Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities

Detalhes bibliográficos
Autor(a) principal: Valadares,Agnes Araujo
Data de Publicação: 2015
Outros Autores: Duarte,Paulo Schiavom, Woellner,Eduardo Bechtloff, Coura-Filho,George Barberio, Sapienza,Marcelo Tatit, Buchpiguel,Carlos Alberto
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Radiologia Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842015000100007
Resumo: Objective: To analyze standardized uptake values (SUVs) using three different tube current intensities for attenuation correction on 18FNaF PET/CT scans. Materials and Methods: A total of 254 18F-NaF PET/CT studies were analyzed using 10, 20 and 30 mAs. The SUVs were calculated in volumes of interest (VOIs) drawn on three skeletal regions, namely, right proximal humeral diaphysis (RH), right proximal femoral diaphysis (RF), and first lumbar vertebra (LV1) in a total of 712 VOIs. The analyses covered 675 regions classified as normal (236 RH, 232 RF, and 207 LV1). Results: Mean SUV for each skeletal region was 3.8, 5.4 and 14.4 for RH, RF, and LV1, respectively. As the studies were grouped according to mAs value, the mean SUV values were 3.8, 3.9 and 3.7 for 10, 20 and 30 mAs, respectively, in the RH region; 5.4, 5.5 and 5.4 for 10, 20 and 30 mAs, respectively, in the RF region; 13.8, 14.9 and 14.5 for 10, 20 and 30 mAs, respectively, in the LV1 region. Conclusion: The three tube current values yielded similar results for SUV calculation.
id CBR-1_6cf27745f76cdfde91cba78d11acf2a5
oai_identifier_str oai:scielo:S0100-39842015000100007
network_acronym_str CBR-1
network_name_str Radiologia Brasileira (Online)
repository_id_str
spelling Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities18F-NaF PET/CTSUVTube currentmAs18F-NaF PET/CTSUVCorrente de tubomAs Objective: To analyze standardized uptake values (SUVs) using three different tube current intensities for attenuation correction on 18FNaF PET/CT scans. Materials and Methods: A total of 254 18F-NaF PET/CT studies were analyzed using 10, 20 and 30 mAs. The SUVs were calculated in volumes of interest (VOIs) drawn on three skeletal regions, namely, right proximal humeral diaphysis (RH), right proximal femoral diaphysis (RF), and first lumbar vertebra (LV1) in a total of 712 VOIs. The analyses covered 675 regions classified as normal (236 RH, 232 RF, and 207 LV1). Results: Mean SUV for each skeletal region was 3.8, 5.4 and 14.4 for RH, RF, and LV1, respectively. As the studies were grouped according to mAs value, the mean SUV values were 3.8, 3.9 and 3.7 for 10, 20 and 30 mAs, respectively, in the RH region; 5.4, 5.5 and 5.4 for 10, 20 and 30 mAs, respectively, in the RF region; 13.8, 14.9 and 14.5 for 10, 20 and 30 mAs, respectively, in the LV1 region. Conclusion: The three tube current values yielded similar results for SUV calculation. Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2015-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842015000100007Radiologia Brasileira v.48 n.1 2015reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/0100-3984.2014.0034info:eu-repo/semantics/openAccessValadares,Agnes AraujoDuarte,Paulo SchiavomWoellner,Eduardo BechtloffCoura-Filho,George BarberioSapienza,Marcelo TatitBuchpiguel,Carlos Albertoeng2015-04-14T00:00:00Zoai:scielo:S0100-39842015000100007Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2015-04-14T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false
dc.title.none.fl_str_mv Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities
title Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities
spellingShingle Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities
Valadares,Agnes Araujo
18F-NaF PET/CT
SUV
Tube current
mAs
18F-NaF PET/CT
SUV
Corrente de tubo
mAs
title_short Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities
title_full Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities
title_fullStr Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities
title_full_unstemmed Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities
title_sort Comparison of standardized uptake values measured on 18F-NaF PET/CT scans using three different tube current intensities
author Valadares,Agnes Araujo
author_facet Valadares,Agnes Araujo
Duarte,Paulo Schiavom
Woellner,Eduardo Bechtloff
Coura-Filho,George Barberio
Sapienza,Marcelo Tatit
Buchpiguel,Carlos Alberto
author_role author
author2 Duarte,Paulo Schiavom
Woellner,Eduardo Bechtloff
Coura-Filho,George Barberio
Sapienza,Marcelo Tatit
Buchpiguel,Carlos Alberto
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Valadares,Agnes Araujo
Duarte,Paulo Schiavom
Woellner,Eduardo Bechtloff
Coura-Filho,George Barberio
Sapienza,Marcelo Tatit
Buchpiguel,Carlos Alberto
dc.subject.por.fl_str_mv 18F-NaF PET/CT
SUV
Tube current
mAs
18F-NaF PET/CT
SUV
Corrente de tubo
mAs
topic 18F-NaF PET/CT
SUV
Tube current
mAs
18F-NaF PET/CT
SUV
Corrente de tubo
mAs
description Objective: To analyze standardized uptake values (SUVs) using three different tube current intensities for attenuation correction on 18FNaF PET/CT scans. Materials and Methods: A total of 254 18F-NaF PET/CT studies were analyzed using 10, 20 and 30 mAs. The SUVs were calculated in volumes of interest (VOIs) drawn on three skeletal regions, namely, right proximal humeral diaphysis (RH), right proximal femoral diaphysis (RF), and first lumbar vertebra (LV1) in a total of 712 VOIs. The analyses covered 675 regions classified as normal (236 RH, 232 RF, and 207 LV1). Results: Mean SUV for each skeletal region was 3.8, 5.4 and 14.4 for RH, RF, and LV1, respectively. As the studies were grouped according to mAs value, the mean SUV values were 3.8, 3.9 and 3.7 for 10, 20 and 30 mAs, respectively, in the RH region; 5.4, 5.5 and 5.4 for 10, 20 and 30 mAs, respectively, in the RF region; 13.8, 14.9 and 14.5 for 10, 20 and 30 mAs, respectively, in the LV1 region. Conclusion: The three tube current values yielded similar results for SUV calculation.
publishDate 2015
dc.date.none.fl_str_mv 2015-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842015000100007
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842015000100007
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0100-3984.2014.0034
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
dc.source.none.fl_str_mv Radiologia Brasileira v.48 n.1 2015
reponame:Radiologia Brasileira (Online)
instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron:CBR
instname_str Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron_str CBR
institution CBR
reponame_str Radiologia Brasileira (Online)
collection Radiologia Brasileira (Online)
repository.name.fl_str_mv Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
repository.mail.fl_str_mv radiologiabrasileira@cbr.org.br
_version_ 1754208938855759872