entamoeba histolytica
title_full_unstemmed Comparison of multiplex-PCR and antigen detection for differential diagnosis of Entamoeba histolytica
title_sort Comparison of multiplex-PCR and antigen detection for differential diagnosis of Entamoeba histolytica
author Santos,Helena Lúcia Carneiro
author_facet Santos,Helena Lúcia Carneiro
Peralta,Regina Helena Saramago
Macedo,Heloisa Werneck de
Barreto,Magali Gonçalves Muniz
Peralta,José Mauro
author_role author
author2 Peralta,Regina Helena Saramago
Macedo,Heloisa Werneck de
Barreto,Magali Gonçalves Muniz
Peralta,José Mauro
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Santos,Helena Lúcia Carneiro
Peralta,Regina Helena Saramago
Macedo,Heloisa Werneck de
Barreto,Magali Gonçalves Muniz
Peralta,José Mauro
dc.subject.por.fl_str_mv Multiplex-PCR
Entamoeba histolytica
amebiasis
topic Multiplex-PCR
Entamoeba histolytica
amebiasis
description Amebiasis is an infection caused by Entamoeba histolytica. However, differentiation between E. histolytica and Entamoeba dispar, which are morphologically identical species, is essential for treatment decision, precaution of the invasive disease and public health. The purpose of the present study was to evaluate a Multiplex -PCR for detection and differentiation of E. histolytica from E. dispar from fresh stool samples in comparison with the coproantigen commercial ELISA. Microscopic examination of stools using the Coprotest method, detection of stool antigen by enzyme-linked immunosorbent assay kit and a home made Multiplex-PCR, were used for the diagnosis of amoebiasis infection. Analysis of the 127 stools samples by microscopy examination demonstrated that only 27 (21%) samples were positive for E. histolytica/E. dispar complex. Among these stool samples, 11 were positive by Multiplex-PCR, with nine presenting the diagnostic fragment characteristic of E. dispar (96 bp) and two presenting diagnostic fragment of E. histolytica (132 bp). Among negative samples detected by microscopic examination, three positive samples for E. dispar and one positive for E. histolytica by Multiplex-PCR was observed. This denotes a low sensibility of microscopic examination when a single stool sample is analyzed. Assay for detection of E. histolytica antigen was concordant with multiplex-PCR in relation to E. histolytica. Statistical analysis comparing the sensibility tests was not done because of the low number of E. histolytica cases. The results demonstrate the importance of the specific techniques use for the differentiation between E. histolytica and E. dispar.
publishDate 2007
dc.date.none.fl_str_mv 2007-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702007000300013
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702007000300013
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1413-86702007000300013
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Brazilian Society of Infectious Diseases
publisher.none.fl_str_mv Brazilian Society of Infectious Diseases
dc.source.none.fl_str_mv Brazilian Journal of Infectious Diseases v.11 n.3 2007
reponame:Brazilian Journal of Infectious Diseases
instname:Brazilian Society of Infectious Diseases (BSID)
instacron:BSID
instname_str Brazilian Society of Infectious Diseases (BSID)
instacron_str BSID
institution BSID
reponame_str Brazilian Journal of Infectious Diseases
collection Brazilian Journal of Infectious Diseases
repository.name.fl_str_mv Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID)
repository.mail.fl_str_mv bjid@bjid.org.br||lgoldani@ufrgs.br
_version_ 1754209239873617920