Comparison between the jugular and subclavian vein as insertion site for central venous catheters: microbiological aspects and risk factors for colonization and infection
Autor(a) principal: | |
---|---|
Data de Publicação: | 2003 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Journal of Infectious Diseases |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702003000200008 |
Resumo: | Bacterial counts were made of catheter insertion site and of catheter tips to help determine risk factors associated with catheterization of the jugular and subclavian veins. Among the 116 patients included in this study, 69% had central venous catheters (CVC) in the subclavian vein. Seven or more days catheterization (p=0.001) and >3 invasive devices (p=0.01) were infection risk factors associated with catheterization of the jugular vein. More than half of the patients presented high colony counts at the insertion site (>200 CFU/20 cm²) and 27% of the catheter tips were contaminated. The risk factors associated with contaminated catheter tips were >14 days hospital stay (p=0.02), >7 days catheterization (p=0.01) and antibiotic therapy (p=0.04). Coagulase-negative staphylococci (CoNS) and Staphylococcus aureus were the most common microorganisms at the insertion site (78%) and in the catheter tip (94%). Five patients presented sepsis (4.1%), four caused by Staphylococci and one by GNB. Twelve patients had the same microorganisms at the insertion site and catheter tip. We found a high prevalence of ORSA (62.5%) and ORCoNS (57.1%) in catheter tips. The high counts of staphylococci, including ORSA and ORCoNS, at the insertion site, and the significant association of this colonization with catheter tip contamination, indicate that the skin is an important reservoir of microorganisms associated with catheter-related bloodstream infection (CR-BSI). Health professionals should be aware of this potential source of infection at the CVC insertion site. |
id |
BSID-1_e9375db5579773da633b3cb09f68f598 |
---|---|
oai_identifier_str |
oai:scielo:S1413-86702003000200008 |
network_acronym_str |
BSID-1 |
network_name_str |
Brazilian Journal of Infectious Diseases |
repository_id_str |
|
spelling |
Comparison between the jugular and subclavian vein as insertion site for central venous catheters: microbiological aspects and risk factors for colonization and infectionCVCrisk factorCR-BSIORSAORCoNSBacterial counts were made of catheter insertion site and of catheter tips to help determine risk factors associated with catheterization of the jugular and subclavian veins. Among the 116 patients included in this study, 69% had central venous catheters (CVC) in the subclavian vein. Seven or more days catheterization (p=0.001) and >3 invasive devices (p=0.01) were infection risk factors associated with catheterization of the jugular vein. More than half of the patients presented high colony counts at the insertion site (>200 CFU/20 cm²) and 27% of the catheter tips were contaminated. The risk factors associated with contaminated catheter tips were >14 days hospital stay (p=0.02), >7 days catheterization (p=0.01) and antibiotic therapy (p=0.04). Coagulase-negative staphylococci (CoNS) and Staphylococcus aureus were the most common microorganisms at the insertion site (78%) and in the catheter tip (94%). Five patients presented sepsis (4.1%), four caused by Staphylococci and one by GNB. Twelve patients had the same microorganisms at the insertion site and catheter tip. We found a high prevalence of ORSA (62.5%) and ORCoNS (57.1%) in catheter tips. The high counts of staphylococci, including ORSA and ORCoNS, at the insertion site, and the significant association of this colonization with catheter tip contamination, indicate that the skin is an important reservoir of microorganisms associated with catheter-related bloodstream infection (CR-BSI). Health professionals should be aware of this potential source of infection at the CVC insertion site.Brazilian Society of Infectious Diseases2003-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702003000200008Brazilian Journal of Infectious Diseases v.7 n.2 2003reponame:Brazilian Journal of Infectious Diseasesinstname:Brazilian Society of Infectious Diseases (BSID)instacron:BSID10.1590/S1413-86702003000200008info:eu-repo/semantics/openAccessSadoyama,GeraldoGontijo Filho,Paulo Pintoeng2003-11-19T00:00:00Zoai:scielo:S1413-86702003000200008Revistahttps://www.bjid.org.br/https://old.scielo.br/oai/scielo-oai.phpbjid@bjid.org.br||lgoldani@ufrgs.br1678-43911413-8670opendoar:2003-11-19T00:00Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID)false |
