Biomechanical and histological evaluation of glycerol-preserved human sclerae
Autor(a) principal: | |
---|---|
Data de Publicação: | 2007 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492007000600019 |
Resumo: | PURPOSE: To determine the histological and biomechanical characteristics of glycerol-preserved human sclera. METHODS: A total of 114 paired human sclerae were cleaned and preserved with 98% glycerol under refrigeration at 4 to 8ºC. The samples were divided into a control group with no preservation and 5 groups of 19 sclerae in 7, 15, 30, 90 and 180 days of preservation. Each specimen was submitted to histological examination and tested for traction distensibility functions. RESULTS: Preservation in glycerol did not cause alterations in the histological architecture of the scleral tissue. The mean load required to break the scleral tissue increased according to preservation time as a sigmoid function. A significant increase in mechanical resistance and decrease in distension of scleral tissue occurred after 90 days of preservation. CONCLUSIONS: Scleral preservation in glycerol keeps tissue integrity. The preserved material is less distensible after 90 days. Surgeons who use sclera in ophthalmic procedures should be aware of the mechanical characteristics of glycerol-preserved sclera and take into account tissue preservation time. |
id |
CBO-2_f573580e85990df053075b47f34ea56f |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492007000600019 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Biomechanical and histological evaluation of glycerol-preserved human scleraeSclera/drug effectsGlycerolTissue preservationHistologyPURPOSE: To determine the histological and biomechanical characteristics of glycerol-preserved human sclera. METHODS: A total of 114 paired human sclerae were cleaned and preserved with 98% glycerol under refrigeration at 4 to 8ºC. The samples were divided into a control group with no preservation and 5 groups of 19 sclerae in 7, 15, 30, 90 and 180 days of preservation. Each specimen was submitted to histological examination and tested for traction distensibility functions. RESULTS: Preservation in glycerol did not cause alterations in the histological architecture of the scleral tissue. The mean load required to break the scleral tissue increased according to preservation time as a sigmoid function. A significant increase in mechanical resistance and decrease in distension of scleral tissue occurred after 90 days of preservation. CONCLUSIONS: Scleral preservation in glycerol keeps tissue integrity. The preserved material is less distensible after 90 days. Surgeons who use sclera in ophthalmic procedures should be aware of the mechanical characteristics of glycerol-preserved sclera and take into account tissue preservation time.Conselho Brasileiro de Oftalmologia2007-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492007000600019Arquivos Brasileiros de Oftalmologia v.70 n.6 2007reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492007000600019info:eu-repo/semantics/openAccessSchirmbeck,TarcisoCruz,Antonio Augusto Velasco eeng2008-01-22T00:00:00Zoai:scielo:S0004-27492007000600019Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2008-01-22T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Biomechanical and histological evaluation of glycerol-preserved human sclerae |
title |
Biomechanical and histological evaluation of glycerol-preserved human sclerae |
spellingShingle |
Biomechanical and histological evaluation of glycerol-preserved human sclerae Schirmbeck,Tarciso Sclera/drug effects Glycerol Tissue preservation Histology |
title_short |
Biomechanical and histological evaluation of glycerol-preserved human sclerae |
title_full |
Biomechanical and histological evaluation of glycerol-preserved human sclerae |
title_fullStr |
Biomechanical and histological evaluation of glycerol-preserved human sclerae |
title_full_unstemmed |
Biomechanical and histological evaluation of glycerol-preserved human sclerae |
title_sort |
Biomechanical and histological evaluation of glycerol-preserved human sclerae |
author |
Schirmbeck,Tarciso |
author_facet |
Schirmbeck,Tarciso Cruz,Antonio Augusto Velasco e |
author_role |
author |
author2 |
Cruz,Antonio Augusto Velasco e |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Schirmbeck,Tarciso Cruz,Antonio Augusto Velasco e |
dc.subject.por.fl_str_mv |
Sclera/drug effects Glycerol Tissue preservation Histology |
topic |
Sclera/drug effects Glycerol Tissue preservation Histology |
description |
PURPOSE: To determine the histological and biomechanical characteristics of glycerol-preserved human sclera. METHODS: A total of 114 paired human sclerae were cleaned and preserved with 98% glycerol under refrigeration at 4 to 8ºC. The samples were divided into a control group with no preservation and 5 groups of 19 sclerae in 7, 15, 30, 90 and 180 days of preservation. Each specimen was submitted to histological examination and tested for traction distensibility functions. RESULTS: Preservation in glycerol did not cause alterations in the histological architecture of the scleral tissue. The mean load required to break the scleral tissue increased according to preservation time as a sigmoid function. A significant increase in mechanical resistance and decrease in distension of scleral tissue occurred after 90 days of preservation. CONCLUSIONS: Scleral preservation in glycerol keeps tissue integrity. The preserved material is less distensible after 90 days. Surgeons who use sclera in ophthalmic procedures should be aware of the mechanical characteristics of glycerol-preserved sclera and take into account tissue preservation time. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492007000600019 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492007000600019 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0004-27492007000600019 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.70 n.6 2007 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209024670171136 |