Reproducibility of abdominal fat assessment by ultrasound and computed tomography

Detalhes bibliográficos
Autor(a) principal: Mauad,Fernando Marum
Data de Publicação: 2017
Outros Autores: Chagas-Neto,Francisco Abaeté, Benedeti,Augusto César Garcia Saab, Nogueira-Barbosa,Marcello Henrique, Muglia,Valdair Francisco, Carneiro,Antonio Adilton Oliveira, Muller,Enrico Mattana, Elias Junior,Jorge
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Radiologia Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842017000300141
Resumo: Abstract Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.
id CBR-1_0acdb7c5a0856e12bb631afbaec0de25
oai_identifier_str oai:scielo:S0100-39842017000300141
network_acronym_str CBR-1
network_name_str Radiologia Brasileira (Online)
repository_id_str
spelling Reproducibility of abdominal fat assessment by ultrasound and computed tomographyAbdominal fatUltrasonographyComputed tomographyRadiologyAbstract Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2017-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842017000300141Radiologia Brasileira v.50 n.3 2017reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/0100-3984.2016.0023info:eu-repo/semantics/openAccessMauad,Fernando MarumChagas-Neto,Francisco AbaetéBenedeti,Augusto César Garcia SaabNogueira-Barbosa,Marcello HenriqueMuglia,Valdair FranciscoCarneiro,Antonio Adilton OliveiraMuller,Enrico MattanaElias Junior,Jorgeeng2017-07-03T00:00:00Zoai:scielo:S0100-39842017000300141Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2017-07-03T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false
dc.title.none.fl_str_mv Reproducibility of abdominal fat assessment by ultrasound and computed tomography
title Reproducibility of abdominal fat assessment by ultrasound and computed tomography
spellingShingle Reproducibility of abdominal fat assessment by ultrasound and computed tomography
Mauad,Fernando Marum
Abdominal fat
Ultrasonography
Computed tomography
Radiology
title_short Reproducibility of abdominal fat assessment by ultrasound and computed tomography
title_full Reproducibility of abdominal fat assessment by ultrasound and computed tomography
title_fullStr Reproducibility of abdominal fat assessment by ultrasound and computed tomography
title_full_unstemmed Reproducibility of abdominal fat assessment by ultrasound and computed tomography
title_sort Reproducibility of abdominal fat assessment by ultrasound and computed tomography
author Mauad,Fernando Marum
author_facet Mauad,Fernando Marum
Chagas-Neto,Francisco Abaeté
Benedeti,Augusto César Garcia Saab
Nogueira-Barbosa,Marcello Henrique
Muglia,Valdair Francisco
Carneiro,Antonio Adilton Oliveira
Muller,Enrico Mattana
Elias Junior,Jorge
author_role author
author2 Chagas-Neto,Francisco Abaeté
Benedeti,Augusto César Garcia Saab
Nogueira-Barbosa,Marcello Henrique
Muglia,Valdair Francisco
Carneiro,Antonio Adilton Oliveira
Muller,Enrico Mattana
Elias Junior,Jorge
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Mauad,Fernando Marum
Chagas-Neto,Francisco Abaeté
Benedeti,Augusto César Garcia Saab
Nogueira-Barbosa,Marcello Henrique
Muglia,Valdair Francisco
Carneiro,Antonio Adilton Oliveira
Muller,Enrico Mattana
Elias Junior,Jorge
dc.subject.por.fl_str_mv Abdominal fat
Ultrasonography
Computed tomography
Radiology
topic Abdominal fat
Ultrasonography
Computed tomography
Radiology
description Abstract Objective: To test the accuracy and reproducibility of ultrasound and computed tomography (CT) for the quantification of abdominal fat in correlation with the anthropometric, clinical, and biochemical assessments. Materials and Methods: Using ultrasound and CT, we determined the thickness of subcutaneous and intra-abdominal fat in 101 subjects-of whom 39 (38.6%) were men and 62 (61.4%) were women-with a mean age of 66.3 years (60-80 years). The ultrasound data were correlated with the anthropometric, clinical, and biochemical parameters, as well as with the areas measured by abdominal CT. Results: Intra-abdominal thickness was the variable for which the correlation with the areas of abdominal fat was strongest (i.e., the correlation coefficient was highest). We also tested the reproducibility of ultrasound and CT for the assessment of abdominal fat and found that CT measurements of abdominal fat showed greater reproducibility, having higher intraobserver and interobserver reliability than had the ultrasound measurements. There was a significant correlation between ultrasound and CT, with a correlation coefficient of 0.71. Conclusion: In the assessment of abdominal fat, the intraobserver and interobserver reliability were greater for CT than for ultrasound, although both methods showed high accuracy and good reproducibility.
publishDate 2017
dc.date.none.fl_str_mv 2017-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842017000300141
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842017000300141
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0100-3984.2016.0023
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
dc.source.none.fl_str_mv Radiologia Brasileira v.50 n.3 2017
reponame:Radiologia Brasileira (Online)
instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron:CBR
instname_str Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron_str CBR
institution CBR
reponame_str Radiologia Brasileira (Online)
collection Radiologia Brasileira (Online)
repository.name.fl_str_mv Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
repository.mail.fl_str_mv radiologiabrasileira@cbr.org.br
_version_ 1754208939333910528