Effects of axial length on retinal nerve fiber layer and macular ganglion cell-inner plexiform layer measured by spectral-domain OCT
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492020000400269 |
Resumo: | ABSTRACT Purpose: To evaluate the influence of ocular axial length on circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in healthy eyes after correcting for ocular magnification effect. Methods: In this cross-sectional study, we evaluated 120 eyes from 60 volunteer participants (myopes, emmetropes, and hyperopes). The thickness of the circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer were measured using the spectral optical coherence tomography (OCT)-Cirrus HD-OCT and correlated with ocular axial length. Adjustment for ocular magnification was performed by applying Littmann’s formula. Results: Before the adjustment for ocular magnification, age-adjusted mixed models analysis demonstrated a significant negative correlation between axial length and average circumpapillary retinal nerve fiber layer thickness (r=-0.43, p<0.001), inferior circumpapillary retinal nerve fiber layer thickness (r=-0.46, p<0.001), superior circumpapillary retinal nerve fiber layer thickness (r=-0.31, p<0.05), nasal circumpapillary retinal nerve fiber layer thickness (r=-0.35, p<0.001), and average ganglion cell-inner plexiform layer thickness (r=-0.35, p<0.05). However, after correcting for magnification effect, the results were considerably different, revealing only a positive correlation between axial length and temporal retinal nerve fiber layer thickness (r=0.42, p<0.001). Additionally, we demonstrated a positive correlation between axial length and average ganglion cell-inner plexiform layer thickness (r=0.48, p<0.001). All other correlations were not found to be statistically significant. Conclusions: Before adjustment for ocular magnification, axial length was negatively correlated with circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness measured by Cirrus-OCT. We attributed this effect to ocular magnification associated with greater axial lengths, which was corrected with the Littman’s formula. Further studies are required to investigate the impact of ocular magnification correction on the diagnostic accuracy of Cirrus-OCT. |
id |
CBO-2_d8066fe2bc58f17dc441926a3eecac19 |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492020000400269 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Effects of axial length on retinal nerve fiber layer and macular ganglion cell-inner plexiform layer measured by spectral-domain OCTTomography, optical coherenceRetinal ganglion cellsAxial length, eyeABSTRACT Purpose: To evaluate the influence of ocular axial length on circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in healthy eyes after correcting for ocular magnification effect. Methods: In this cross-sectional study, we evaluated 120 eyes from 60 volunteer participants (myopes, emmetropes, and hyperopes). The thickness of the circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer were measured using the spectral optical coherence tomography (OCT)-Cirrus HD-OCT and correlated with ocular axial length. Adjustment for ocular magnification was performed by applying Littmann’s formula. Results: Before the adjustment for ocular magnification, age-adjusted mixed models analysis demonstrated a significant negative correlation between axial length and average circumpapillary retinal nerve fiber layer thickness (r=-0.43, p<0.001), inferior circumpapillary retinal nerve fiber layer thickness (r=-0.46, p<0.001), superior circumpapillary retinal nerve fiber layer thickness (r=-0.31, p<0.05), nasal circumpapillary retinal nerve fiber layer thickness (r=-0.35, p<0.001), and average ganglion cell-inner plexiform layer thickness (r=-0.35, p<0.05). However, after correcting for magnification effect, the results were considerably different, revealing only a positive correlation between axial length and temporal retinal nerve fiber layer thickness (r=0.42, p<0.001). Additionally, we demonstrated a positive correlation between axial length and average ganglion cell-inner plexiform layer thickness (r=0.48, p<0.001). All other correlations were not found to be statistically significant. Conclusions: Before adjustment for ocular magnification, axial length was negatively correlated with circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness measured by Cirrus-OCT. We attributed this effect to ocular magnification associated with greater axial lengths, which was corrected with the Littman’s formula. Further studies are required to investigate the impact of ocular magnification correction on the diagnostic accuracy of Cirrus-OCT.Conselho Brasileiro de Oftalmologia2020-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492020000400269Arquivos Brasileiros de Oftalmologia v.83 n.4 2020reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20200039info:eu-repo/semantics/openAccessFrancisconi,Carolina Lampert MonteWagner,Mário BernardesRibeiro,Roberto Vanin PintoFreitas,André Moraeseng2020-07-27T00:00:00Zoai:scielo:S0004-27492020000400269Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2020-07-27T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Effects of axial length on retinal nerve fiber layer and macular ganglion cell-inner plexiform layer measured by spectral-domain OCT |
