Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Radiologia Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000200006 |
Resumo: | Abstract Objective: To propose a protocol for pulmonary angiography using 64-slice multidetector computed tomography (64-MDCT) with 50 mL of iodinated contrast material, in an unselected patient population, as well as to evaluate vascular enhancement and image quality. Materials and Methods: We evaluated 29 patients (22-86 years of age). The body mass index ranged from 19.0 kg/m2 to 41.8 kg/m2. Patients underwent pulmonary CT angiography in a 64-MDCT scanner, receiving 50 mL of iodinated contrast material via venous access at a rate of 4.5 mL/s. Bolus tracking was applied in the superior vena cava. Two experienced radiologists assessed image quality and vascular enhancement. Results: The mean density was 382 Hounsfield units (HU) for the pulmonary trunk; 379 and 377 HU for the right and left main pulmonary arteries, respectively; and 346 and 364 HU for the right and left inferior pulmonary arteries, respectively. In all patients, subsegmental arteries were analyzed. There were streak artifacts from contrast material in the superior vena cava in all patients. However, those artifacts did not impair the image analysis. Conclusion: Our findings suggest that pulmonary angiography using 64-MDCT with 50 mL of iodinated contrast can produce high quality images in unselected patient populations. |
id |
CBR-1_0aff55f0506e863dae7c95df25c64eed |
---|---|
oai_identifier_str |
oai:scielo:S0100-39842016000200006 |
network_acronym_str |
CBR-1 |
network_name_str |
Radiologia Brasileira (Online) |
repository_id_str |
|
spelling |
Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocolTomography, X-ray computedContrast mediaAngiographyPulmonary embolismAbstract Objective: To propose a protocol for pulmonary angiography using 64-slice multidetector computed tomography (64-MDCT) with 50 mL of iodinated contrast material, in an unselected patient population, as well as to evaluate vascular enhancement and image quality. Materials and Methods: We evaluated 29 patients (22-86 years of age). The body mass index ranged from 19.0 kg/m2 to 41.8 kg/m2. Patients underwent pulmonary CT angiography in a 64-MDCT scanner, receiving 50 mL of iodinated contrast material via venous access at a rate of 4.5 mL/s. Bolus tracking was applied in the superior vena cava. Two experienced radiologists assessed image quality and vascular enhancement. Results: The mean density was 382 Hounsfield units (HU) for the pulmonary trunk; 379 and 377 HU for the right and left main pulmonary arteries, respectively; and 346 and 364 HU for the right and left inferior pulmonary arteries, respectively. In all patients, subsegmental arteries were analyzed. There were streak artifacts from contrast material in the superior vena cava in all patients. However, those artifacts did not impair the image analysis. Conclusion: Our findings suggest that pulmonary angiography using 64-MDCT with 50 mL of iodinated contrast can produce high quality images in unselected patient populations.Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2016-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000200006Radiologia Brasileira v.49 n.2 2016reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/0100-3984.2014.0115info:eu-repo/semantics/openAccessTrad,Henrique SimãoBoasquevisque,Gustavo SantosGiacometti,Tiago RangonTrad,Catherine YangZoghbi Neto,Orlando SalomãoTrad,Clovis Simãoeng2016-05-03T00:00:00Zoai:scielo:S0100-39842016000200006Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2016-05-03T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false |
dc.title.none.fl_str_mv |
Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol |
title |
Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol |
spellingShingle |
Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol Trad,Henrique Simão Tomography, X-ray computed Contrast media Angiography Pulmonary embolism |
title_short |
Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol |
title_full |
Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol |
title_fullStr |
Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol |
title_full_unstemmed |
Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol |
title_sort |
Pulmonary 64-MDCT angiography with 50 mL of iodinated contrast material in an unselected patient population: a feasible protocol |
author |
Trad,Henrique Simão |
author_facet |
Trad,Henrique Simão Boasquevisque,Gustavo Santos Giacometti,Tiago Rangon Trad,Catherine Yang Zoghbi Neto,Orlando Salomão Trad,Clovis Simão |
author_role |
author |
author2 |
Boasquevisque,Gustavo Santos Giacometti,Tiago Rangon Trad,Catherine Yang Zoghbi Neto,Orlando Salomão Trad,Clovis Simão |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Trad,Henrique Simão Boasquevisque,Gustavo Santos Giacometti,Tiago Rangon Trad,Catherine Yang Zoghbi Neto,Orlando Salomão Trad,Clovis Simão |
dc.subject.por.fl_str_mv |
Tomography, X-ray computed Contrast media Angiography Pulmonary embolism |
topic |
Tomography, X-ray computed Contrast media Angiography Pulmonary embolism |
description |
Abstract Objective: To propose a protocol for pulmonary angiography using 64-slice multidetector computed tomography (64-MDCT) with 50 mL of iodinated contrast material, in an unselected patient population, as well as to evaluate vascular enhancement and image quality. Materials and Methods: We evaluated 29 patients (22-86 years of age). The body mass index ranged from 19.0 kg/m2 to 41.8 kg/m2. Patients underwent pulmonary CT angiography in a 64-MDCT scanner, receiving 50 mL of iodinated contrast material via venous access at a rate of 4.5 mL/s. Bolus tracking was applied in the superior vena cava. Two experienced radiologists assessed image quality and vascular enhancement. Results: The mean density was 382 Hounsfield units (HU) for the pulmonary trunk; 379 and 377 HU for the right and left main pulmonary arteries, respectively; and 346 and 364 HU for the right and left inferior pulmonary arteries, respectively. In all patients, subsegmental arteries were analyzed. There were streak artifacts from contrast material in the superior vena cava in all patients. However, those artifacts did not impair the image analysis. Conclusion: Our findings suggest that pulmonary angiography using 64-MDCT with 50 mL of iodinated contrast can produce high quality images in unselected patient populations. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000200006 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000200006 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0100-3984.2014.0115 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
dc.source.none.fl_str_mv |
Radiologia Brasileira v.49 n.2 2016 reponame:Radiologia Brasileira (Online) instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) instacron:CBR |
instname_str |
Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
instacron_str |
CBR |
institution |
CBR |
reponame_str |
Radiologia Brasileira (Online) |
collection |
Radiologia Brasileira (Online) |
repository.name.fl_str_mv |
Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
repository.mail.fl_str_mv |
radiologiabrasileira@cbr.org.br |
_version_ |
1754208938955374592 |