Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique

Detalhes bibliográficos
Autor(a) principal: Yavuzer,Kamil
Data de Publicação: 2019
Outros Autores: Evcimen,Yusuf
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000500389
Resumo: ABSTRACT Purpose: To evaluate the efficacy and safety of the modified Yamane technique with sutureless transconjunctival intrascleral intraocular lens fixation. Methods: Sutureless transconjunctival intrascleral haptic fixated intraocular lens implantation was performed in patients with aphakia and dislocated intraocular lenses. A clear corneal incision (2.8 mm) was made into the temporal quadrant and a three-piece intraocular lens was implanted into the anterior chamber. The haptics of the intraocular lens were externalized with a 27 G needle via transconjunctival scleral tunnels at the 6 and 12 o’clock positions. The transconjunctival scleral tunnels were prepared to conform to the haptic position and curvature. The site of the scleral tunnels was 2mm from the limbus with a length of 2 mm in the sclera and was aimed at the end of the posterior chamber. The tips of the haptics were cauterized to create a terminal knob. The haptics were pushed back and the knobs were implanted into the scleral tunnels. Results: The study cohort included 21 patients with unilateral aphakia and dislocated intraocular lenses. All patients were examined postoperatively and at postoperative day 1, day 7, month 1, and month 3. All examinations revealed formation of the anterior chamber and well-centralized intraocular lenses. No haptic-related complications of exposure, foreign body sensation, or discomfort were observed. Conclusion: Sutureless transconjunctival intrascleral haptic fixated intraocular lensimplantation is an effective, safe, and practical surgical alternative. This technique was superior to the Yamane method with regard to comfort and surgical duration. Further studies with longer follow-up evaluations are warranted to verify long-term complications.
id CBO-2_3a999c1b12b87c6f15a339a17380827e
oai_identifier_str oai:scielo:S0004-27492019000500389
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane techniqueAphakiaIntraocular lens implantationLens, intraocularSutureless surgical procedures/instrumentationOphthalmologic surgical procedures/methodsABSTRACT Purpose: To evaluate the efficacy and safety of the modified Yamane technique with sutureless transconjunctival intrascleral intraocular lens fixation. Methods: Sutureless transconjunctival intrascleral haptic fixated intraocular lens implantation was performed in patients with aphakia and dislocated intraocular lenses. A clear corneal incision (2.8 mm) was made into the temporal quadrant and a three-piece intraocular lens was implanted into the anterior chamber. The haptics of the intraocular lens were externalized with a 27 G needle via transconjunctival scleral tunnels at the 6 and 12 o’clock positions. The transconjunctival scleral tunnels were prepared to conform to the haptic position and curvature. The site of the scleral tunnels was 2mm from the limbus with a length of 2 mm in the sclera and was aimed at the end of the posterior chamber. The tips of the haptics were cauterized to create a terminal knob. The haptics were pushed back and the knobs were implanted into the scleral tunnels. Results: The study cohort included 21 patients with unilateral aphakia and dislocated intraocular lenses. All patients were examined postoperatively and at postoperative day 1, day 7, month 1, and month 3. All examinations revealed formation of the anterior chamber and well-centralized intraocular lenses. No haptic-related complications of exposure, foreign body sensation, or discomfort were observed. Conclusion: Sutureless transconjunctival intrascleral haptic fixated intraocular lensimplantation is an effective, safe, and practical surgical alternative. This technique was superior to the Yamane method with regard to comfort and surgical duration. Further studies with longer follow-up evaluations are warranted to verify long-term complications.Conselho Brasileiro de Oftalmologia2019-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000500389Arquivos Brasileiros de Oftalmologia v.82 n.5 2019reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20190072info:eu-repo/semantics/openAccessYavuzer,KamilEvcimen,Yusufeng2019-09-05T00:00:00Zoai:scielo:S0004-27492019000500389Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2019-09-05T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique
title Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique
spellingShingle Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique
Yavuzer,Kamil
Aphakia
Intraocular lens implantation
Lens, intraocular
Sutureless surgical procedures/instrumentation
Ophthalmologic surgical procedures/methods
title_short Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique
title_full Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique
title_fullStr Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique
title_full_unstemmed Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique
title_sort Sutureless transconjunctival intrascleral intraocular lens fixation: the modified Yamane technique
author Yavuzer,Kamil
author_facet Yavuzer,Kamil
Evcimen,Yusuf
author_role author
author2 Evcimen,Yusuf
author2_role author
dc.contributor.author.fl_str_mv Yavuzer,Kamil
Evcimen,Yusuf
dc.subject.por.fl_str_mv Aphakia
Intraocular lens implantation
Lens, intraocular
Sutureless surgical procedures/instrumentation
Ophthalmologic surgical procedures/methods
topic Aphakia
Intraocular lens implantation
Lens, intraocular
Sutureless surgical procedures/instrumentation
Ophthalmologic surgical procedures/methods
description ABSTRACT Purpose: To evaluate the efficacy and safety of the modified Yamane technique with sutureless transconjunctival intrascleral intraocular lens fixation. Methods: Sutureless transconjunctival intrascleral haptic fixated intraocular lens implantation was performed in patients with aphakia and dislocated intraocular lenses. A clear corneal incision (2.8 mm) was made into the temporal quadrant and a three-piece intraocular lens was implanted into the anterior chamber. The haptics of the intraocular lens were externalized with a 27 G needle via transconjunctival scleral tunnels at the 6 and 12 o’clock positions. The transconjunctival scleral tunnels were prepared to conform to the haptic position and curvature. The site of the scleral tunnels was 2mm from the limbus with a length of 2 mm in the sclera and was aimed at the end of the posterior chamber. The tips of the haptics were cauterized to create a terminal knob. The haptics were pushed back and the knobs were implanted into the scleral tunnels. Results: The study cohort included 21 patients with unilateral aphakia and dislocated intraocular lenses. All patients were examined postoperatively and at postoperative day 1, day 7, month 1, and month 3. All examinations revealed formation of the anterior chamber and well-centralized intraocular lenses. No haptic-related complications of exposure, foreign body sensation, or discomfort were observed. Conclusion: Sutureless transconjunctival intrascleral haptic fixated intraocular lensimplantation is an effective, safe, and practical surgical alternative. This technique was superior to the Yamane method with regard to comfort and surgical duration. Further studies with longer follow-up evaluations are warranted to verify long-term complications.
publishDate 2019
dc.date.none.fl_str_mv 2019-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000500389
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000500389
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20190072
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.82 n.5 2019
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209030383861760