Reproducibility of abdominal fat assessment by ultrasound and computed tomography
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Radiologia Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842017000300141 |
Resumo: | Abstract Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. |
id |
CBR-1_0acdb7c5a0856e12bb631afbaec0de25 |
---|---|
oai_identifier_str |
oai:scielo:S0100-39842017000300141 |
network_acronym_str |
CBR-1 |
network_name_str |
Radiologia Brasileira (Online) |
repository_id_str |
|
spelling |
Reproducibility of abdominal fat assessment by ultrasound and computed tomographyAbdominal fatUltrasonographyComputed tomographyRadiologyAbstract Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2017-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842017000300141Radiologia Brasileira v.50 n.3 2017reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/0100-3984.2016.0023info:eu-repo/semantics/openAccessMauad,Fernando MarumChagas-Neto,Francisco AbaetéBenedeti,Augusto César Garcia SaabNogueira-Barbosa,Marcello HenriqueMuglia,Valdair FranciscoCarneiro,Antonio Adilton OliveiraMuller,Enrico MattanaElias Junior,Jorgeeng2017-07-03T00:00:00Zoai:scielo:S0100-39842017000300141Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2017-07-03T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false |
dc.title.none.fl_str_mv |
Reproducibility of abdominal fat assessment by ultrasound and computed tomography |
title |
Reproducibility of abdominal fat assessment by ultrasound and computed tomography |
spellingShingle |
Reproducibility of abdominal fat assessment by ultrasound and computed tomography Mauad,Fernando Marum Abdominal fat Ultrasonography Computed tomography Radiology |
title_short |
Reproducibility of abdominal fat assessment by ultrasound and computed tomography |
title_full |
Reproducibility of abdominal fat assessment by ultrasound and computed tomography |
title_fullStr |
Reproducibility of abdominal fat assessment by ultrasound and computed tomography |
title_full_unstemmed |
Reproducibility of abdominal fat assessment by ultrasound and computed tomography |
title_sort |
Reproducibility of abdominal fat assessment by ultrasound and computed tomography |
author |
Mauad,Fernando Marum |
author_facet |
Mauad,Fernando Marum Chagas-Neto,Francisco Abaeté Benedeti,Augusto César Garcia Saab Nogueira-Barbosa,Marcello Henrique Muglia,Valdair Francisco Carneiro,Antonio Adilton Oliveira Muller,Enrico Mattana Elias Junior,Jorge |
author_role |
author |
author2 |
Chagas-Neto,Francisco Abaeté Benedeti,Augusto César Garcia Saab Nogueira-Barbosa,Marcello Henrique Muglia,Valdair Francisco Carneiro,Antonio Adilton Oliveira Muller,Enrico Mattana Elias Junior,Jorge |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Mauad,Fernando Marum Chagas-Neto,Francisco Abaeté Benedeti,Augusto César Garcia Saab Nogueira-Barbosa,Marcello Henrique Muglia,Valdair Francisco Carneiro,Antonio Adilton Oliveira Muller,Enrico Mattana Elias Junior,Jorge |
dc.subject.por.fl_str_mv |
Abdominal fat Ultrasonography Computed tomography Radiology |
topic |
Abdominal fat Ultrasonography Computed tomography Radiology |
description |
Abstract Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842017000300141 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842017000300141 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0100-3984.2016.0023 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
dc.source.none.fl_str_mv |
Radiologia Brasileira v.50 n.3 2017 reponame:Radiologia Brasileira (Online) instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) instacron:CBR |
instname_str |
Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
instacron_str |
CBR |
institution |
CBR |
reponame_str |
Radiologia Brasileira (Online) |
collection |
Radiologia Brasileira (Online) |
repository.name.fl_str_mv |
Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
repository.mail.fl_str_mv |
radiologiabrasileira@cbr.org.br |
_version_ |
1754208939333910528 |