Comparison of power Doppler and thermography for the selection of thyroid nodules in which fine-needle aspiration biopsy is indicated
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Radiologia Brasileira (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000500009 |
Resumo: | Abstract Objective: To compare two methods-power Doppler and thermography-for the analysis of nodule vascularization and subsequent selection of nodules to be biopsied. Materials and Methods: A total of 510 subjects with thyroid nodules were analyzed by power Doppler and submitted to fine-needle aspiration biopsy (FNAB). Thirty-seven patients were submitted to nodule excision (29 due to carcinoma or suspected carcinoma and 8 by patient choice). Among those patients, power Doppler had raised the suspicion of malignancy in 39 lesions, compared with 48 for FNAB. Another group, comprising 110 patients, underwent thermography, which raised the suspicion of malignancy in 124 thyroid nodules, as did FNAB. Malignant nodules were excised in all 110 of those patients (95 underwent nodulectomy and 15 underwent thyroidectomy), malignancy being confirmed by intraoperative examination of frozen biopsy samples. Results: In relation to the FNAB findings, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of power Doppler were 95.16%, 23.52%, 96.22%, 16.70%, and 89.51%, respectively, compared with 100%, 58.06%, 87.73%, 100%, and 89.51%, respectively, for thermography. Conclusion: Thermography was more precise than was power Doppler for the selection of thyroid nodules to be biopsied. |
id |
CBR-1_cc872617a752527142a31da4f1d91a90 |
---|---|
oai_identifier_str |
oai:scielo:S0100-39842016000500009 |
network_acronym_str |
CBR-1 |
network_name_str |
Radiologia Brasileira (Online) |
repository_id_str |
|
spelling |
Comparison of power Doppler and thermography for the selection of thyroid nodules in which fine-needle aspiration biopsy is indicatedThyroid glandThyroid nodule/blood supplyUltrasonography, DopplerThermographyAbstract Objective: To compare two methods-power Doppler and thermography-for the analysis of nodule vascularization and subsequent selection of nodules to be biopsied. Materials and Methods: A total of 510 subjects with thyroid nodules were analyzed by power Doppler and submitted to fine-needle aspiration biopsy (FNAB). Thirty-seven patients were submitted to nodule excision (29 due to carcinoma or suspected carcinoma and 8 by patient choice). Among those patients, power Doppler had raised the suspicion of malignancy in 39 lesions, compared with 48 for FNAB. Another group, comprising 110 patients, underwent thermography, which raised the suspicion of malignancy in 124 thyroid nodules, as did FNAB. Malignant nodules were excised in all 110 of those patients (95 underwent nodulectomy and 15 underwent thyroidectomy), malignancy being confirmed by intraoperative examination of frozen biopsy samples. Results: In relation to the FNAB findings, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of power Doppler were 95.16%, 23.52%, 96.22%, 16.70%, and 89.51%, respectively, compared with 100%, 58.06%, 87.73%, 100%, and 89.51%, respectively, for thermography. Conclusion: Thermography was more precise than was power Doppler for the selection of thyroid nodules to be biopsied.Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2016-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000500009Radiologia Brasileira v.49 n.5 2016reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/0100-3984.2014.0111info:eu-repo/semantics/openAccessAlves,Maria Lucia D'ArboGabarra,Manoel Henrique Cintraeng2016-11-07T00:00:00Zoai:scielo:S0100-39842016000500009Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2016-11-07T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false |
dc.title.none.fl_str_mv |
Comparison of power Doppler and thermography for the selection of thyroid nodules in which fine-needle aspiration biopsy is indicated |
title |
Comparison of power Doppler and thermography for the selection of thyroid nodules in which fine-needle aspiration biopsy is indicated |
spellingShingle |
Comparison of power Doppler and thermography for the selection of thyroid nodules in which fine-needle aspiration biopsy is indicated Alves,Maria Lucia D'Arbo Thyroid gland Thyroid nodule/blood supply Ultrasonography, Doppler Thermography |
title_short |
Comparison of power Doppler and thermography for the selection of thyroid nodules in which fine-needle aspiration biopsy is indicated |
title_full |
Comparison of power Doppler and thermography for the selection of thyroid nodules in which fine-needle aspiration biopsy is indicated |
title_fullStr |
Comparison of power Doppler and thermography for the selection of thyroid nodules in which fine-needle aspiration biopsy is indicated |
title_full_unstemmed |
Comparison of power Doppler and thermography for the selection of thyroid nodules in which fine-needle aspiration biopsy is indicated |
title_sort |
Comparison of power Doppler and thermography for the selection of thyroid nodules in which fine-needle aspiration biopsy is indicated |
author |
Alves,Maria Lucia D'Arbo |
author_facet |
Alves,Maria Lucia D'Arbo Gabarra,Manoel Henrique Cintra |
author_role |
author |
author2 |
Gabarra,Manoel Henrique Cintra |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Alves,Maria Lucia D'Arbo Gabarra,Manoel Henrique Cintra |
dc.subject.por.fl_str_mv |
Thyroid gland Thyroid nodule/blood supply Ultrasonography, Doppler Thermography |
topic |
Thyroid gland Thyroid nodule/blood supply Ultrasonography, Doppler Thermography |
description |
Abstract Objective: To compare two methods-power Doppler and thermography-for the analysis of nodule vascularization and subsequent selection of nodules to be biopsied. Materials and Methods: A total of 510 subjects with thyroid nodules were analyzed by power Doppler and submitted to fine-needle aspiration biopsy (FNAB). Thirty-seven patients were submitted to nodule excision (29 due to carcinoma or suspected carcinoma and 8 by patient choice). Among those patients, power Doppler had raised the suspicion of malignancy in 39 lesions, compared with 48 for FNAB. Another group, comprising 110 patients, underwent thermography, which raised the suspicion of malignancy in 124 thyroid nodules, as did FNAB. Malignant nodules were excised in all 110 of those patients (95 underwent nodulectomy and 15 underwent thyroidectomy), malignancy being confirmed by intraoperative examination of frozen biopsy samples. Results: In relation to the FNAB findings, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of power Doppler were 95.16%, 23.52%, 96.22%, 16.70%, and 89.51%, respectively, compared with 100%, 58.06%, 87.73%, 100%, and 89.51%, respectively, for thermography. Conclusion: Thermography was more precise than was power Doppler for the selection of thyroid nodules to be biopsied. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000500009 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842016000500009 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/0100-3984.2014.0111 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
publisher.none.fl_str_mv |
Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem |
dc.source.none.fl_str_mv |
Radiologia Brasileira v.49 n.5 2016 reponame:Radiologia Brasileira (Online) instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) instacron:CBR |
instname_str |
Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
instacron_str |
CBR |
institution |
CBR |
reponame_str |
Radiologia Brasileira (Online) |
collection |
Radiologia Brasileira (Online) |
repository.name.fl_str_mv |
Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR) |
repository.mail.fl_str_mv |
radiologiabrasileira@cbr.org.br |
_version_ |
1754208939270995968 |