Optical biometry-based axial length alterations after intravitreal dexamethasone implant

Detalhes bibliográficos
Autor(a) principal: Ozal,Sadık Altan
Data de Publicação: 2019
Outros Autores: Kupelı,Ayca, Ozal,Ece, Gurlu,Vuslat
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000300006
Resumo: ABSTRACT Purpose: To investigate changes in axial length after intravitreal dexamethasone implantation in patients with macular edema. Methods: We performed a prospective comparative study of 46 patients with unilateral macular edema, due to diabetic retinopathy, retinal vein occlusion, and non-infectious uveitis, who underwent dexamethasone implantation. The fellow eyes of the patients were considered the control group. The central macular thickness was measured by spectral-domain optical coherence tomography, and axial length was measured by IOLMaster 700 optical coherence biometry. We compared axial length and central macular thickness values within the groups. Results: In the study group, the baseline central macular thickness was 460.19 ± 128.64 mm, significantly decreasing to 324.00 ± 79.84 mm after dexamethasone implantation (p=0.000). No significant change in central macular thickness measurements was seen in the control group (p=0.244). In the study group, the baseline axial length was 23.16 ± 0.68 mm, significantly increasing to 23.22 ± 0.65 mm after dexamethasone implantation (p=0.039). However, the control group exhibited no significant change in axial length (p=0.123). Conclusions: In addition to significantly reducing central macular thickness measurements, intravitreal dexamethasone implantation also significantly changes optical biometry-based axial length measurements.
id CBO-2_55714a05fa8bf2de512cd8f3664da861
oai_identifier_str oai:scielo:S0004-27492019000300006
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Optical biometry-based axial length alterations after intravitreal dexamethasone implantAxial length, eyeDexamethasone/administration & dosageIntravitreal injections, Drug implantsMacular edemaABSTRACT Purpose: To investigate changes in axial length after intravitreal dexamethasone implantation in patients with macular edema. Methods: We performed a prospective comparative study of 46 patients with unilateral macular edema, due to diabetic retinopathy, retinal vein occlusion, and non-infectious uveitis, who underwent dexamethasone implantation. The fellow eyes of the patients were considered the control group. The central macular thickness was measured by spectral-domain optical coherence tomography, and axial length was measured by IOLMaster 700 optical coherence biometry. We compared axial length and central macular thickness values within the groups. Results: In the study group, the baseline central macular thickness was 460.19 ± 128.64 mm, significantly decreasing to 324.00 ± 79.84 mm after dexamethasone implantation (p=0.000). No significant change in central macular thickness measurements was seen in the control group (p=0.244). In the study group, the baseline axial length was 23.16 ± 0.68 mm, significantly increasing to 23.22 ± 0.65 mm after dexamethasone implantation (p=0.039). However, the control group exhibited no significant change in axial length (p=0.123). Conclusions: In addition to significantly reducing central macular thickness measurements, intravitreal dexamethasone implantation also significantly changes optical biometry-based axial length measurements.Conselho Brasileiro de Oftalmologia2019-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000300006Arquivos Brasileiros de Oftalmologia v.82 n.3 2019reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20190040info:eu-repo/semantics/openAccessOzal,Sadık AltanKupelı,AycaOzal,EceGurlu,Vuslateng2019-05-13T00:00:00Zoai:scielo:S0004-27492019000300006Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2019-05-13T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Optical biometry-based axial length alterations after intravitreal dexamethasone implant
title Optical biometry-based axial length alterations after intravitreal dexamethasone implant
spellingShingle Optical biometry-based axial length alterations after intravitreal dexamethasone implant
Ozal,Sadık Altan
Axial length, eye
Dexamethasone/administration & dosage
Intravitreal injections, Drug implants
Macular edema
title_short Optical biometry-based axial length alterations after intravitreal dexamethasone implant
title_full Optical biometry-based axial length alterations after intravitreal dexamethasone implant
title_fullStr Optical biometry-based axial length alterations after intravitreal dexamethasone implant
title_full_unstemmed Optical biometry-based axial length alterations after intravitreal dexamethasone implant
title_sort Optical biometry-based axial length alterations after intravitreal dexamethasone implant
author Ozal,Sadık Altan
author_facet Ozal,Sadık Altan
Kupelı,Ayca
Ozal,Ece
Gurlu,Vuslat
author_role author
author2 Kupelı,Ayca
Ozal,Ece
Gurlu,Vuslat
author2_role author
author
author
dc.contributor.author.fl_str_mv Ozal,Sadık Altan
Kupelı,Ayca
Ozal,Ece
Gurlu,Vuslat
dc.subject.por.fl_str_mv Axial length, eye
Dexamethasone/administration & dosage
Intravitreal injections, Drug implants
Macular edema
topic Axial length, eye
Dexamethasone/administration & dosage
Intravitreal injections, Drug implants
Macular edema
description ABSTRACT Purpose: To investigate changes in axial length after intravitreal dexamethasone implantation in patients with macular edema. Methods: We performed a prospective comparative study of 46 patients with unilateral macular edema, due to diabetic retinopathy, retinal vein occlusion, and non-infectious uveitis, who underwent dexamethasone implantation. The fellow eyes of the patients were considered the control group. The central macular thickness was measured by spectral-domain optical coherence tomography, and axial length was measured by IOLMaster 700 optical coherence biometry. We compared axial length and central macular thickness values within the groups. Results: In the study group, the baseline central macular thickness was 460.19 ± 128.64 mm, significantly decreasing to 324.00 ± 79.84 mm after dexamethasone implantation (p=0.000). No significant change in central macular thickness measurements was seen in the control group (p=0.244). In the study group, the baseline axial length was 23.16 ± 0.68 mm, significantly increasing to 23.22 ± 0.65 mm after dexamethasone implantation (p=0.039). However, the control group exhibited no significant change in axial length (p=0.123). Conclusions: In addition to significantly reducing central macular thickness measurements, intravitreal dexamethasone implantation also significantly changes optical biometry-based axial length measurements.
publishDate 2019
dc.date.none.fl_str_mv 2019-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000300006
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000300006
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20190040
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.82 n.3 2019
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209030344015872