Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000400209 |
Resumo: | ABSTRACT Purpose: To investigate the effects of the Valsalva maneuver (VM) on optic disc morphology, choroidal thickness, and anterior chamber parameters. Methods: This prospective observational study included 60 eyes of 60 healthy subjects. The anterior chamber parameters, including central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), pupil diameter (PD), axial length (AL), subfoveal and peripapillary choroidal thickness, optic disc parameters, and intraocular pressure (IOP), were measured at rest and during VM. Results: VM did not have any significant influence on AL, subfoveal and peripapillary choroidal thickness, optic disc area, rim area, cup area, cup-to-disc area ratio, vertical cup-to-disc ratio, rim volume, cup volume, and nerve head volume measurements (for all; p >0.05). IOP and PD significantly increased during VM (for both; p <0.001). VM significantly decreased CCT, ACD, ACA, and ACV values (for all; p <0.001). Moreover, the optic nerve cup volume decreased and the horizontal cup-to-disc ratio significantly increased during VM (for both; p <0.05). Conclusions: VM may cause transient changes in IOP, optic disc morphology, and anterior chamber parameters. |
id |
CBO-2_3cbe84b4b298b315aef3644853f95560 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492016000400209 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuverValsalva maneuverOptic disc/anatomy & histologyChoroid/anatomy & histologyIntraocular pressureAnterior chamberABSTRACT Purpose: To investigate the effects of the Valsalva maneuver (VM) on optic disc morphology, choroidal thickness, and anterior chamber parameters. Methods: This prospective observational study included 60 eyes of 60 healthy subjects. The anterior chamber parameters, including central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), pupil diameter (PD), axial length (AL), subfoveal and peripapillary choroidal thickness, optic disc parameters, and intraocular pressure (IOP), were measured at rest and during VM. Results: VM did not have any significant influence on AL, subfoveal and peripapillary choroidal thickness, optic disc area, rim area, cup area, cup-to-disc area ratio, vertical cup-to-disc ratio, rim volume, cup volume, and nerve head volume measurements (for all; p >0.05). IOP and PD significantly increased during VM (for both; p <0.001). VM significantly decreased CCT, ACD, ACA, and ACV values (for all; p <0.001). Moreover, the optic nerve cup volume decreased and the horizontal cup-to-disc ratio significantly increased during VM (for both; p <0.05). Conclusions: VM may cause transient changes in IOP, optic disc morphology, and anterior chamber parameters.Conselho Brasileiro de Oftalmologia2016-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000400209Arquivos Brasileiros de Oftalmologia v.79 n.4 2016reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20160061info:eu-repo/semantics/openAccessMete,AlperKimyon,SabitSaygılı,OğuzhanEvişen,AlperPamukcu,CanÇeri,SedaGüngör,Kıvançeng2016-09-05T00:00:00Zoai:scielo:S0004-27492016000400209Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2016-09-05T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver |
title |
Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver |
spellingShingle |
Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver Mete,Alper Valsalva maneuver Optic disc/anatomy & histology Choroid/anatomy & histology Intraocular pressure Anterior chamber |
title_short |
Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver |
title_full |
Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver |
title_fullStr |
Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver |
title_full_unstemmed |
Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver |
title_sort |
Dynamic changes in optic disc morphology, choroidal thickness, anterior chamber parameters, and intraocular pressure during Valsalva maneuver |
author |
Mete,Alper |
author_facet |
Mete,Alper Kimyon,Sabit Saygılı,Oğuzhan Evişen,Alper Pamukcu,Can Çeri,Seda Güngör,Kıvanç |
author_role |
author |
author2 |
Kimyon,Sabit Saygılı,Oğuzhan Evişen,Alper Pamukcu,Can Çeri,Seda Güngör,Kıvanç |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Mete,Alper Kimyon,Sabit Saygılı,Oğuzhan Evişen,Alper Pamukcu,Can Çeri,Seda Güngör,Kıvanç |
dc.subject.por.fl_str_mv |
Valsalva maneuver Optic disc/anatomy & histology Choroid/anatomy & histology Intraocular pressure Anterior chamber |
topic |
Valsalva maneuver Optic disc/anatomy & histology Choroid/anatomy & histology Intraocular pressure Anterior chamber |
description |
ABSTRACT Purpose: To investigate the effects of the Valsalva maneuver (VM) on optic disc morphology, choroidal thickness, and anterior chamber parameters. Methods: This prospective observational study included 60 eyes of 60 healthy subjects. The anterior chamber parameters, including central corneal thickness (CCT), anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), pupil diameter (PD), axial length (AL), subfoveal and peripapillary choroidal thickness, optic disc parameters, and intraocular pressure (IOP), were measured at rest and during VM. Results: VM did not have any significant influence on AL, subfoveal and peripapillary choroidal thickness, optic disc area, rim area, cup area, cup-to-disc area ratio, vertical cup-to-disc ratio, rim volume, cup volume, and nerve head volume measurements (for all; p >0.05). IOP and PD significantly increased during VM (for both; p <0.001). VM significantly decreased CCT, ACD, ACA, and ACV values (for all; p <0.001). Moreover, the optic nerve cup volume decreased and the horizontal cup-to-disc ratio significantly increased during VM (for both; p <0.05). Conclusions: VM may cause transient changes in IOP, optic disc morphology, and anterior chamber parameters. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000400209 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000400209 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0004-2749.20160061 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.79 n.4 2016 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209029016518656 |