Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Radiologia Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842013000400221 |
Resumo: | Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones. |
id |
CBR-1_a179a3e484cf659250f5b14ef9a15cc7 |
---|---|
oai_identifier_str |
oai:scielo:S0100-39842013000400221 |
network_acronym_str |
CBR-1 |
network_name_str |
Radiologia Brasileira (Online) |
repository_id_str |
|
spelling |
Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumorsBrachytherapyGlioblastoma multiformeDosimetryBNCTMCNP Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones. Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2013-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842013000400221Radiologia Brasileira v.46 n.4 2013reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/S0100-39842013000400008info:eu-repo/semantics/openAccessBrandão,Sâmia de FreitasCampos,Tarcísio Passos Ribeiro deeng2015-09-03T00:00:00Zoai:scielo:S0100-39842013000400221Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2015-09-03T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false |
dc.title.none.fl_str_mv |
Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors |
title |
Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors |
spellingShingle |
Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors Brandão,Sâmia de Freitas Brachytherapy Glioblastoma multiforme Dosimetry BNCT MCNP |
title_short |
Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors |
title_full |
Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors |
title_fullStr |
Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors |
title_full_unstemmed |
Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors |
title_sort |
Comparative dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for brain tumors |
author |
Brandão,Sâmia de Freitas |
author_facet |
Brandão,Sâmia de Freitas Campos,Tarcísio Passos Ribeiro de |
author_role |
author |
author2 |
Campos,Tarcísio Passos Ribeiro de |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Brandão,Sâmia de Freitas Campos,Tarcísio Passos Ribeiro de |
dc.subject.por.fl_str_mv |
Brachytherapy Glioblastoma multiforme Dosimetry BNCT MCNP |
topic |
Brachytherapy Glioblastoma multiforme Dosimetry BNCT MCNP |
description |
Objective Comparative analysis of dosimetry in intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT for treatment of brain tumors. Materials and Methods Simulations of intracavitary balloon catheter brachytherapy with I-125 and in Cf-252 brachytherapy combined with BNCT were performed with the MCNP5 code, modeling the treatment of a brain tumor on a voxel computational phantom representing a human head. Absorbed dose rates were converted into biologically weighted dose rates. Results Intracavitary balloon catheter brachytherapy with I-125 produced biologically weighted mean dose rates of 3.2E-11, 1.3E-10, 1.9E-11 and 6.9E-13 RBE.Gy.h-1.p-1.s, respectively, on the healthy tissue, on the balloon periphery and on the I 1 and I 2 tumor infiltration zones. On the other hand, Cf-252 brachytherapy combined with BNCT produced a biologically weighted mean dose rate of 5.2E-09, 2.3E-07, 8.7E-09 and 2.4E-09 RBE.Gy.h-1.p-1.s, respectively on the healthy tissue, on the target tumor and on the I 1 and I 2 infiltration zones. Conclusion Cf-252 brachytherapy combined with BNCT delivered a selective irradiation to the target tumor and to infiltration zones, while intracavitary balloon catheter brachytherapy with I-125 delivered negligible doses on the tumor infiltration zones. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-08-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842013000400221 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842013000400221 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0100-39842013000400008 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
dc.source.none.fl_str_mv |
Radiologia Brasileira v.46 n.4 2013 reponame:Radiologia Brasileira (Online) instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) instacron:CBR |
instname_str |
Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
instacron_str |
CBR |
institution |
CBR |
reponame_str |
Radiologia Brasileira (Online) |
collection |
Radiologia Brasileira (Online) |
repository.name.fl_str_mv |
Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
repository.mail.fl_str_mv |
radiologiabrasileira@cbr.org.br |
_version_ |
1754208938459398144 |