Intraocular pressure fluctuation in healthy and glaucomatous eyes: a comparative analysis between diurnal curves in supine and sitting positions and the water drinking test

Detalhes bibliográficos
Autor(a) principal: Caiado,Rafael Ramos
Data de Publicação: 2014
Outros Autores: Badaró,Emmerson, Kasahara,Niro
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000500278
Resumo: Purpose: To compare intraocular pressure (IOP) using the simplified daily tensional curve (SDTC) between supine and sitting positions in terms of peak levels and amount of fluctuation in both, glaucomatous and healthy subjects. The secondary endpoint was the comparison of these measures with those derived from the water drinking test (WDT). Methods: Thirty patients with primary open-angle glaucoma (POAG) that were undergoing medical therapy and 30 healthy subjects were enrolled in this study. Each patient underwent a diurnal curve between 8 am and 4 pm. After lying down for 5 minutes, the IOP was measured with the Perkins tonometer. Patients were instructed to sit in the upright position for 5 minutes and the tonometry was repeated. At 4:15 pm, the WDT test was performed. Fluctuation was defined as the difference between the highest and the lowest IOP readings (range). The Student's t test was used to assess differences and a P value <0.05 was considered to be statistically significant. Results: The diurnal curve in the supine position demonstrated higher IOP average values (on average 3-4 mmHg higher) compared to the sitting position (p<0.0001) for both groups. IOP peaks were higher in the supine position; however, the IOP range was essentially the same between the three methods. Treated glaucomatous patients had higher IOP levels in all measurements, but the fluctuation for all tests performed appeared to be similar to that of healthy patients. Conclusion: The data suggested that WDT can be used to estimate the diurnal IOP peak and fluctuation observed in the SDTC of the supine position for treated glaucomatous patients. Further studies can compare the possible correlation between the WDT results and those obtained from nocturnal supine measurements.
id CBO-2_334b2116652ae332457f1dba9b1e9515
oai_identifier_str oai:scielo:S0004-27492014000500278
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Intraocular pressure fluctuation in healthy and glaucomatous eyes: a comparative analysis between diurnal curves in supine and sitting positions and the water drinking testGlaucoma, open-angle/physiopathologyIntraocular pressure/physiologyCircadian rhythm Purpose: To compare intraocular pressure (IOP) using the simplified daily tensional curve (SDTC) between supine and sitting positions in terms of peak levels and amount of fluctuation in both, glaucomatous and healthy subjects. The secondary endpoint was the comparison of these measures with those derived from the water drinking test (WDT). Methods: Thirty patients with primary open-angle glaucoma (POAG) that were undergoing medical therapy and 30 healthy subjects were enrolled in this study. Each patient underwent a diurnal curve between 8 am and 4 pm. After lying down for 5 minutes, the IOP was measured with the Perkins tonometer. Patients were instructed to sit in the upright position for 5 minutes and the tonometry was repeated. At 4:15 pm, the WDT test was performed. Fluctuation was defined as the difference between the highest and the lowest IOP readings (range). The Student's t test was used to assess differences and a P value <0.05 was considered to be statistically significant. Results: The diurnal curve in the supine position demonstrated higher IOP average values (on average 3-4 mmHg higher) compared to the sitting position (p<0.0001) for both groups. IOP peaks were higher in the supine position; however, the IOP range was essentially the same between the three methods. Treated glaucomatous patients had higher IOP levels in all measurements, but the fluctuation for all tests performed appeared to be similar to that of healthy patients. Conclusion: The data suggested that WDT can be used to estimate the diurnal IOP peak and fluctuation observed in the SDTC of the supine position for treated glaucomatous patients. Further studies can compare the possible correlation between the WDT results and those obtained from nocturnal supine measurements. Conselho Brasileiro de Oftalmologia2014-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000500278Arquivos Brasileiros de Oftalmologia v.77 n.5 2014reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20140073info:eu-repo/semantics/openAccessCaiado,Rafael RamosBadaró,EmmersonKasahara,Niroeng2015-04-10T00:00:00Zoai:scielo:S0004-27492014000500278Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2015-04-10T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Intraocular pressure fluctuation in healthy and glaucomatous eyes: a comparative analysis between diurnal curves in supine and sitting positions and the water drinking test
