Shear wave elastography and Doppler ultrasound in kidney transplant recipients

Detalhes bibliográficos
Autor(a) principal: Gonçalves,Luana Marinho
Data de Publicação: 2022
Outros Autores: Forte,Gabriele Carra, Holz,Tiago Garcia, Libermann,Lucas Lobraico, Figueiredo,Carlos Eduardo Poli de, Hochhegger,Bruno
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Radiologia Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842022000100019
Resumo: Abstract Objective: To evaluate the association between shear wave elastography parameters and arterial resistance in kidney transplant recipients. Materials and Methods: This was a prospective cross-sectional study involving consecutive adult kidney transplant recipients. All patients underwent color Doppler to evaluate the resistive index (RI) and ultrasound shear wave elastography for the quantification of renal allograft stiffness. Results: We evaluated 55 patients, of whom 9 (16.4%) had an RI defined as abnormal (≥ 0.79) and 46 (83.6%) had an RI defined as normal (< 0.79). The mean age was higher in the abnormal RI group than in the normal RI group (68.0 ± 8.6 years vs. 42.6 ± 14.1 years; p < 0.001), as was the mean shear wave velocity (2.6 ± 0.4 m/s vs. 2.2 ± 0.4 m/s; p = 0.013). Multivariate analysis identified two independent predictors of arterial resistance: age (OR = 1.169; 95% CI: 1.056 to 1.294; p = 0.003) and shear wave velocity (OR = 17.1; 95% CI: 1.137 to 257.83; p = 0.040). Conclusion: We observed an association between rigidity in the cortex of the transplanted kidney, as evaluated by shear wave elastography, and arterial resistance, as evaluated by color Doppler, in kidney transplant recipients.
id CBR-1_0797943ee2ca135332dcb0e9009299e9
oai_identifier_str oai:scielo:S0100-39842022000100019
network_acronym_str CBR-1
network_name_str Radiologia Brasileira (Online)
repository_id_str
spelling Shear wave elastography and Doppler ultrasound in kidney transplant recipientsKidney transplantationElasticity imaging techniquesUltrasonography, Doppler, colorAbstract Objective: To evaluate the association between shear wave elastography parameters and arterial resistance in kidney transplant recipients. Materials and Methods: This was a prospective cross-sectional study involving consecutive adult kidney transplant recipients. All patients underwent color Doppler to evaluate the resistive index (RI) and ultrasound shear wave elastography for the quantification of renal allograft stiffness. Results: We evaluated 55 patients, of whom 9 (16.4%) had an RI defined as abnormal (≥ 0.79) and 46 (83.6%) had an RI defined as normal (< 0.79). The mean age was higher in the abnormal RI group than in the normal RI group (68.0 ± 8.6 years vs. 42.6 ± 14.1 years; p < 0.001), as was the mean shear wave velocity (2.6 ± 0.4 m/s vs. 2.2 ± 0.4 m/s; p = 0.013). Multivariate analysis identified two independent predictors of arterial resistance: age (OR = 1.169; 95% CI: 1.056 to 1.294; p = 0.003) and shear wave velocity (OR = 17.1; 95% CI: 1.137 to 257.83; p = 0.040). Conclusion: We observed an association between rigidity in the cortex of the transplanted kidney, as evaluated by shear wave elastography, and arterial resistance, as evaluated by color Doppler, in kidney transplant recipients.Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2022-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842022000100019Radiologia Brasileira v.55 n.1 2022reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/0100-3984.2020.0148info:eu-repo/semantics/openAccessGonçalves,Luana MarinhoForte,Gabriele CarraHolz,Tiago GarciaLibermann,Lucas LobraicoFigueiredo,Carlos Eduardo Poli deHochhegger,Brunoeng2022-02-07T00:00:00Zoai:scielo:S0100-39842022000100019Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2022-02-07T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false
dc.title.none.fl_str_mv Shear wave elastography and Doppler ultrasound in kidney transplant recipients
title Shear wave elastography and Doppler ultrasound in kidney transplant recipients
spellingShingle Shear wave elastography and Doppler ultrasound in kidney transplant recipients
Gonçalves,Luana Marinho
Kidney transplantation
Elasticity imaging techniques
Ultrasonography, Doppler, color
title_short Shear wave elastography and Doppler ultrasound in kidney transplant recipients
title_full Shear wave elastography and Doppler ultrasound in kidney transplant recipients
title_fullStr Shear wave elastography and Doppler ultrasound in kidney transplant recipients
title_full_unstemmed Shear wave elastography and Doppler ultrasound in kidney transplant recipients
title_sort Shear wave elastography and Doppler ultrasound in kidney transplant recipients
author Gonçalves,Luana Marinho
author_facet Gonçalves,Luana Marinho
Forte,Gabriele Carra
Holz,Tiago Garcia
Libermann,Lucas Lobraico
Figueiredo,Carlos Eduardo Poli de
Hochhegger,Bruno
author_role author
author2 Forte,Gabriele Carra
Holz,Tiago Garcia
Libermann,Lucas Lobraico
Figueiredo,Carlos Eduardo Poli de
Hochhegger,Bruno
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Gonçalves,Luana Marinho
Forte,Gabriele Carra
Holz,Tiago Garcia
Libermann,Lucas Lobraico
Figueiredo,Carlos Eduardo Poli de
Hochhegger,Bruno
dc.subject.por.fl_str_mv Kidney transplantation
Elasticity imaging techniques
Ultrasonography, Doppler, color
topic Kidney transplantation
Elasticity imaging techniques
Ultrasonography, Doppler, color
description Abstract Objective: To evaluate the association between shear wave elastography parameters and arterial resistance in kidney transplant recipients. Materials and Methods: This was a prospective cross-sectional study involving consecutive adult kidney transplant recipients. All patients underwent color Doppler to evaluate the resistive index (RI) and ultrasound shear wave elastography for the quantification of renal allograft stiffness. Results: We evaluated 55 patients, of whom 9 (16.4%) had an RI defined as abnormal (≥ 0.79) and 46 (83.6%) had an RI defined as normal (< 0.79). The mean age was higher in the abnormal RI group than in the normal RI group (68.0 ± 8.6 years vs. 42.6 ± 14.1 years; p < 0.001), as was the mean shear wave velocity (2.6 ± 0.4 m/s vs. 2.2 ± 0.4 m/s; p = 0.013). Multivariate analysis identified two independent predictors of arterial resistance: age (OR = 1.169; 95% CI: 1.056 to 1.294; p = 0.003) and shear wave velocity (OR = 17.1; 95% CI: 1.137 to 257.83; p = 0.040). Conclusion: We observed an association between rigidity in the cortex of the transplanted kidney, as evaluated by shear wave elastography, and arterial resistance, as evaluated by color Doppler, in kidney transplant recipients.
publishDate 2022
dc.date.none.fl_str_mv 2022-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842022000100019
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842022000100019
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0100-3984.2020.0148
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
dc.source.none.fl_str_mv Radiologia Brasileira v.55 n.1 2022
reponame:Radiologia Brasileira (Online)
instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron:CBR
instname_str Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron_str CBR
institution CBR
reponame_str Radiologia Brasileira (Online)
collection Radiologia Brasileira (Online)
repository.name.fl_str_mv Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
repository.mail.fl_str_mv radiologiabrasileira@cbr.org.br
_version_ 1754208941085032448