Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | |
Tipo de documento: | Artigo |
Título da fonte: | Repositório da Produção Científica e Intelectual da Unicamp |
Texto Completo: | https://hdl.handle.net/20.500.12733/1665504 |
Resumo: | Abstract: The Phase I upgrade of the CMS Hadron Endcap Calorimeters consists of new photodetectors (Silicon Photomultipliers in place of Hybrid Photo-Diodes) and front-end electronics. The upgrade will eliminate the noise and the calibration drift of the Hybrid Photo-Diodes and enable the mitigation of the radiation damage of the scintillators and the wavelength shifting fibers with a larger spectral acceptance of the Silicon Photomultipliers. The upgrade also includes increased longitudinal segmentation of the calorimeter readout, which allows pile-up mitigation and recalibration due to depth-dependent radiation damage. As a realistic operational test, the responses of the Hadron Endcap Calorimeter wedges were calibrated with a Co-60 radioactive source with upgrade electronics. The test successfully established the procedure for future source calibrations of the Hadron Endcap Calorimeters. Here we describe the instrumentation details and the operational experiences related to the sourcing test |
id |
CAMP_716358481faef78d721f59e77727a36b |
---|---|
oai_identifier_str |
oai:https://www.repositorio.unicamp.br/:1217272 |
network_acronym_str |
CAMP |
network_name_str |
Repositório da Produção Científica e Intelectual da Unicamp |
repository_id_str |
|
spelling |
Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronicsDetectoresCalorímetrosDetectorsCalorimetersArtigo originalDetector alignment and calibration methods (Lasers, sources, particle-beams)Calorimeter methodsAbstract: The Phase I upgrade of the CMS Hadron Endcap Calorimeters consists of new photodetectors (Silicon Photomultipliers in place of Hybrid Photo-Diodes) and front-end electronics. The upgrade will eliminate the noise and the calibration drift of the Hybrid Photo-Diodes and enable the mitigation of the radiation damage of the scintillators and the wavelength shifting fibers with a larger spectral acceptance of the Silicon Photomultipliers. The upgrade also includes increased longitudinal segmentation of the calorimeter readout, which allows pile-up mitigation and recalibration due to depth-dependent radiation damage. As a realistic operational test, the responses of the Hadron Endcap Calorimeter wedges were calibrated with a Co-60 radioactive source with upgrade electronics. The test successfully established the procedure for future source calibrations of the Hadron Endcap Calorimeters. Here we describe the instrumentation details and the operational experiences related to the sourcing testAbertoUNIVERSIDADE ESTADUAL DE CAMPINASChinellato, José Augusto, 1950-Manganote, Edmilson José Tonelli, 1962-2017info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.12733/1665504CHINELLATO, José Augusto; MANGANOTE, Edmilson José Tonelli. Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics. Journal of instrumentation. Bristol : Institute of Physics Publishing, 2017. Vol. 12 (Dec., 2017), n. art. P12034, p. 1-17. Disponível em: https://hdl.handle.net/20.500.12733/1665504. Acesso em: 24 mai. 2023.Inglêshttps://repositorio.unicamp.br/acervo/detalhe/1217272reponame:Repositório da Produção Científica e Intelectual da Unicampinstname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPinfo:eu-repo/semantics/openAccess2022-05-17T18:54:05Zoai:https://www.repositorio.unicamp.br/:1217272Repositório InstitucionalPUBhttp://repositorio.unicamp.br/oai/requestreposip@unicamp.bropendoar:2022-05-17T18:54:05Repositório da Produção Científica e Intelectual da Unicamp - Universidade Estadual de Campinas (UNICAMP)false |
dc.title.none.fl_str_mv |
Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics |
title |
Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics |
spellingShingle |
Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics Chinellato, José Augusto, 1950- Detectores Calorímetros Detectors Calorimeters Artigo original Detector alignment and calibration methods (Lasers, sources, particle-beams) Calorimeter methods |
title_short |
Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics |
title_full |
Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics |
title_fullStr |
Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics |
title_full_unstemmed |
Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics |
title_sort |
Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics |
author |
Chinellato, José Augusto, 1950- |
author_facet |
Chinellato, José Augusto, 1950- Manganote, Edmilson José Tonelli, 1962- |
author_role |
author |
author2 |
Manganote, Edmilson José Tonelli, 1962- |
author2_role |
author |
dc.contributor.none.fl_str_mv |
UNIVERSIDADE ESTADUAL DE CAMPINAS |
dc.contributor.author.fl_str_mv |
Chinellato, José Augusto, 1950- Manganote, Edmilson José Tonelli, 1962- |
dc.subject.por.fl_str_mv |
Detectores Calorímetros Detectors Calorimeters Artigo original Detector alignment and calibration methods (Lasers, sources, particle-beams) Calorimeter methods |
topic |
Detectores Calorímetros Detectors Calorimeters Artigo original Detector alignment and calibration methods (Lasers, sources, particle-beams) Calorimeter methods |
description |
Abstract: The Phase I upgrade of the CMS Hadron Endcap Calorimeters consists of new photodetectors (Silicon Photomultipliers in place of Hybrid Photo-Diodes) and front-end electronics. The upgrade will eliminate the noise and the calibration drift of the Hybrid Photo-Diodes and enable the mitigation of the radiation damage of the scintillators and the wavelength shifting fibers with a larger spectral acceptance of the Silicon Photomultipliers. The upgrade also includes increased longitudinal segmentation of the calorimeter readout, which allows pile-up mitigation and recalibration due to depth-dependent radiation damage. As a realistic operational test, the responses of the Hadron Endcap Calorimeter wedges were calibrated with a Co-60 radioactive source with upgrade electronics. The test successfully established the procedure for future source calibrations of the Hadron Endcap Calorimeters. Here we describe the instrumentation details and the operational experiences related to the sourcing test |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/20.500.12733/1665504 CHINELLATO, José Augusto; MANGANOTE, Edmilson José Tonelli. Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics. Journal of instrumentation. Bristol : Institute of Physics Publishing, 2017. Vol. 12 (Dec., 2017), n. art. P12034, p. 1-17. Disponível em: https://hdl.handle.net/20.500.12733/1665504. Acesso em: 24 mai. 2023. |
url |
https://hdl.handle.net/20.500.12733/1665504 |
identifier_str_mv |
CHINELLATO, José Augusto; MANGANOTE, Edmilson José Tonelli. Radioactive source calibration test of the CMS Hadron Endcap Calorimeter test wedge with Phase I upgrade electronics. Journal of instrumentation. Bristol : Institute of Physics Publishing, 2017. Vol. 12 (Dec., 2017), n. art. P12034, p. 1-17. Disponível em: https://hdl.handle.net/20.500.12733/1665504. Acesso em: 24 mai. 2023. |
dc.language.iso.fl_str_mv |
Inglês |
language_invalid_str_mv |
Inglês |
dc.relation.none.fl_str_mv |
https://repositorio.unicamp.br/acervo/detalhe/1217272 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositório da Produção Científica e Intelectual da Unicamp instname:Universidade Estadual de Campinas (UNICAMP) instacron:UNICAMP |
instname_str |
Universidade Estadual de Campinas (UNICAMP) |
instacron_str |
UNICAMP |
institution |
UNICAMP |
reponame_str |
Repositório da Produção Científica e Intelectual da Unicamp |
collection |
Repositório da Produção Científica e Intelectual da Unicamp |
repository.name.fl_str_mv |
Repositório da Produção Científica e Intelectual da Unicamp - Universidade Estadual de Campinas (UNICAMP) |
repository.mail.fl_str_mv |
reposip@unicamp.br |
_version_ |
1766887307549343744 |