A new unity for angular measurements in strabismus

Detalhes bibliográficos
Autor(a) principal: Bicas,Harley E. A.
Data de Publicação: 2014
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000500275
Resumo: The practical advantages of quantifying an angle by a ratio of linear lengths instead of arcs of circles has led to the definition of the prism-diopter, a conventional unity for numbering prisms and measuring strabismic deviations. However, a major inconvenience of using prism-diopter unities to express angular measurements is the non-linearity of the scale, which reaches an infinite value for the angle of 90º, then becomes negative, with decreasing magnitudes for increasing angles between 90º and 180º. As a consequence, arithmetical operations and comparisons of angles measured by such unities present errors of very great magnitudes. In order to retain the advantages of defining an angle by straight line dimensions but to diminish the severe inconveniences of this method, a new definition of the prism-diopter is proposed. Here, instead of defining the prism-diopter by the asymmetrical condition, the conception of this new unity is based on a geometrically symmetrical condition; that of the relationship of an isosceles triangle (where the leg is perpendicular to the bisector of the angle and the bisector itself ). The condition of symmetry for the definition of the new unity represents a conceptual advance because it reproduces the already well accepted, conventional criteria for quantifying the value of a prism, that of its minimum deviation. Furthermore, it corresponds to the most commonly observed clinical conditions of binocular balance. The absolute differences between the unitary values of the prism-diopter and that of the new unity are negligible (0.0025%), but the scale of values expressed by the new unity is closer to the ideal scale of angular measurements. (With the new unity, the infinite value is only reached for an angle of 180º and the errors due to arithmetical operations are much smaller.) Numerical examples showing the advantages of using the new unity of angular measurements instead of the prism-diopter are presented. A mathematical generalization of the modifying concept (partition of an angle) with which the new unity is based is also provided.
id CBO-2_3fcba3af60c46eebf0d7009ce89b0f0a
oai_identifier_str oai:scielo:S0004-27492014000500275
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling A new unity for angular measurements in strabismusStrabismusVisual cortexConvergence, ocularMeasuresThe practical advantages of quantifying an angle by a ratio of linear lengths instead of arcs of circles has led to the definition of the prism-diopter, a conventional unity for numbering prisms and measuring strabismic deviations. However, a major inconvenience of using prism-diopter unities to express angular measurements is the non-linearity of the scale, which reaches an infinite value for the angle of 90º, then becomes negative, with decreasing magnitudes for increasing angles between 90º and 180º. As a consequence, arithmetical operations and comparisons of angles measured by such unities present errors of very great magnitudes. In order to retain the advantages of defining an angle by straight line dimensions but to diminish the severe inconveniences of this method, a new definition of the prism-diopter is proposed. Here, instead of defining the prism-diopter by the asymmetrical condition, the conception of this new unity is based on a geometrically symmetrical condition; that of the relationship of an isosceles triangle (where the leg is perpendicular to the bisector of the angle and the bisector itself ). The condition of symmetry for the definition of the new unity represents a conceptual advance because it reproduces the already well accepted, conventional criteria for quantifying the value of a prism, that of its minimum deviation. Furthermore, it corresponds to the most commonly observed clinical conditions of binocular balance. The absolute differences between the unitary values of the prism-diopter and that of the new unity are negligible (0.0025%), but the scale of values expressed by the new unity is closer to the ideal scale of angular measurements. (With the new unity, the infinite value is only reached for an angle of 180º and the errors due to arithmetical operations are much smaller.) Numerical examples showing the advantages of using the new unity of angular measurements instead of the prism-diopter are presented. A mathematical generalization of the modifying concept (partition of an angle) with which the new unity is based is also provided.Conselho Brasileiro de Oftalmologia2014-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000500275Arquivos Brasileiros de Oftalmologia v.77 n.5 2014reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20140070info:eu-repo/semantics/openAccessBicas,Harley E. A.eng2015-04-10T00:00:00Zoai:scielo:S0004-27492014000500275Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2015-04-10T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv A new unity for angular measurements in strabismus
title A new unity for angular measurements in strabismus
spellingShingle A new unity for angular measurements in strabismus
Bicas,Harley E. A.
Strabismus
Visual cortex
Convergence, ocular
Measures
title_short A new unity for angular measurements in strabismus
title_full A new unity for angular measurements in strabismus
title_fullStr A new unity for angular measurements in strabismus
title_full_unstemmed A new unity for angular measurements in strabismus
title_sort A new unity for angular measurements in strabismus
author Bicas,Harley E. A.
author_facet Bicas,Harley E. A.
author_role author
dc.contributor.author.fl_str_mv Bicas,Harley E. A.
dc.subject.por.fl_str_mv Strabismus
Visual cortex
Convergence, ocular
Measures
topic Strabismus
Visual cortex
Convergence, ocular
Measures
description The practical advantages of quantifying an angle by a ratio of linear lengths instead of arcs of circles has led to the definition of the prism-diopter, a conventional unity for numbering prisms and measuring strabismic deviations. However, a major inconvenience of using prism-diopter unities to express angular measurements is the non-linearity of the scale, which reaches an infinite value for the angle of 90º, then becomes negative, with decreasing magnitudes for increasing angles between 90º and 180º. As a consequence, arithmetical operations and comparisons of angles measured by such unities present errors of very great magnitudes. In order to retain the advantages of defining an angle by straight line dimensions but to diminish the severe inconveniences of this method, a new definition of the prism-diopter is proposed. Here, instead of defining the prism-diopter by the asymmetrical condition, the conception of this new unity is based on a geometrically symmetrical condition; that of the relationship of an isosceles triangle (where the leg is perpendicular to the bisector of the angle and the bisector itself ). The condition of symmetry for the definition of the new unity represents a conceptual advance because it reproduces the already well accepted, conventional criteria for quantifying the value of a prism, that of its minimum deviation. Furthermore, it corresponds to the most commonly observed clinical conditions of binocular balance. The absolute differences between the unitary values of the prism-diopter and that of the new unity are negligible (0.0025%), but the scale of values expressed by the new unity is closer to the ideal scale of angular measurements. (With the new unity, the infinite value is only reached for an angle of 180º and the errors due to arithmetical operations are much smaller.) Numerical examples showing the advantages of using the new unity of angular measurements instead of the prism-diopter are presented. A mathematical generalization of the modifying concept (partition of an angle) with which the new unity is based is also provided.
publishDate 2014
dc.date.none.fl_str_mv 2014-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000500275
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000500275
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20140070
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.77 n.5 2014
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209028184997888