Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Radiologia Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000300007 |
Resumo: | Abstract Objective: To identify a contrast material that could be used as a dummy marker for magnetic resonance imaging. Materials and Methods: Magnetic resonance images were acquired with six different catheter-filling materials-water, glucose 50%, saline, olive oil, glycerin, and copper sulfate (CuSO4) water solution (2.08 g/L)-inserted into compatible computed tomography/magnetic resonance imaging ring applicators placed in a phantom made of gelatin and CuSO4. The best contrast media were tested in four patients with the applicators in place. Results: In T2-weighted sequences, the best contrast was achieved with the CuSO4-filled catheters, followed by saline- and glycerin-filled catheters, which presented poor visualization. In addition (also in T2-weighted sequences), CuSO4 presented better contrast when tested in the phantom than when tested in the patients, in which it provided some contrast but with poor identification of the first dwell position, mainly in the ring. Conclusion: We found CuSO4 to be the best solution for visualization of the applicator channels, mainly in T2-weighted images in vitro, although the materials tested presented low signal intensity in the images obtained in vivo, as well as poor precision in determining the first dwell position. |
id |
CBR-1_28a6d1c8b97471a53222b6e53102fb7b |
---|---|
oai_identifier_str |
oai:scielo:S0100-39842016000300007 |
network_acronym_str |
CBR-1 |
network_name_str |
Radiologia Brasileira (Online) |
repository_id_str |
|
spelling |
Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignanciesImaging, three-dimensionalBrachytherapy/methodsDiagnostic techniques, obstetrical and gynecologicalMagnetic resonance imaging/methodsContrast mediaAbstract Objective: To identify a contrast material that could be used as a dummy marker for magnetic resonance imaging. Materials and Methods: Magnetic resonance images were acquired with six different catheter-filling materials-water, glucose 50%, saline, olive oil, glycerin, and copper sulfate (CuSO4) water solution (2.08 g/L)-inserted into compatible computed tomography/magnetic resonance imaging ring applicators placed in a phantom made of gelatin and CuSO4. The best contrast media were tested in four patients with the applicators in place. Results: In T2-weighted sequences, the best contrast was achieved with the CuSO4-filled catheters, followed by saline- and glycerin-filled catheters, which presented poor visualization. In addition (also in T2-weighted sequences), CuSO4 presented better contrast when tested in the phantom than when tested in the patients, in which it provided some contrast but with poor identification of the first dwell position, mainly in the ring. Conclusion: We found CuSO4 to be the best solution for visualization of the applicator channels, mainly in T2-weighted images in vitro, although the materials tested presented low signal intensity in the images obtained in vivo, as well as poor precision in determining the first dwell position.Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2016-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000300007Radiologia Brasileira v.49 n.3 2016reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/0100-3984.2015.0004info:eu-repo/semantics/openAccessSales,Camila PessoaCarvalho,Heloisa de AndradeTaverna,Khallil ChaimPastorello,Bruno FracciniRubo,Rodrigo AugustoBorgonovi,Arthur FelipeStuart,Silvia RadwanskiRodrigues,Laura Nataleng2016-07-12T00:00:00Zoai:scielo:S0100-39842016000300007Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2016-07-12T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false |
dc.title.none.fl_str_mv |
Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies |
title |
Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies |
spellingShingle |
Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies Sales,Camila Pessoa Imaging, three-dimensional Brachytherapy/methods Diagnostic techniques, obstetrical and gynecological Magnetic resonance imaging/methods Contrast media |
title_short |
Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies |
title_full |
Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies |
title_fullStr |
Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies |
title_full_unstemmed |
Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies |
title_sort |
Evaluation of different magnetic resonance imaging contrast materials to be used as dummy markers in image-guided brachytherapy for gynecologic malignancies |
author |
Sales,Camila Pessoa |
author_facet |
Sales,Camila Pessoa Carvalho,Heloisa de Andrade Taverna,Khallil Chaim Pastorello,Bruno Fraccini Rubo,Rodrigo Augusto Borgonovi,Arthur Felipe Stuart,Silvia Radwanski Rodrigues,Laura Natal |
author_role |
author |
author2 |
Carvalho,Heloisa de Andrade Taverna,Khallil Chaim Pastorello,Bruno Fraccini Rubo,Rodrigo Augusto Borgonovi,Arthur Felipe Stuart,Silvia Radwanski Rodrigues,Laura Natal |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Sales,Camila Pessoa Carvalho,Heloisa de Andrade Taverna,Khallil Chaim Pastorello,Bruno Fraccini Rubo,Rodrigo Augusto Borgonovi,Arthur Felipe Stuart,Silvia Radwanski Rodrigues,Laura Natal |
dc.subject.por.fl_str_mv |
Imaging, three-dimensional Brachytherapy/methods Diagnostic techniques, obstetrical and gynecological Magnetic resonance imaging/methods Contrast media |
topic |
Imaging, three-dimensional Brachytherapy/methods Diagnostic techniques, obstetrical and gynecological Magnetic resonance imaging/methods Contrast media |
description |
Abstract Objective: To identify a contrast material that could be used as a dummy marker for magnetic resonance imaging. Materials and Methods: Magnetic resonance images were acquired with six different catheter-filling materials-water, glucose 50%, saline, olive oil, glycerin, and copper sulfate (CuSO4) water solution (2.08 g/L)-inserted into compatible computed tomography/magnetic resonance imaging ring applicators placed in a phantom made of gelatin and CuSO4. The best contrast media were tested in four patients with the applicators in place. Results: In T2-weighted sequences, the best contrast was achieved with the CuSO4-filled catheters, followed by saline- and glycerin-filled catheters, which presented poor visualization. In addition (also in T2-weighted sequences), CuSO4 presented better contrast when tested in the phantom than when tested in the patients, in which it provided some contrast but with poor identification of the first dwell position, mainly in the ring. Conclusion: We found CuSO4 to be the best solution for visualization of the applicator channels, mainly in T2-weighted images in vitro, although the materials tested presented low signal intensity in the images obtained in vivo, as well as poor precision in determining the first dwell position. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000300007 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000300007 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0100-3984.2015.0004 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
dc.source.none.fl_str_mv |
Radiologia Brasileira v.49 n.3 2016 reponame:Radiologia Brasileira (Online) instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) instacron:CBR |
instname_str |
Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
instacron_str |
CBR |
institution |
CBR |
reponame_str |
Radiologia Brasileira (Online) |
collection |
Radiologia Brasileira (Online) |
repository.name.fl_str_mv |
Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
repository.mail.fl_str_mv |
radiologiabrasileira@cbr.org.br |
_version_ |
1754208938978443264 |