IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?

Detalhes bibliográficos
Autor(a) principal: ARDENGH,José Celso
Data de Publicação: 2020
Outros Autores: BRUNALDI,Vitor Ottoboni, BRUNALDI,Mariângela Ottoboni, GASPAR,Alberto Facuri, LOPES-JÚNIOR,Jorge Resende, SANKARANKUTTY,Ajith Kumar, KEMP,Rafael, SANTOS,José Sebastião dos
Tipo de documento: Artigo
Idioma: eng
Título da fonte: ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-67202020000400305
Resumo: ABSTRACT Background: It is important to obtain representative histological samples of solid biliopancreatic lesions without a clear indication for resection. The role of new needles in such task is yet to be determined. Aim: To compare performance assessment between 20G double fine needle biopsy (FNB) and conventional 22G fine needle aspiration (FNA) needles for endoscopic ultrasound (EUS)-guided biopsy. Methods: This prospective study examined 20 patients who underwent the random puncture of solid pancreatic lesions with both needles and the analysis of tissue samples by a single pathologist. Results: The ProCore 20G FNB needle provided more adequate tissue samples (16 vs. 9, p=0.039) with better cellularity quantitative scores (11 vs. 5, p=0.002) and larger diameter of the histological sample (1.51±1.3 mm vs. 0.94±0.55 mm, p=0.032) than the 22G needle. The technical success, puncture difficulty, and sample bleeding were similar between groups. The sensitivity, specificity, and diagnostic accuracy were 88.9%, 100%, and 90% and 77.8%, 100%, and 78.9% for the 20G and 22G needles, respectively. Conclusions: The samples obtained with the ProCore 20G FNB showed better histological parameters; although there was no difference in the diagnostic performance between the two needles, these findings may improve pathologist performance.
id CBCD-1_bf73897043aad7d8dfe728bf36e57bec
oai_identifier_str oai:scielo:S0102-67202020000400305
network_acronym_str CBCD-1
network_name_str ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
repository_id_str
spelling IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?DiagnosisEndoscopic UltrasoundFine-Needle aspiration biopsyFine-needle biopsyPancreatic cancerABSTRACT Background: It is important to obtain representative histological samples of solid biliopancreatic lesions without a clear indication for resection. The role of new needles in such task is yet to be determined. Aim: To compare performance assessment between 20G double fine needle biopsy (FNB) and conventional 22G fine needle aspiration (FNA) needles for endoscopic ultrasound (EUS)-guided biopsy. Methods: This prospective study examined 20 patients who underwent the random puncture of solid pancreatic lesions with both needles and the analysis of tissue samples by a single pathologist. Results: The ProCore 20G FNB needle provided more adequate tissue samples (16 vs. 9, p=0.039) with better cellularity quantitative scores (11 vs. 5, p=0.002) and larger diameter of the histological sample (1.51±1.3 mm vs. 0.94±0.55 mm, p=0.032) than the 22G needle. The technical success, puncture difficulty, and sample bleeding were similar between groups. The sensitivity, specificity, and diagnostic accuracy were 88.9%, 100%, and 90% and 77.8%, 100%, and 78.9% for the 20G and 22G needles, respectively. Conclusions: The samples obtained with the ProCore 20G FNB showed better histological parameters; although there was no difference in the diagnostic performance between the two needles, these findings may improve pathologist performance.Colégio Brasileiro de Cirurgia Digestiva2020-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-67202020000400305ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo) v.33 n.4 2020reponame:ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)instname:Colégio Brasileiro de Cirurgia Digestiva (CBCD)instacron:CBCD10.1590/0102-672020200004e1554info:eu-repo/semantics/openAccessARDENGH,José CelsoBRUNALDI,Vitor OttoboniBRUNALDI,Mariângela OttoboniGASPAR,Alberto FacuriLOPES-JÚNIOR,Jorge ResendeSANKARANKUTTY,Ajith KumarKEMP,RafaelSANTOS,José Sebastião doseng2021-01-21T00:00:00Zoai:scielo:S0102-67202020000400305Revistahttp://abarriguda.org.br/revista/index.php/revistaabarrigudaarepb/indexONGhttps://old.scielo.br/oai/scielo-oai.php||revistaabcd@gmail.com2317-63262317-6326opendoar:2021-01-21T00:00ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo) - Colégio Brasileiro de Cirurgia Digestiva (CBCD)false
dc.title.none.fl_str_mv IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
title IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
spellingShingle IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
ARDENGH,José Celso
Diagnosis
Endoscopic Ultrasound
Fine-Needle aspiration biopsy
Fine-needle biopsy
Pancreatic cancer
title_short IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
title_full IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
title_fullStr IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
title_full_unstemmed IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
title_sort IS THE NEW PROCORE 20G DOUBLE FORWARD-BEVEL NEEDLE CAPABLE TO OBTAIN BETTER HISTOLOGICAL SAMPLES BY ENDOSCOPIC ULTRASOUND FOR DIAGNOSING SOLID PANCREATIC LESIONS?
