Visual field (Octopus 1-2-3) in normal subjects divided into homogeneous age-groups

Detalhes bibliográficos
Autor(a) principal: Calixto,Nassim
Data de Publicação: 2006
Outros Autores: Santos,Roberto Márcio de Oliveira, Cronemberger,Sebastião
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492006000500003
Resumo: PURPOSE: To determine the values in decibels of retinal sensitivity within the central 26 degrees of the visual field of normal subjects divided into homogenous age groups using the Octopus 1-2-3; to compare the values of retinal sensitivity we have found with those considered normal in the statistical package obtained by a multicenter study performed in 1994 with Octopus 201. METHODS: 181 subjects divided into 6 homogeneous age groups (10 to 19 yr; 20 to 29 yr; 30 to 39 yr; 40 to 49 yr; 50 to 59 yr and 60 year-old or older) were evaluated. Data on visual sensitivity and age, average sensitivity of central and paracentral regions and eccentricity were calculated. RESULTS: The average visual sensitivity of all groups was 26.77 ± 1.74 dB. Correlation between visual sensitivity and age evaluated by linear regression was 28.4 - 0.040 x (age) for the whole sample and 28.7 - 0.050 x (age) for subjects aged 20 or more. Sensitivity reduction by eccentricity was -0.30 dB/degree for the whole sample and for subjects aged 20 or more. CONCLUSIONS: Correlation between retinal sensitivity values and age based on the autoperimeter Octopus 201 (average sensitivity of 31.2 - 0.064 x age) is different from that found in this study: average sensitivity of 28.4 - 0.040 x (age) for the whole sample; 28.7 - 0.050 x (age) for subjects aged 20 or more. Values obtained with the Octopus 1-2-3 autoperimeter cannot be compared with those by other Octopus models (101, 201 and 500) due to their distinct features.
id CBO-2_6ab25504e38c2d2980f06c5a613fe18b
oai_identifier_str oai:scielo:S0004-27492006000500003
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Visual field (Octopus 1-2-3) in normal subjects divided into homogeneous age-groupsPerimetry/instrumentationPerimetry/statistic and numerical dataVisual fields/physiologyAge groupsSensory thresholdAging/physiologyPURPOSE: To determine the values in decibels of retinal sensitivity within the central 26 degrees of the visual field of normal subjects divided into homogenous age groups using the Octopus 1-2-3; to compare the values of retinal sensitivity we have found with those considered normal in the statistical package obtained by a multicenter study performed in 1994 with Octopus 201. METHODS: 181 subjects divided into 6 homogeneous age groups (10 to 19 yr; 20 to 29 yr; 30 to 39 yr; 40 to 49 yr; 50 to 59 yr and 60 year-old or older) were evaluated. Data on visual sensitivity and age, average sensitivity of central and paracentral regions and eccentricity were calculated. RESULTS: The average visual sensitivity of all groups was 26.77 ± 1.74 dB. Correlation between visual sensitivity and age evaluated by linear regression was 28.4 - 0.040 x (age) for the whole sample and 28.7 - 0.050 x (age) for subjects aged 20 or more. Sensitivity reduction by eccentricity was -0.30 dB/degree for the whole sample and for subjects aged 20 or more. CONCLUSIONS: Correlation between retinal sensitivity values and age based on the autoperimeter Octopus 201 (average sensitivity of 31.2 - 0.064 x age) is different from that found in this study: average sensitivity of 28.4 - 0.040 x (age) for the whole sample; 28.7 - 0.050 x (age) for subjects aged 20 or more. Values obtained with the Octopus 1-2-3 autoperimeter cannot be compared with those by other Octopus models (101, 201 and 500) due to their distinct features.Conselho Brasileiro de Oftalmologia2006-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492006000500003Arquivos Brasileiros de Oftalmologia v.69 n.5 2006reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492006000500003info:eu-repo/semantics/openAccessCalixto,NassimSantos,Roberto Márcio de OliveiraCronemberger,Sebastiãoeng2006-12-15T00:00:00Zoai:scielo:S0004-27492006000500003Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2006-12-15T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Visual field (Octopus 1-2-3) in normal subjects divided into homogeneous age-groups
title Visual field (Octopus 1-2-3) in normal subjects divided into homogeneous age-groups
spellingShingle Visual field (Octopus 1-2-3) in normal subjects divided into homogeneous age-groups
Calixto,Nassim
Perimetry/instrumentation
Perimetry/statistic and numerical data
Visual fields/physiology
Age groups
Sensory threshold
Aging/physiology
title_short Visual field (Octopus 1-2-3) in normal subjects divided into homogeneous age-groups
title_full Visual field (Octopus 1-2-3) in normal subjects divided into homogeneous age-groups
title_fullStr Visual field (Octopus 1-2-3) in normal subjects divided into homogeneous age-groups
title_full_unstemmed Visual field (Octopus 1-2-3) in normal subjects divided into homogeneous age-groups
title_sort Visual field (Octopus 1-2-3) in normal subjects divided into homogeneous age-groups
author Calixto,Nassim
author_facet Calixto,Nassim
Santos,Roberto Márcio de Oliveira
Cronemberger,Sebastião
author_role author
author2 Santos,Roberto Márcio de Oliveira
Cronemberger,Sebastião
author2_role author
author
dc.contributor.author.fl_str_mv Calixto,Nassim
Santos,Roberto Márcio de Oliveira
Cronemberger,Sebastião
dc.subject.por.fl_str_mv Perimetry/instrumentation
Perimetry/statistic and numerical data
Visual fields/physiology
Age groups
Sensory threshold
Aging/physiology
topic Perimetry/instrumentation
Perimetry/statistic and numerical data
Visual fields/physiology
Age groups
Sensory threshold
Aging/physiology
description PURPOSE: To determine the values in decibels of retinal sensitivity within the central 26 degrees of the visual field of normal subjects divided into homogenous age groups using the Octopus 1-2-3; to compare the values of retinal sensitivity we have found with those considered normal in the statistical package obtained by a multicenter study performed in 1994 with Octopus 201. METHODS: 181 subjects divided into 6 homogeneous age groups (10 to 19 yr; 20 to 29 yr; 30 to 39 yr; 40 to 49 yr; 50 to 59 yr and 60 year-old or older) were evaluated. Data on visual sensitivity and age, average sensitivity of central and paracentral regions and eccentricity were calculated. RESULTS: The average visual sensitivity of all groups was 26.77 ± 1.74 dB. Correlation between visual sensitivity and age evaluated by linear regression was 28.4 - 0.040 x (age) for the whole sample and 28.7 - 0.050 x (age) for subjects aged 20 or more. Sensitivity reduction by eccentricity was -0.30 dB/degree for the whole sample and for subjects aged 20 or more. CONCLUSIONS: Correlation between retinal sensitivity values and age based on the autoperimeter Octopus 201 (average sensitivity of 31.2 - 0.064 x age) is different from that found in this study: average sensitivity of 28.4 - 0.040 x (age) for the whole sample; 28.7 - 0.050 x (age) for subjects aged 20 or more. Values obtained with the Octopus 1-2-3 autoperimeter cannot be compared with those by other Octopus models (101, 201 and 500) due to their distinct features.
publishDate 2006
dc.date.none.fl_str_mv 2006-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492006000500003
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492006000500003
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0004-27492006000500003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.69 n.5 2006
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209023752667136