dc.title.none.fl_str_mv |
Comparison between the jugular and subclavian vein as insertion site for central venous catheters: microbiological aspects and risk factors for colonization and infection |
title |
Comparison between the jugular and subclavian vein as insertion site for central venous catheters: microbiological aspects and risk factors for colonization and infection |
spellingShingle |
Comparison between the jugular and subclavian vein as insertion site for central venous catheters: microbiological aspects and risk factors for colonization and infection Sadoyama,Geraldo CVC risk factor CR-BSI ORSA ORCoNS |
title_short |
Comparison between the jugular and subclavian vein as insertion site for central venous catheters: microbiological aspects and risk factors for colonization and infection |
title_full |
Comparison between the jugular and subclavian vein as insertion site for central venous catheters: microbiological aspects and risk factors for colonization and infection |
title_fullStr |
Comparison between the jugular and subclavian vein as insertion site for central venous catheters: microbiological aspects and risk factors for colonization and infection |
title_full_unstemmed |
Comparison between the jugular and subclavian vein as insertion site for central venous catheters: microbiological aspects and risk factors for colonization and infection |
title_sort |
Comparison between the jugular and subclavian vein as insertion site for central venous catheters: microbiological aspects and risk factors for colonization and infection |
author |
Sadoyama,Geraldo |
author_facet |
Sadoyama,Geraldo Gontijo Filho,Paulo Pinto |
author_role |
author |
author2 |
Gontijo Filho,Paulo Pinto |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Sadoyama,Geraldo Gontijo Filho,Paulo Pinto |
dc.subject.por.fl_str_mv |
CVC risk factor CR-BSI ORSA ORCoNS |
topic |
CVC risk factor CR-BSI ORSA ORCoNS |
description |
Bacterial counts were made of catheter insertion site and of catheter tips to help determine risk factors associated with catheterization of the jugular and subclavian veins. Among the 116 patients included in this study, 69% had central venous catheters (CVC) in the subclavian vein. Seven or more days catheterization (p=0.001) and >3 invasive devices (p=0.01) were infection risk factors associated with catheterization of the jugular vein. More than half of the patients presented high colony counts at the insertion site (>200 CFU/20 cm²) and 27% of the catheter tips were contaminated. The risk factors associated with contaminated catheter tips were >14 days hospital stay (p=0.02), >7 days catheterization (p=0.01) and antibiotic therapy (p=0.04). Coagulase-negative staphylococci (CoNS) and Staphylococcus aureus were the most common microorganisms at the insertion site (78%) and in the catheter tip (94%). Five patients presented sepsis (4.1%), four caused by Staphylococci and one by GNB. Twelve patients had the same microorganisms at the insertion site and catheter tip. We found a high prevalence of ORSA (62.5%) and ORCoNS (57.1%) in catheter tips. The high counts of staphylococci, including ORSA and ORCoNS, at the insertion site, and the significant association of this colonization with catheter tip contamination, indicate that the skin is an important reservoir of microorganisms associated with catheter-related bloodstream infection (CR-BSI). Health professionals should be aware of this potential source of infection at the CVC insertion site. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702003000200008 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-86702003000200008 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1413-86702003000200008 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Brazilian Society of Infectious Diseases |
publisher.none.fl_str_mv |
Brazilian Society of Infectious Diseases |
dc.source.none.fl_str_mv |
Brazilian Journal of Infectious Diseases v.7 n.2 2003 reponame:Brazilian Journal of Infectious Diseases instname:Brazilian Society of Infectious Diseases (BSID) instacron:BSID |
instname_str |
Brazilian Society of Infectious Diseases (BSID) |
instacron_str |
BSID |
institution |
BSID |
reponame_str |
Brazilian Journal of Infectious Diseases |
collection |
Brazilian Journal of Infectious Diseases |
repository.name.fl_str_mv |
Brazilian Journal of Infectious Diseases - Brazilian Society of Infectious Diseases (BSID) |
repository.mail.fl_str_mv |
bjid@bjid.org.br||lgoldani@ufrgs.br |
_version_ |
1754209238600646656 |