Gonioscopy-assisted transluminal trabeculotomy (GATT) outcomes in eyes with open-angle glaucoma resistant to maximum treatment

Detalhes bibliográficos
Autor(a) principal: Faria,Bruno M. de
Data de Publicação: 2021
Outros Autores: Daga,Fábio B., Rebouças-Santos,Vespasiano, Araújo,Rafael B. de, Matos Neto,Carlos, Jacobina,Jéssica S., Faria,Marco A. R. de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000600587
Resumo: ABSTRACT Purpose: To report the initial 2 years’ learning curve on gonioscopy-assisted transluminal trabeculotomy performed using the thermally blunted suture technique and review the factors that could potentially affect the outcome. Methods: This retrospective study evaluated 100 eyes from 89 participants with glaucoma resistant to maximum clinical treatment, which was defined as having an intraocular pressure >21 mmHg in addition to three or four different hypotensive drugs. Intraocular pressure values at baseline, 1 week, and at 1, 2, 3, 6, 12, and 24 months of follow-up and details regarding the need of antiglaucoma medication and further glaucoma surgery were recorded. Eyes that required further surgical intervention for intraocular pressure control were considered as failure. Results: A total of 51 eyes were subjected to isolated gonioscopy-assisted transluminal trabeculotomy, and 49 eyes were subjected to gonioscopy-assisted transluminal trabeculotomy + cataract extraction at the same surgical time. A statistically significant difference was observed between overall mean follow-up intraocular pressure and mean preoperative intraocular pressure (p<0.001) in all follow-up visits. When the extent of treatment was evaluated, patients with an extension of 360° did not exhibit statistically significantly lower mean intraocular pressure than those with other extensions. Hyphema was the only complication presented in 50 eyes (50%), but all had spontaneous resolution within 4 weeks. A total of 26 eyes (26%) required additional conventional trabeculectomy due to uncontrolled intraocular pressure, especially those who previously underwent vitreoretinal surgery. Conclusions: Gonioscopy-assisted transluminal trabeculotomy, besides being an apparently safe procedure, results in satisfactory success rates even during the surgeon’s initial learning curve. The technique was effective in decreasing intraocular pressure and medication burden.
id CBO-2_18b8f15340444ef95c779ab790aa4d2b
oai_identifier_str oai:scielo:S0004-27492021000600587
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Gonioscopy-assisted transluminal trabeculotomy (GATT) outcomes in eyes with open-angle glaucoma resistant to maximum treatmentTrabeculectomy/methodsGlaucoma, open-angle/surgeryGonioscopy/methodsTreatment outcomeABSTRACT Purpose: To report the initial 2 years’ learning curve on gonioscopy-assisted transluminal trabeculotomy performed using the thermally blunted suture technique and review the factors that could potentially affect the outcome. Methods: This retrospective study evaluated 100 eyes from 89 participants with glaucoma resistant to maximum clinical treatment, which was defined as having an intraocular pressure >21 mmHg in addition to three or four different hypotensive drugs. Intraocular pressure values at baseline, 1 week, and at 1, 2, 3, 6, 12, and 24 months of follow-up and details regarding the need of antiglaucoma medication and further glaucoma surgery were recorded. Eyes that required further surgical intervention for intraocular pressure control were considered as failure. Results: A total of 51 eyes were subjected to isolated gonioscopy-assisted transluminal trabeculotomy, and 49 eyes were subjected to gonioscopy-assisted transluminal trabeculotomy + cataract extraction at the same surgical time. A statistically significant difference was observed between overall mean follow-up intraocular pressure and mean preoperative intraocular pressure (p<0.001) in all follow-up visits. When the extent of treatment was evaluated, patients with an extension of 360° did not exhibit statistically significantly lower mean intraocular pressure than those with other extensions. Hyphema was the only complication presented in 50 eyes (50%), but all had spontaneous resolution within 4 weeks. A total of 26 eyes (26%) required additional conventional trabeculectomy due to uncontrolled intraocular pressure, especially those who previously underwent vitreoretinal surgery. Conclusions: Gonioscopy-assisted transluminal trabeculotomy, besides being an apparently safe procedure, results in satisfactory success rates even during the surgeon’s initial learning curve. The technique was effective in decreasing intraocular pressure and medication burden.Conselho Brasileiro de Oftalmologia2021-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000600587Arquivos Brasileiros de Oftalmologia v.84 n.6 2021reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20210083info:eu-repo/semantics/openAccessFaria,Bruno M. deDaga,Fábio B.Rebouças-Santos,VespasianoAraújo,Rafael B. deMatos Neto,CarlosJacobina,Jéssica S.Faria,Marco A. R. deeng2021-11-18T00:00:00Zoai:scielo:S0004-27492021000600587Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2021-11-18T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Gonioscopy-assisted transluminal trabeculotomy (GATT) outcomes in eyes with open-angle glaucoma resistant to maximum treatment
