Biometric relationships of ocular components in esotropic amblyopia

Detalhes bibliográficos
Autor(a) principal: Debert,Iara
Data de Publicação: 2012
Outros Autores: Polati,Mariza, Jesus,Daniela Lima de, Souza,Eliane Cardoso dos Santos, Alves,Milton Ruiz
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos brasileiros de oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000100008
Resumo: PURPOSE: To investigate the contribution of the individual ocular components, i.e. anterior chamber depth, lens thickness and vitreous chamber depth, to total axial length in patients with esotropic amblyopia. METHODS: The study population consisted of 74 children, aged between 5 and 8 years: thirty-seven patients with esotropic amblyopia and 37 healthy volunteers (control group). The participants underwent a comprehensive ophthalmological examination, including cycloplegic refraction and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. Paired Student's t-tests were used to compare biometric measurements between amblyopic eyes and their fellow eyes and between right and left eyes in the control group. To evaluate the contribution of the ocular components to the total axial length, we report the individual components as a percentage of total axial length. RESULTS: The comparison between amblyopic and fellow eyes regarding the individual contribution from ocular components to the total axial length revealed greater contribution from lens thickness (P=0.001) and smaller contribution from vitreous chamber depth (P=0.001) in amblyopic eyes, despite similar contribution from anterior chamber depth (P=0.434). The comparison between right and left eyes in the control group showed similar contributions from anterior chamber depth (P=0.620), lens thickness (P=0.721), and vitreous chamber depth (P=0.483). CONCLUSIONS: This study shows differences between amblyopic and non-amblyopic eyes when the total axial length is broken down into the individual contribution from the ocular components.
id CBO-2_e8b57cb9bfcac6de7c23395ec42eea10
oai_identifier_str oai:scielo:S0004-27492012000100008
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Biometric relationships of ocular components in esotropic amblyopiaAmblyopiaAxial lengtheyeLenscrystallineEsotropiaUltrasonographyPURPOSE: To investigate the contribution of the individual ocular components, i.e. anterior chamber depth, lens thickness and vitreous chamber depth, to total axial length in patients with esotropic amblyopia. METHODS: The study population consisted of 74 children, aged between 5 and 8 years: thirty-seven patients with esotropic amblyopia and 37 healthy volunteers (control group). The participants underwent a comprehensive ophthalmological examination, including cycloplegic refraction and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. Paired Student's t-tests were used to compare biometric measurements between amblyopic eyes and their fellow eyes and between right and left eyes in the control group. To evaluate the contribution of the ocular components to the total axial length, we report the individual components as a percentage of total axial length. RESULTS: The comparison between amblyopic and fellow eyes regarding the individual contribution from ocular components to the total axial length revealed greater contribution from lens thickness (P=0.001) and smaller contribution from vitreous chamber depth (P=0.001) in amblyopic eyes, despite similar contribution from anterior chamber depth (P=0.434). The comparison between right and left eyes in the control group showed similar contributions from anterior chamber depth (P=0.620), lens thickness (P=0.721), and vitreous chamber depth (P=0.483). CONCLUSIONS: This study shows differences between amblyopic and non-amblyopic eyes when the total axial length is broken down into the individual contribution from the ocular components.Conselho Brasileiro de Oftalmologia2012-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000100008Arquivos Brasileiros de Oftalmologia v.75 n.1 2012reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492012000100008info:eu-repo/semantics/openAccessDebert,IaraPolati,MarizaJesus,Daniela Lima deSouza,Eliane Cardoso dos SantosAlves,Milton Ruizeng2012-04-27T00:00:00Zoai:scielo:S0004-27492012000100008Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2012-04-27T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Biometric relationships of ocular components in esotropic amblyopia
title Biometric relationships of ocular components in esotropic amblyopia
spellingShingle Biometric relationships of ocular components in esotropic amblyopia
Debert,Iara
Amblyopia
Axial length
eye
Lens
crystalline
Esotropia
Ultrasonography
title_short Biometric relationships of ocular components in esotropic amblyopia
title_full Biometric relationships of ocular components in esotropic amblyopia
title_fullStr Biometric relationships of ocular components in esotropic amblyopia
title_full_unstemmed Biometric relationships of ocular components in esotropic amblyopia
title_sort Biometric relationships of ocular components in esotropic amblyopia
author Debert,Iara
author_facet Debert,Iara
Polati,Mariza
Jesus,Daniela Lima de
Souza,Eliane Cardoso dos Santos
Alves,Milton Ruiz
author_role author
author2 Polati,Mariza
Jesus,Daniela Lima de
Souza,Eliane Cardoso dos Santos
Alves,Milton Ruiz
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Debert,Iara
Polati,Mariza
Jesus,Daniela Lima de
Souza,Eliane Cardoso dos Santos
Alves,Milton Ruiz
dc.subject.por.fl_str_mv Amblyopia
Axial length
eye
Lens
crystalline
Esotropia
Ultrasonography
topic Amblyopia
Axial length
eye
Lens
crystalline
Esotropia
Ultrasonography
description PURPOSE: To investigate the contribution of the individual ocular components, i.e. anterior chamber depth, lens thickness and vitreous chamber depth, to total axial length in patients with esotropic amblyopia. METHODS: The study population consisted of 74 children, aged between 5 and 8 years: thirty-seven patients with esotropic amblyopia and 37 healthy volunteers (control group). The participants underwent a comprehensive ophthalmological examination, including cycloplegic refraction and A-scan ultrasonography. Anterior chamber depth, lens thickness, vitreous chamber depth and total axial length were recorded. Paired Student's t-tests were used to compare biometric measurements between amblyopic eyes and their fellow eyes and between right and left eyes in the control group. To evaluate the contribution of the ocular components to the total axial length, we report the individual components as a percentage of total axial length. RESULTS: The comparison between amblyopic and fellow eyes regarding the individual contribution from ocular components to the total axial length revealed greater contribution from lens thickness (P=0.001) and smaller contribution from vitreous chamber depth (P=0.001) in amblyopic eyes, despite similar contribution from anterior chamber depth (P=0.434). The comparison between right and left eyes in the control group showed similar contributions from anterior chamber depth (P=0.620), lens thickness (P=0.721), and vitreous chamber depth (P=0.483). CONCLUSIONS: This study shows differences between amblyopic and non-amblyopic eyes when the total axial length is broken down into the individual contribution from the ocular components.
publishDate 2012
dc.date.none.fl_str_mv 2012-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000100008
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492012000100008
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0004-27492012000100008
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.75 n.1 2012
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209027220307968