Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes

Detalhes bibliográficos
Autor(a) principal: Henriquez,Maria A.
Data de Publicação: 2022
Outros Autores: Mosquera,Samuel-Arba, Camargo,Jorge, Izquierdo Jr.,Luis
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492022000500443
Resumo: ABSTRACT Purpose: To evaluate the vision quality by measuring the objective light scatter index and objective optical quality parameters (Strehl Ratio and Modulation Transfer Function) in patients with emmetropia and ametropia. Methods: This prospective, cross-sectional study included 408 eyes. The ametropic group comprised of eyes with best-corrected visual acuity of 0.0 logMAR or better and present at least a refractive error of ≥0.25 D. Patients underwent slit lamp examination, visual acuity, refraction, and vision quality using the HD Analyzer. Results: The mean objective light scatter indices were 0.62 ± 0.63, 0.77 ± 0.70, 0.74 ± 0.30, 0.93 ± 0.55, and 0.85 ± 0.61, and mean Strehl Ratio and Modulation Transfer Function scores were 38.17 ± 10.4, 37.37 ± 10.06, 29.84 ± 9.71, 33.2 ± 12.11, and 33.13 ± 10.09 in emmetropes, myopia, hyperopia, spherical equivalent of ≥0, and spherical equivalent of <0, respectively. Differences in all variables were significant between emmetropic and corrected hyperopic and between spherical equivalent of ≥0, and spherical equivalent of <0 eyes (p<0.05). Conclusion: In spectacle-corrected conditions (with trial frames), emmetropic and simple myopic eyes had significantly better vision quality compared to hyperopic and astigmatic eyes. The clinical significance of these results should be investigated in further studies.
id CBO-2_237435d42bfefc47aff33f821ce0eb7f
oai_identifier_str oai:scielo:S0004-27492022000500443
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyesRefractive errorEmmetropiaOptical deviceDiagnostic technique, ophthalmological/instrumentationRefraction, ocularVisual acuityABSTRACT Purpose: To evaluate the vision quality by measuring the objective light scatter index and objective optical quality parameters (Strehl Ratio and Modulation Transfer Function) in patients with emmetropia and ametropia. Methods: This prospective, cross-sectional study included 408 eyes. The ametropic group comprised of eyes with best-corrected visual acuity of 0.0 logMAR or better and present at least a refractive error of ≥0.25 D. Patients underwent slit lamp examination, visual acuity, refraction, and vision quality using the HD Analyzer. Results: The mean objective light scatter indices were 0.62 ± 0.63, 0.77 ± 0.70, 0.74 ± 0.30, 0.93 ± 0.55, and 0.85 ± 0.61, and mean Strehl Ratio and Modulation Transfer Function scores were 38.17 ± 10.4, 37.37 ± 10.06, 29.84 ± 9.71, 33.2 ± 12.11, and 33.13 ± 10.09 in emmetropes, myopia, hyperopia, spherical equivalent of ≥0, and spherical equivalent of <0, respectively. Differences in all variables were significant between emmetropic and corrected hyperopic and between spherical equivalent of ≥0, and spherical equivalent of <0 eyes (p<0.05). Conclusion: In spectacle-corrected conditions (with trial frames), emmetropic and simple myopic eyes had significantly better vision quality compared to hyperopic and astigmatic eyes. The clinical significance of these results should be investigated in further studies.Conselho Brasileiro de Oftalmologia2022-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492022000500443Arquivos Brasileiros de Oftalmologia v.85 n.5 2022reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20220050info:eu-repo/semantics/openAccessHenriquez,Maria A.Mosquera,Samuel-ArbaCamargo,JorgeIzquierdo Jr.,Luiseng2022-10-07T00:00:00Zoai:scielo:S0004-27492022000500443Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2022-10-07T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes
title Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes
spellingShingle Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes
Henriquez,Maria A.
Refractive error
Emmetropia
Optical device
Diagnostic technique, ophthalmological/instrumentation
Refraction, ocular
Visual acuity
title_short Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes
title_full Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes
title_fullStr Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes
title_full_unstemmed Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes
title_sort Comparing the vision quality using double-pass technique in eyes with corrected refractive errors and emmetropic eyes
author Henriquez,Maria A.
author_facet Henriquez,Maria A.
Mosquera,Samuel-Arba
Camargo,Jorge
Izquierdo Jr.,Luis
author_role author
author2 Mosquera,Samuel-Arba
Camargo,Jorge
Izquierdo Jr.,Luis
author2_role author
author
author
dc.contributor.author.fl_str_mv Henriquez,Maria A.
Mosquera,Samuel-Arba
Camargo,Jorge
Izquierdo Jr.,Luis
dc.subject.por.fl_str_mv Refractive error
Emmetropia
Optical device
Diagnostic technique, ophthalmological/instrumentation
Refraction, ocular
Visual acuity
topic Refractive error
Emmetropia
Optical device
Diagnostic technique, ophthalmological/instrumentation
Refraction, ocular
Visual acuity
description ABSTRACT Purpose: To evaluate the vision quality by measuring the objective light scatter index and objective optical quality parameters (Strehl Ratio and Modulation Transfer Function) in patients with emmetropia and ametropia. Methods: This prospective, cross-sectional study included 408 eyes. The ametropic group comprised of eyes with best-corrected visual acuity of 0.0 logMAR or better and present at least a refractive error of ≥0.25 D. Patients underwent slit lamp examination, visual acuity, refraction, and vision quality using the HD Analyzer. Results: The mean objective light scatter indices were 0.62 ± 0.63, 0.77 ± 0.70, 0.74 ± 0.30, 0.93 ± 0.55, and 0.85 ± 0.61, and mean Strehl Ratio and Modulation Transfer Function scores were 38.17 ± 10.4, 37.37 ± 10.06, 29.84 ± 9.71, 33.2 ± 12.11, and 33.13 ± 10.09 in emmetropes, myopia, hyperopia, spherical equivalent of ≥0, and spherical equivalent of <0, respectively. Differences in all variables were significant between emmetropic and corrected hyperopic and between spherical equivalent of ≥0, and spherical equivalent of <0 eyes (p<0.05). Conclusion: In spectacle-corrected conditions (with trial frames), emmetropic and simple myopic eyes had significantly better vision quality compared to hyperopic and astigmatic eyes. The clinical significance of these results should be investigated in further studies.
publishDate 2022
dc.date.none.fl_str_mv 2022-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492022000500443
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492022000500443
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20220050
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.85 n.5 2022
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209031869693952