title Intraocular pressure fluctuation in healthy and glaucomatous eyes: a comparative analysis between diurnal curves in supine and sitting positions and the water drinking test
spellingShingle Intraocular pressure fluctuation in healthy and glaucomatous eyes: a comparative analysis between diurnal curves in supine and sitting positions and the water drinking test
Caiado,Rafael Ramos
Glaucoma, open-angle/physiopathology
Intraocular pressure/physiology
Circadian rhythm
title_short Intraocular pressure fluctuation in healthy and glaucomatous eyes: a comparative analysis between diurnal curves in supine and sitting positions and the water drinking test
title_full Intraocular pressure fluctuation in healthy and glaucomatous eyes: a comparative analysis between diurnal curves in supine and sitting positions and the water drinking test
title_fullStr Intraocular pressure fluctuation in healthy and glaucomatous eyes: a comparative analysis between diurnal curves in supine and sitting positions and the water drinking test
title_full_unstemmed Intraocular pressure fluctuation in healthy and glaucomatous eyes: a comparative analysis between diurnal curves in supine and sitting positions and the water drinking test
title_sort Intraocular pressure fluctuation in healthy and glaucomatous eyes: a comparative analysis between diurnal curves in supine and sitting positions and the water drinking test
author Caiado,Rafael Ramos
author_facet Caiado,Rafael Ramos
Badaró,Emmerson
Kasahara,Niro
author_role author
author2 Badaró,Emmerson
Kasahara,Niro
author2_role author
author
dc.contributor.author.fl_str_mv Caiado,Rafael Ramos
Badaró,Emmerson
Kasahara,Niro
dc.subject.por.fl_str_mv Glaucoma, open-angle/physiopathology
Intraocular pressure/physiology
Circadian rhythm
topic Glaucoma, open-angle/physiopathology
Intraocular pressure/physiology
Circadian rhythm
description Purpose: To compare intraocular pressure (IOP) using the simplified daily tensional curve (SDTC) between supine and sitting positions in terms of peak levels and amount of fluctuation in both, glaucomatous and healthy subjects. The secondary endpoint was the comparison of these measures with those derived from the water drinking test (WDT). Methods: Thirty patients with primary open-angle glaucoma (POAG) that were undergoing medical therapy and 30 healthy subjects were enrolled in this study. Each patient underwent a diurnal curve between 8 am and 4 pm. After lying down for 5 minutes, the IOP was measured with the Perkins tonometer. Patients were instructed to sit in the upright position for 5 minutes and the tonometry was repeated. At 4:15 pm, the WDT test was performed. Fluctuation was defined as the difference between the highest and the lowest IOP readings (range). The Student's t test was used to assess differences and a P value <0.05 was considered to be statistically significant. Results: The diurnal curve in the supine position demonstrated higher IOP average values (on average 3-4 mmHg higher) compared to the sitting position (p<0.0001) for both groups. IOP peaks were higher in the supine position; however, the IOP range was essentially the same between the three methods. Treated glaucomatous patients had higher IOP levels in all measurements, but the fluctuation for all tests performed appeared to be similar to that of healthy patients. Conclusion: The data suggested that WDT can be used to estimate the diurnal IOP peak and fluctuation observed in the SDTC of the supine position for treated glaucomatous patients. Further studies can compare the possible correlation between the WDT results and those obtained from nocturnal supine measurements.
publishDate 2014
dc.date.none.fl_str_mv 2014-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000500278
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000500278
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20140073
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.77 n.5 2014
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209028190240768