author ARDENGH,José Celso
author_facet ARDENGH,José Celso
BRUNALDI,Vitor Ottoboni
BRUNALDI,Mariângela Ottoboni
GASPAR,Alberto Facuri
LOPES-JÚNIOR,Jorge Resende
SANKARANKUTTY,Ajith Kumar
KEMP,Rafael
SANTOS,José Sebastião dos
author_role author
author2 BRUNALDI,Vitor Ottoboni
BRUNALDI,Mariângela Ottoboni
GASPAR,Alberto Facuri
LOPES-JÚNIOR,Jorge Resende
SANKARANKUTTY,Ajith Kumar
KEMP,Rafael
SANTOS,José Sebastião dos
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv ARDENGH,José Celso
BRUNALDI,Vitor Ottoboni
BRUNALDI,Mariângela Ottoboni
GASPAR,Alberto Facuri
LOPES-JÚNIOR,Jorge Resende
SANKARANKUTTY,Ajith Kumar
KEMP,Rafael
SANTOS,José Sebastião dos
dc.subject.por.fl_str_mv Diagnosis
Endoscopic Ultrasound
Fine-Needle aspiration biopsy
Fine-needle biopsy
Pancreatic cancer
topic Diagnosis
Endoscopic Ultrasound
Fine-Needle aspiration biopsy
Fine-needle biopsy
Pancreatic cancer
description ABSTRACT Background: It is important to obtain representative histological samples of solid biliopancreatic lesions without a clear indication for resection. The role of new needles in such task is yet to be determined. Aim: To compare performance assessment between 20G double fine needle biopsy (FNB) and conventional 22G fine needle aspiration (FNA) needles for endoscopic ultrasound (EUS)-guided biopsy. Methods: This prospective study examined 20 patients who underwent the random puncture of solid pancreatic lesions with both needles and the analysis of tissue samples by a single pathologist. Results: The ProCore 20G FNB needle provided more adequate tissue samples (16 vs. 9, p=0.039) with better cellularity quantitative scores (11 vs. 5, p=0.002) and larger diameter of the histological sample (1.51±1.3 mm vs. 0.94±0.55 mm, p=0.032) than the 22G needle. The technical success, puncture difficulty, and sample bleeding were similar between groups. The sensitivity, specificity, and diagnostic accuracy were 88.9%, 100%, and 90% and 77.8%, 100%, and 78.9% for the 20G and 22G needles, respectively. Conclusions: The samples obtained with the ProCore 20G FNB showed better histological parameters; although there was no difference in the diagnostic performance between the two needles, these findings may improve pathologist performance.
publishDate 2020
dc.date.none.fl_str_mv 2020-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-67202020000400305
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-67202020000400305
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0102-672020200004e1554
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Colégio Brasileiro de Cirurgia Digestiva
publisher.none.fl_str_mv Colégio Brasileiro de Cirurgia Digestiva
dc.source.none.fl_str_mv ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo) v.33 n.4 2020
reponame:ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
instname:Colégio Brasileiro de Cirurgia Digestiva (CBCD)
instacron:CBCD
instname_str Colégio Brasileiro de Cirurgia Digestiva (CBCD)
instacron_str CBCD
institution CBCD
reponame_str ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
collection ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
repository.name.fl_str_mv ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo) - Colégio Brasileiro de Cirurgia Digestiva (CBCD)
repository.mail.fl_str_mv ||revistaabcd@gmail.com
_version_ 1754208959127879680