title Gonioscopy-assisted transluminal trabeculotomy (GATT) outcomes in eyes with open-angle glaucoma resistant to maximum treatment
spellingShingle Gonioscopy-assisted transluminal trabeculotomy (GATT) outcomes in eyes with open-angle glaucoma resistant to maximum treatment
Faria,Bruno M. de
Trabeculectomy/methods
Glaucoma, open-angle/surgery
Gonioscopy/methods
Treatment outcome
title_short Gonioscopy-assisted transluminal trabeculotomy (GATT) outcomes in eyes with open-angle glaucoma resistant to maximum treatment
title_full Gonioscopy-assisted transluminal trabeculotomy (GATT) outcomes in eyes with open-angle glaucoma resistant to maximum treatment
title_fullStr Gonioscopy-assisted transluminal trabeculotomy (GATT) outcomes in eyes with open-angle glaucoma resistant to maximum treatment
title_full_unstemmed Gonioscopy-assisted transluminal trabeculotomy (GATT) outcomes in eyes with open-angle glaucoma resistant to maximum treatment
title_sort Gonioscopy-assisted transluminal trabeculotomy (GATT) outcomes in eyes with open-angle glaucoma resistant to maximum treatment
author Faria,Bruno M. de
author_facet Faria,Bruno M. de
Daga,Fábio B.
Rebouças-Santos,Vespasiano
Araújo,Rafael B. de
Matos Neto,Carlos
Jacobina,Jéssica S.
Faria,Marco A. R. de
author_role author
author2 Daga,Fábio B.
Rebouças-Santos,Vespasiano
Araújo,Rafael B. de
Matos Neto,Carlos
Jacobina,Jéssica S.
Faria,Marco A. R. de
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Faria,Bruno M. de
Daga,Fábio B.
Rebouças-Santos,Vespasiano
Araújo,Rafael B. de
Matos Neto,Carlos
Jacobina,Jéssica S.
Faria,Marco A. R. de
dc.subject.por.fl_str_mv Trabeculectomy/methods
Glaucoma, open-angle/surgery
Gonioscopy/methods
Treatment outcome
topic Trabeculectomy/methods
Glaucoma, open-angle/surgery
Gonioscopy/methods
Treatment outcome
description ABSTRACT Purpose: To report the initial 2 years’ learning curve on gonioscopy-assisted transluminal trabeculotomy performed using the thermally blunted suture technique and review the factors that could potentially affect the outcome. Methods: This retrospective study evaluated 100 eyes from 89 participants with glaucoma resistant to maximum clinical treatment, which was defined as having an intraocular pressure >21 mmHg in addition to three or four different hypotensive drugs. Intraocular pressure values at baseline, 1 week, and at 1, 2, 3, 6, 12, and 24 months of follow-up and details regarding the need of antiglaucoma medication and further glaucoma surgery were recorded. Eyes that required further surgical intervention for intraocular pressure control were considered as failure. Results: A total of 51 eyes were subjected to isolated gonioscopy-assisted transluminal trabeculotomy, and 49 eyes were subjected to gonioscopy-assisted transluminal trabeculotomy + cataract extraction at the same surgical time. A statistically significant difference was observed between overall mean follow-up intraocular pressure and mean preoperative intraocular pressure (p<0.001) in all follow-up visits. When the extent of treatment was evaluated, patients with an extension of 360° did not exhibit statistically significantly lower mean intraocular pressure than those with other extensions. Hyphema was the only complication presented in 50 eyes (50%), but all had spontaneous resolution within 4 weeks. A total of 26 eyes (26%) required additional conventional trabeculectomy due to uncontrolled intraocular pressure, especially those who previously underwent vitreoretinal surgery. Conclusions: Gonioscopy-assisted transluminal trabeculotomy, besides being an apparently safe procedure, results in satisfactory success rates even during the surgeon’s initial learning curve. The technique was effective in decreasing intraocular pressure and medication burden.
publishDate 2021
dc.date.none.fl_str_mv 2021-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000600587
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492021000600587
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20210083
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.84 n.6 2021
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209031394689024