Ultrasound biomicroscopy in the comparison of the anterior segment morphometry before and after pars plana vitrectomy
Autor(a) principal: | |
---|---|
Data de Publicação: | 2006 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492006000600023 |
Resumo: | PURPOSE: To determine if pars plana vitrectomy induces long-term changes in the anterior segment anatomy by means of ultrasound biomicroscopy. METHODS: A prospective case series study was undertaken of consecutive patients referred to a tertiary eye care centre for pars plana vitrectomy as the only procedure. Twenty eyes of 20 patients undergoing pars plana vitrectomy alone were studied by ultrasound biomicroscopy. Silicone oil or scleral buckle was not used in any of the included cases. The following morphometric parameters were compared before and after 3 months of surgery: anterior chamber depth, angle-opening distance at 500 µm from the scleral spur, trabecular-ciliary process distance, ciliary body thickness at 1, 2 and 3 millimeters from the scleral spur and measurement of the supraciliary space thickness, when fluid was detected. RESULTS: No statistically significant differences were found between the preoperative and the postoperative morphometric parameters. CONCLUSION: Uncomplicated pars plana vitrectomy does not induce any long-term change on anterior segment morphometry. Based on these findings, the normal long-term pattern to be expected after pars plana vitrectomy is the conservation of the preoperative morphometry. |
id |
CBO-2_fcd0b5d0ce938bbb674fe5ee808f004c |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492006000600023 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Ultrasound biomicroscopy in the comparison of the anterior segment morphometry before and after pars plana vitrectomyAnterior eye segment/ultrasonographyUltrasonicsAnatomy, cross-sectional/methodsCiliary body/ultrasonographyVitrectomyMicroscopy/instrumentationPURPOSE: To determine if pars plana vitrectomy induces long-term changes in the anterior segment anatomy by means of ultrasound biomicroscopy. METHODS: A prospective case series study was undertaken of consecutive patients referred to a tertiary eye care centre for pars plana vitrectomy as the only procedure. Twenty eyes of 20 patients undergoing pars plana vitrectomy alone were studied by ultrasound biomicroscopy. Silicone oil or scleral buckle was not used in any of the included cases. The following morphometric parameters were compared before and after 3 months of surgery: anterior chamber depth, angle-opening distance at 500 µm from the scleral spur, trabecular-ciliary process distance, ciliary body thickness at 1, 2 and 3 millimeters from the scleral spur and measurement of the supraciliary space thickness, when fluid was detected. RESULTS: No statistically significant differences were found between the preoperative and the postoperative morphometric parameters. CONCLUSION: Uncomplicated pars plana vitrectomy does not induce any long-term change on anterior segment morphometry. Based on these findings, the normal long-term pattern to be expected after pars plana vitrectomy is the conservation of the preoperative morphometry.Conselho Brasileiro de Oftalmologia2006-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492006000600023Arquivos Brasileiros de Oftalmologia v.69 n.6 2006reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.1590/S0004-27492006000600023info:eu-repo/semantics/openAccessMarigo,Flavio de AndradeZisman,MárcioNehemy,Márcio BittarMarigo,Patrícia Vianna Brandãoeng2007-01-31T00:00:00Zoai:scielo:S0004-27492006000600023Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2007-01-31T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Ultrasound biomicroscopy in the comparison of the anterior segment morphometry before and after pars plana vitrectomy |
title |
Ultrasound biomicroscopy in the comparison of the anterior segment morphometry before and after pars plana vitrectomy |
spellingShingle |
Ultrasound biomicroscopy in the comparison of the anterior segment morphometry before and after pars plana vitrectomy Marigo,Flavio de Andrade Anterior eye segment/ultrasonography Ultrasonics Anatomy, cross-sectional/methods Ciliary body/ultrasonography Vitrectomy Microscopy/instrumentation |
title_short |
Ultrasound biomicroscopy in the comparison of the anterior segment morphometry before and after pars plana vitrectomy |
title_full |
Ultrasound biomicroscopy in the comparison of the anterior segment morphometry before and after pars plana vitrectomy |
title_fullStr |
Ultrasound biomicroscopy in the comparison of the anterior segment morphometry before and after pars plana vitrectomy |
title_full_unstemmed |
Ultrasound biomicroscopy in the comparison of the anterior segment morphometry before and after pars plana vitrectomy |
title_sort |
Ultrasound biomicroscopy in the comparison of the anterior segment morphometry before and after pars plana vitrectomy |
author |
Marigo,Flavio de Andrade |
author_facet |
Marigo,Flavio de Andrade Zisman,Márcio Nehemy,Márcio Bittar Marigo,Patrícia Vianna Brandão |
author_role |
author |
author2 |
Zisman,Márcio Nehemy,Márcio Bittar Marigo,Patrícia Vianna Brandão |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Marigo,Flavio de Andrade Zisman,Márcio Nehemy,Márcio Bittar Marigo,Patrícia Vianna Brandão |
dc.subject.por.fl_str_mv |
Anterior eye segment/ultrasonography Ultrasonics Anatomy, cross-sectional/methods Ciliary body/ultrasonography Vitrectomy Microscopy/instrumentation |
topic |
Anterior eye segment/ultrasonography Ultrasonics Anatomy, cross-sectional/methods Ciliary body/ultrasonography Vitrectomy Microscopy/instrumentation |
description |
PURPOSE: To determine if pars plana vitrectomy induces long-term changes in the anterior segment anatomy by means of ultrasound biomicroscopy. METHODS: A prospective case series study was undertaken of consecutive patients referred to a tertiary eye care centre for pars plana vitrectomy as the only procedure. Twenty eyes of 20 patients undergoing pars plana vitrectomy alone were studied by ultrasound biomicroscopy. Silicone oil or scleral buckle was not used in any of the included cases. The following morphometric parameters were compared before and after 3 months of surgery: anterior chamber depth, angle-opening distance at 500 µm from the scleral spur, trabecular-ciliary process distance, ciliary body thickness at 1, 2 and 3 millimeters from the scleral spur and measurement of the supraciliary space thickness, when fluid was detected. RESULTS: No statistically significant differences were found between the preoperative and the postoperative morphometric parameters. CONCLUSION: Uncomplicated pars plana vitrectomy does not induce any long-term change on anterior segment morphometry. Based on these findings, the normal long-term pattern to be expected after pars plana vitrectomy is the conservation of the preoperative morphometry. |
publishDate |
2006 |
dc.date.none.fl_str_mv |
2006-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492006000600023 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492006000600023 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0004-27492006000600023 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.69 n.6 2006 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209023828164608 |