Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems

Detalhes bibliográficos
Autor(a) principal: Inan,Umit Ubeyt
Data de Publicação: 2016
Outros Autores: Polat,Onur, Inan,Sibel, Yigit,Safiye, Baysal,Zeki
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000100006
Resumo: ABSTRACT Purpose: To compare the pain responses of patients with proliferative diabetic retinopathy (PDR) undergoing panretinal photocoagulation (PRP) using either pattern scan laser (PASCAL) or navigated laser photocoagulation (NAVILAS). Methods: Patients diagnosed with PDR were randomly assigned to undergo either PASCAL or NAVILAS photocoagulation treatment. PRP was performed using the multi-shot mode with a spot size of 200-400 µm and a pulse duration of 30 ms to obtain a white-grayish spot on the retina. Parameters were identical in both procedures. After 30 min of PRP application, patients were asked to verbally describe their pain perception as either "none," "mild," "moderate," "severe," or "very severe" using a verbal rating scale (VRS) and visual analog scale (VAS) by indicating a score from "0" to "10," representing the severity of pain from "no pain" to "severe pain." Results: A total of 60 eyes of 60 patients (20 females and 40 males) diagnosed with PDR were treated. The mean age of patients was 62.22 ± 9.19 years, and the mean diabetes duration was 195.47 ± 94.54 months. The mean number of laser spots delivered during PRP was 389.47 ± 71.52 in the NAVILAS group and 392.70 ± 54.33 in the PASCAL group (p=0.57). The difference in pain responses between patients in the NAVILAS and PASCAL groups was significant with regard to the mean VRS (1.10 ± 0.67 and 1.47 ± 0.69, respectively; p=0.042) and mean VAS (2.13 ± 1.17 and 2.97 ± 1.35, respectively; p=0.034) scores. Conclusions: Pain responses in patients undergoing PRP with a 30-ms pulse duration were significantly milder in the NAVILAS group than in the PASCAL group.
id CBO-2_a4aa6861036818c108956816f8791e61
oai_identifier_str oai:scielo:S0004-27492016000100006
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systemsDiabetic retinopathyEquipment designLaser coagulationPain measurementABSTRACT Purpose: To compare the pain responses of patients with proliferative diabetic retinopathy (PDR) undergoing panretinal photocoagulation (PRP) using either pattern scan laser (PASCAL) or navigated laser photocoagulation (NAVILAS). Methods: Patients diagnosed with PDR were randomly assigned to undergo either PASCAL or NAVILAS photocoagulation treatment. PRP was performed using the multi-shot mode with a spot size of 200-400 µm and a pulse duration of 30 ms to obtain a white-grayish spot on the retina. Parameters were identical in both procedures. After 30 min of PRP application, patients were asked to verbally describe their pain perception as either "none," "mild," "moderate," "severe," or "very severe" using a verbal rating scale (VRS) and visual analog scale (VAS) by indicating a score from "0" to "10," representing the severity of pain from "no pain" to "severe pain." Results: A total of 60 eyes of 60 patients (20 females and 40 males) diagnosed with PDR were treated. The mean age of patients was 62.22 ± 9.19 years, and the mean diabetes duration was 195.47 ± 94.54 months. The mean number of laser spots delivered during PRP was 389.47 ± 71.52 in the NAVILAS group and 392.70 ± 54.33 in the PASCAL group (p=0.57). The difference in pain responses between patients in the NAVILAS and PASCAL groups was significant with regard to the mean VRS (1.10 ± 0.67 and 1.47 ± 0.69, respectively; p=0.042) and mean VAS (2.13 ± 1.17 and 2.97 ± 1.35, respectively; p=0.034) scores. Conclusions: Pain responses in patients undergoing PRP with a 30-ms pulse duration were significantly milder in the NAVILAS group than in the PASCAL group.Conselho Brasileiro de Oftalmologia2016-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000100006Arquivos Brasileiros de Oftalmologia v.79 n.1 2016reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20160006info:eu-repo/semantics/openAccessInan,Umit UbeytPolat,OnurInan,SibelYigit,SafiyeBaysal,Zekieng2016-01-26T00:00:00Zoai:scielo:S0004-27492016000100006Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2016-01-26T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems
title Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems
spellingShingle Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems
Inan,Umit Ubeyt
Diabetic retinopathy
Equipment design
Laser coagulation
Pain measurement
title_short Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems
title_full Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems
title_fullStr Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems
title_full_unstemmed Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems
title_sort Comparison of pain scores between patients undergoing panretinal photocoagulation using navigated or pattern scan laser systems
author Inan,Umit Ubeyt
author_facet Inan,Umit Ubeyt
Polat,Onur
Inan,Sibel
Yigit,Safiye
Baysal,Zeki
author_role author
author2 Polat,Onur
Inan,Sibel
Yigit,Safiye
Baysal,Zeki
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Inan,Umit Ubeyt
Polat,Onur
Inan,Sibel
Yigit,Safiye
Baysal,Zeki
dc.subject.por.fl_str_mv Diabetic retinopathy
Equipment design
Laser coagulation
Pain measurement
topic Diabetic retinopathy
Equipment design
Laser coagulation
Pain measurement
description ABSTRACT Purpose: To compare the pain responses of patients with proliferative diabetic retinopathy (PDR) undergoing panretinal photocoagulation (PRP) using either pattern scan laser (PASCAL) or navigated laser photocoagulation (NAVILAS). Methods: Patients diagnosed with PDR were randomly assigned to undergo either PASCAL or NAVILAS photocoagulation treatment. PRP was performed using the multi-shot mode with a spot size of 200-400 µm and a pulse duration of 30 ms to obtain a white-grayish spot on the retina. Parameters were identical in both procedures. After 30 min of PRP application, patients were asked to verbally describe their pain perception as either "none," "mild," "moderate," "severe," or "very severe" using a verbal rating scale (VRS) and visual analog scale (VAS) by indicating a score from "0" to "10," representing the severity of pain from "no pain" to "severe pain." Results: A total of 60 eyes of 60 patients (20 females and 40 males) diagnosed with PDR were treated. The mean age of patients was 62.22 ± 9.19 years, and the mean diabetes duration was 195.47 ± 94.54 months. The mean number of laser spots delivered during PRP was 389.47 ± 71.52 in the NAVILAS group and 392.70 ± 54.33 in the PASCAL group (p=0.57). The difference in pain responses between patients in the NAVILAS and PASCAL groups was significant with regard to the mean VRS (1.10 ± 0.67 and 1.47 ± 0.69, respectively; p=0.042) and mean VAS (2.13 ± 1.17 and 2.97 ± 1.35, respectively; p=0.034) scores. Conclusions: Pain responses in patients undergoing PRP with a 30-ms pulse duration were significantly milder in the NAVILAS group than in the PASCAL group.
publishDate 2016
dc.date.none.fl_str_mv 2016-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000100006
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492016000100006
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20160006
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.79 n.1 2016
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209028673634304