Resumo: Purpose: To determine the horizontal corneal diameter, central corneal thickness, and axial length in premature infants. Methods: Infants with a birth weight of less than 2,500 g or with a gestation period of less than 36 weeks were included in the study. Infants with retinopathy of prematurity (ROP) were allocated to Group 1 (n=138), while those without ROP were allocated to Group 2 (n=236). All infants underwent a complete ophthalmologic examination, including corneal diameter measurements, pachymetry, biometry, and fundoscopy. Between-group comparisons of horizontal corneal diameter, central corneal thickness, and axial lengths were performed. Independent sample t-tests were used for statistical analysis. Results: Data was obtained from 374 eyes of 187 infants (102 female, 85 male). The mean gestational age at birth was 30.7 ± 2.7 weeks (range 25-36 weeks), the mean birth weight was 1,514 ± 533.3 g (range 750-1,970 g), and the mean postmenstrual age at examination was 40.0 ± 4.8 weeks. The mean gestational age and the mean birth weight of Group 1 were statistically lower than Group 2 (p<0.05). There were no significant differences in horizontal corneal diameter, central corneal thickness, and axial length between the two groups (p>0.05). Conclusions: The presence of ROP in premature infants does not alter the horizontal corneal diameter, central corneal thickness, or axial length.
id CBO-2_bc9c56efbc1acc3783f40e132d7e62df
oai_identifier_str oai:scielo:S0004-27492014000400225
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infantsCornea/anatomy and histologyRetinopathy of prematurityInfant, prematureBirth weightGestational age Purpose: To determine the horizontal corneal diameter, central corneal thickness, and axial length in premature infants. Methods: Infants with a birth weight of less than 2,500 g or with a gestation period of less than 36 weeks were included in the study. Infants with retinopathy of prematurity (ROP) were allocated to Group 1 (n=138), while those without ROP were allocated to Group 2 (n=236). All infants underwent a complete ophthalmologic examination, including corneal diameter measurements, pachymetry, biometry, and fundoscopy. Between-group comparisons of horizontal corneal diameter, central corneal thickness, and axial lengths were performed. Independent sample t-tests were used for statistical analysis. Results: Data was obtained from 374 eyes of 187 infants (102 female, 85 male). The mean gestational age at birth was 30.7 ± 2.7 weeks (range 25-36 weeks), the mean birth weight was 1,514 ± 533.3 g (range 750-1,970 g), and the mean postmenstrual age at examination was 40.0 ± 4.8 weeks. The mean gestational age and the mean birth weight of Group 1 were statistically lower than Group 2 (p<0.05). There were no significant differences in horizontal corneal diameter, central corneal thickness, and axial length between the two groups (p>0.05). Conclusions: The presence of ROP in premature infants does not alter the horizontal corneal diameter, central corneal thickness, or axial length. Conselho Brasileiro de Oftalmologia2014-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400225Arquivos Brasileiros de Oftalmologia v.77 n.4 2014reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20140058info:eu-repo/semantics/openAccessOzdemir,OzdemirTunay,Zuhal ÖzenPetriçli,Ikbal SezaAcar,Damla ErgintürkAcar,UgurErol,Muhammet Kazimeng2014-11-13T00:00:00Zoai:scielo:S0004-27492014000400225Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2014-11-13T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants
title Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants
spellingShingle Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants
Ozdemir,Ozdemir
Cornea/anatomy and histology
Retinopathy of prematurity
Infant, premature
Birth weight
Gestational age
title_short Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants
title_full Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants
title_fullStr Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants
title_full_unstemmed Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants
title_sort Analysis of the horizontal corneal diameter, central corneal thickness, and axial length in premature infants
author Ozdemir,Ozdemir
author_facet Ozdemir,Ozdemir
Tunay,Zuhal Özen
Petriçli,Ikbal Seza
Acar,Damla Ergintürk
Acar,Ugur
Erol,Muhammet Kazim
author_role author
author2 Tunay,Zuhal Özen
Petriçli,Ikbal Seza
Acar,Damla Ergintürk
Acar,Ugur
Erol,Muhammet Kazim
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Ozdemir,Ozdemir
Tunay,Zuhal Özen
Petriçli,Ikbal Seza
Acar,Damla Ergintürk
Acar,Ugur
Erol,Muhammet Kazim
dc.subject.por.fl_str_mv Cornea/anatomy and histology
Retinopathy of prematurity
Infant, premature
Birth weight
Gestational age
topic Cornea/anatomy and histology
Retinopathy of prematurity
Infant, premature
Birth weight
Gestational age
description Purpose: To determine the horizontal corneal diameter, central corneal thickness, and axial length in premature infants. Methods: Infants with a birth weight of less than 2,500 g or with a gestation period of less than 36 weeks were included in the study. Infants with retinopathy of prematurity (ROP) were allocated to Group 1 (n=138), while those without ROP were allocated to Group 2 (n=236). All infants underwent a complete ophthalmologic examination, including corneal diameter measurements, pachymetry, biometry, and fundoscopy. Between-group comparisons of horizontal corneal diameter, central corneal thickness, and axial lengths were performed. Independent sample t-tests were used for statistical analysis. Results: Data was obtained from 374 eyes of 187 infants (102 female, 85 male). The mean gestational age at birth was 30.7 ± 2.7 weeks (range 25-36 weeks), the mean birth weight was 1,514 ± 533.3 g (range 750-1,970 g), and the mean postmenstrual age at examination was 40.0 ± 4.8 weeks. The mean gestational age and the mean birth weight of Group 1 were statistically lower than Group 2 (p<0.05). There were no significant differences in horizontal corneal diameter, central corneal thickness, and axial length between the two groups (p>0.05). Conclusions: The presence of ROP in premature infants does not alter the horizontal corneal diameter, central corneal thickness, or axial length.
publishDate 2014
dc.date.none.fl_str_mv 2014-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400225
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000400225
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20140058
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.77 n.4 2014
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209028160880640