Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)

Detalhes bibliográficos
Autor(a) principal: Botsford,Benjamin
Data de Publicação: 2016
Outros Autores: Vedana,Gustavo, Cope,Leslie, Yiu,Samuel C., Jun,Albert S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000500299
Resumo: ABSTRACT Purpose: To compare the effect of 20% sulfur hexafluoride (SF6) with that of air on graft detachment rates for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK). Methods: Forty-two eyes of patients who underwent DMEK by a single surgeon (A.S.J.) at Wilmer Eye Institute between January 2012 and 2014 were identified; 21 received air for intraocular tamponade and the next consecutive 21 received SF6. The main outcome measure was the graft detachment rate; univariate and multivariate analyses were performed. Results: The graft detachment rate was 67% in the air group and 19% in the SF6 group (p<0.05). No complete graft detachments occurred, and all partial detachments underwent intervention with injection of intraocular air. The percentages of eyes with 20/25 or better vision were not different between the groups (67% vs. 71%). Univariate analysis showed significantly higher detachment rates with air tamponade (OR, 8.50; p<0.005) and larger donor graft size (OR, 14.96; p<0.05). Multivariate analysis with gas but not graft size included showed that gas was an independent statistically significant predictor of outcome (OR, 6.65; p<0.05). When graft size was included as a covariate, gas was no longer a statistically significant predictor of detachment but maintained OR of 7.81 (p=0.063) similar to the results of univariate and multivariate analyses without graft size. Conclusion: In comparison with air, graft detachment rates for intraocular tamponade in DMEK were significantly reduced by 20% SF6.
id CBO-2_271f1a55655ab05f881e9a4563a50651
oai_identifier_str oai:scielo:S0004-27492016000500299
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)Descemet membraneDescemet stripping endothelial keratoplasty/instrumentationSulfur hexafluoride/administration &amp; dosageEndotamponadeVisual acuityABSTRACT Purpose: To compare the effect of 20% sulfur hexafluoride (SF6) with that of air on graft detachment rates for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK). Methods: Forty-two eyes of patients who underwent DMEK by a single surgeon (A.S.J.) at Wilmer Eye Institute between January 2012 and 2014 were identified; 21 received air for intraocular tamponade and the next consecutive 21 received SF6. The main outcome measure was the graft detachment rate; univariate and multivariate analyses were performed. Results: The graft detachment rate was 67% in the air group and 19% in the SF6 group (p<0.05). No complete graft detachments occurred, and all partial detachments underwent intervention with injection of intraocular air. The percentages of eyes with 20/25 or better vision were not different between the groups (67% vs. 71%). Univariate analysis showed significantly higher detachment rates with air tamponade (OR, 8.50; p<0.005) and larger donor graft size (OR, 14.96; p<0.05). Multivariate analysis with gas but not graft size included showed that gas was an independent statistically significant predictor of outcome (OR, 6.65; p<0.05). When graft size was included as a covariate, gas was no longer a statistically significant predictor of detachment but maintained OR of 7.81 (p=0.063) similar to the results of univariate and multivariate analyses without graft size. Conclusion: In comparison with air, graft detachment rates for intraocular tamponade in DMEK were significantly reduced by 20% SF6.Conselho Brasileiro de Oftalmologia2016-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000500299Arquivos Brasileiros de Oftalmologia v.79 n.5 2016reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20160086info:eu-repo/semantics/openAccessBotsford,BenjaminVedana,GustavoCope,LeslieYiu,Samuel C.Jun,Albert S.eng2016-11-30T00:00:00Zoai:scielo:S0004-27492016000500299Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2016-11-30T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)
title Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)
spellingShingle Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)
Botsford,Benjamin
Descemet membrane
Descemet stripping endothelial keratoplasty/instrumentation
Sulfur hexafluoride/administration &amp; dosage
Endotamponade
Visual acuity
title_short Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)
title_full Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)
title_fullStr Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)
title_full_unstemmed Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)
title_sort Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)
author Botsford,Benjamin
author_facet Botsford,Benjamin
Vedana,Gustavo
Cope,Leslie
Yiu,Samuel C.
Jun,Albert S.
author_role author
author2 Vedana,Gustavo
Cope,Leslie
Yiu,Samuel C.
Jun,Albert S.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Botsford,Benjamin
Vedana,Gustavo
Cope,Leslie
Yiu,Samuel C.
Jun,Albert S.
dc.subject.por.fl_str_mv Descemet membrane
Descemet stripping endothelial keratoplasty/instrumentation
Sulfur hexafluoride/administration &amp; dosage
Endotamponade
Visual acuity
topic Descemet membrane
Descemet stripping endothelial keratoplasty/instrumentation
Sulfur hexafluoride/administration &amp; dosage
Endotamponade
Visual acuity
description ABSTRACT Purpose: To compare the effect of 20% sulfur hexafluoride (SF6) with that of air on graft detachment rates for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK). Methods: Forty-two eyes of patients who underwent DMEK by a single surgeon (A.S.J.) at Wilmer Eye Institute between January 2012 and 2014 were identified; 21 received air for intraocular tamponade and the next consecutive 21 received SF6. The main outcome measure was the graft detachment rate; univariate and multivariate analyses were performed. Results: The graft detachment rate was 67% in the air group and 19% in the SF6 group (p<0.05). No complete graft detachments occurred, and all partial detachments underwent intervention with injection of intraocular air. The percentages of eyes with 20/25 or better vision were not different between the groups (67% vs. 71%). Univariate analysis showed significantly higher detachment rates with air tamponade (OR, 8.50; p<0.005) and larger donor graft size (OR, 14.96; p<0.05). Multivariate analysis with gas but not graft size included showed that gas was an independent statistically significant predictor of outcome (OR, 6.65; p<0.05). When graft size was included as a covariate, gas was no longer a statistically significant predictor of detachment but maintained OR of 7.81 (p=0.063) similar to the results of univariate and multivariate analyses without graft size. Conclusion: In comparison with air, graft detachment rates for intraocular tamponade in DMEK were significantly reduced by 20% SF6.
publishDate 2016
dc.date.none.fl_str_mv 2016-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000500299
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000500299
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20160086
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.79 n.5 2016
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209029053218816