Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000500299 |
Resumo: | ABSTRACT Purpose: To compare the effect of 20% sulfur hexafluoride (SF6) with that of air on graft detachment rates for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK). Methods: Forty-two eyes of patients who underwent DMEK by a single surgeon (A.S.J.) at Wilmer Eye Institute between January 2012 and 2014 were identified; 21 received air for intraocular tamponade and the next consecutive 21 received SF6. The main outcome measure was the graft detachment rate; univariate and multivariate analyses were performed. Results: The graft detachment rate was 67% in the air group and 19% in the SF6 group (p<0.05). No complete graft detachments occurred, and all partial detachments underwent intervention with injection of intraocular air. The percentages of eyes with 20/25 or better vision were not different between the groups (67% vs. 71%). Univariate analysis showed significantly higher detachment rates with air tamponade (OR, 8.50; p<0.005) and larger donor graft size (OR, 14.96; p<0.05). Multivariate analysis with gas but not graft size included showed that gas was an independent statistically significant predictor of outcome (OR, 6.65; p<0.05). When graft size was included as a covariate, gas was no longer a statistically significant predictor of detachment but maintained OR of 7.81 (p=0.063) similar to the results of univariate and multivariate analyses without graft size. Conclusion: In comparison with air, graft detachment rates for intraocular tamponade in DMEK were significantly reduced by 20% SF6. |
id |
CBO-2_271f1a55655ab05f881e9a4563a50651 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492016000500299 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK)Descemet membraneDescemet stripping endothelial keratoplasty/instrumentationSulfur hexafluoride/administration & dosageEndotamponadeVisual acuityABSTRACT Purpose: To compare the effect of 20% sulfur hexafluoride (SF6) with that of air on graft detachment rates for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK). Methods: Forty-two eyes of patients who underwent DMEK by a single surgeon (A.S.J.) at Wilmer Eye Institute between January 2012 and 2014 were identified; 21 received air for intraocular tamponade and the next consecutive 21 received SF6. The main outcome measure was the graft detachment rate; univariate and multivariate analyses were performed. Results: The graft detachment rate was 67% in the air group and 19% in the SF6 group (p<0.05). No complete graft detachments occurred, and all partial detachments underwent intervention with injection of intraocular air. The percentages of eyes with 20/25 or better vision were not different between the groups (67% vs. 71%). Univariate analysis showed significantly higher detachment rates with air tamponade (OR, 8.50; p<0.005) and larger donor graft size (OR, 14.96; p<0.05). Multivariate analysis with gas but not graft size included showed that gas was an independent statistically significant predictor of outcome (OR, 6.65; p<0.05). When graft size was included as a covariate, gas was no longer a statistically significant predictor of detachment but maintained OR of 7.81 (p=0.063) similar to the results of univariate and multivariate analyses without graft size. Conclusion: In comparison with air, graft detachment rates for intraocular tamponade in DMEK were significantly reduced by 20% SF6.Conselho Brasileiro de Oftalmologia2016-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000500299Arquivos Brasileiros de Oftalmologia v.79 n.5 2016reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20160086info:eu-repo/semantics/openAccessBotsford,BenjaminVedana,GustavoCope,LeslieYiu,Samuel C.Jun,Albert S.eng2016-11-30T00:00:00Zoai:scielo:S0004-27492016000500299Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2016-11-30T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK) |
title |
Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK) |
spellingShingle |
Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK) Botsford,Benjamin Descemet membrane Descemet stripping endothelial keratoplasty/instrumentation Sulfur hexafluoride/administration & dosage Endotamponade Visual acuity |
title_short |
Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK) |
title_full |
Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK) |
title_fullStr |
Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK) |
title_full_unstemmed |
Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK) |
title_sort |
Comparison of 20% sulfur hexafluoride with air for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK) |
author |
Botsford,Benjamin |
author_facet |
Botsford,Benjamin Vedana,Gustavo Cope,Leslie Yiu,Samuel C. Jun,Albert S. |
author_role |
author |
author2 |
Vedana,Gustavo Cope,Leslie Yiu,Samuel C. Jun,Albert S. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Botsford,Benjamin Vedana,Gustavo Cope,Leslie Yiu,Samuel C. Jun,Albert S. |
dc.subject.por.fl_str_mv |
Descemet membrane Descemet stripping endothelial keratoplasty/instrumentation Sulfur hexafluoride/administration & dosage Endotamponade Visual acuity |
topic |
Descemet membrane Descemet stripping endothelial keratoplasty/instrumentation Sulfur hexafluoride/administration & dosage Endotamponade Visual acuity |
description |
ABSTRACT Purpose: To compare the effect of 20% sulfur hexafluoride (SF6) with that of air on graft detachment rates for intraocular tamponade in Descemet membrane endothelial keratoplasty (DMEK). Methods: Forty-two eyes of patients who underwent DMEK by a single surgeon (A.S.J.) at Wilmer Eye Institute between January 2012 and 2014 were identified; 21 received air for intraocular tamponade and the next consecutive 21 received SF6. The main outcome measure was the graft detachment rate; univariate and multivariate analyses were performed. Results: The graft detachment rate was 67% in the air group and 19% in the SF6 group (p<0.05). No complete graft detachments occurred, and all partial detachments underwent intervention with injection of intraocular air. The percentages of eyes with 20/25 or better vision were not different between the groups (67% vs. 71%). Univariate analysis showed significantly higher detachment rates with air tamponade (OR, 8.50; p<0.005) and larger donor graft size (OR, 14.96; p<0.05). Multivariate analysis with gas but not graft size included showed that gas was an independent statistically significant predictor of outcome (OR, 6.65; p<0.05). When graft size was included as a covariate, gas was no longer a statistically significant predictor of detachment but maintained OR of 7.81 (p=0.063) similar to the results of univariate and multivariate analyses without graft size. Conclusion: In comparison with air, graft detachment rates for intraocular tamponade in DMEK were significantly reduced by 20% SF6. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000500299 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000500299 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0004-2749.20160086 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.79 n.5 2016 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209029053218816 |