title |
Effects of axial length on retinal nerve fiber layer and macular ganglion cell-inner plexiform layer measured by spectral-domain OCT |
spellingShingle |
Effects of axial length on retinal nerve fiber layer and macular ganglion cell-inner plexiform layer measured by spectral-domain OCT Francisconi,Carolina Lampert Monte Tomography, optical coherence Retinal ganglion cells Axial length, eye |
title_short |
Effects of axial length on retinal nerve fiber layer and macular ganglion cell-inner plexiform layer measured by spectral-domain OCT |
title_full |
Effects of axial length on retinal nerve fiber layer and macular ganglion cell-inner plexiform layer measured by spectral-domain OCT |
title_fullStr |
Effects of axial length on retinal nerve fiber layer and macular ganglion cell-inner plexiform layer measured by spectral-domain OCT |
title_full_unstemmed |
Effects of axial length on retinal nerve fiber layer and macular ganglion cell-inner plexiform layer measured by spectral-domain OCT |
title_sort |
Effects of axial length on retinal nerve fiber layer and macular ganglion cell-inner plexiform layer measured by spectral-domain OCT |
author |
Francisconi,Carolina Lampert Monte |
author_facet |
Francisconi,Carolina Lampert Monte Wagner,Mário Bernardes Ribeiro,Roberto Vanin Pinto Freitas,André Moraes |
author_role |
author |
author2 |
Wagner,Mário Bernardes Ribeiro,Roberto Vanin Pinto Freitas,André Moraes |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Francisconi,Carolina Lampert Monte Wagner,Mário Bernardes Ribeiro,Roberto Vanin Pinto Freitas,André Moraes |
dc.subject.por.fl_str_mv |
Tomography, optical coherence Retinal ganglion cells Axial length, eye |
topic |
Tomography, optical coherence Retinal ganglion cells Axial length, eye |
description |
ABSTRACT Purpose: To evaluate the influence of ocular axial length on circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness in healthy eyes after correcting for ocular magnification effect. Methods: In this cross-sectional study, we evaluated 120 eyes from 60 volunteer participants (myopes, emmetropes, and hyperopes). The thickness of the circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer were measured using the spectral optical coherence tomography (OCT)-Cirrus HD-OCT and correlated with ocular axial length. Adjustment for ocular magnification was performed by applying Littmann’s formula. Results: Before the adjustment for ocular magnification, age-adjusted mixed models analysis demonstrated a significant negative correlation between axial length and average circumpapillary retinal nerve fiber layer thickness (r=-0.43, p<0.001), inferior circumpapillary retinal nerve fiber layer thickness (r=-0.46, p<0.001), superior circumpapillary retinal nerve fiber layer thickness (r=-0.31, p<0.05), nasal circumpapillary retinal nerve fiber layer thickness (r=-0.35, p<0.001), and average ganglion cell-inner plexiform layer thickness (r=-0.35, p<0.05). However, after correcting for magnification effect, the results were considerably different, revealing only a positive correlation between axial length and temporal retinal nerve fiber layer thickness (r=0.42, p<0.001). Additionally, we demonstrated a positive correlation between axial length and average ganglion cell-inner plexiform layer thickness (r=0.48, p<0.001). All other correlations were not found to be statistically significant. Conclusions: Before adjustment for ocular magnification, axial length was negatively correlated with circumpapillary retinal nerve fiber layer and ganglion cell-inner plexiform layer thickness measured by Cirrus-OCT. We attributed this effect to ocular magnification associated with greater axial lengths, which was corrected with the Littman’s formula. Further studies are required to investigate the impact of ocular magnification correction on the diagnostic accuracy of Cirrus-OCT. |
publishDate |
2020 |
dc.date.none.fl_str_mv |
2020-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492020000400269 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492020000400269 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0004-2749.20200039 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.83 n.4 2020 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209030774980608 |