Complete internal audit of a mammography service in a reference institution for breast imaging

Detalhes bibliográficos
Autor(a) principal: Badan,Gustavo Machado
Data de Publicação: 2014
Outros Autores: Roveda Júnior,Décio, Ferreira,Carlos Alberto Pecci, Junior,Ozeas Alves de Noronha
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Radiologia Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842014000200007
Resumo: Objective Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS®, in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Materials and Methods Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. Results The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. Conclusion The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.
id CBR-1_ffbbc4e64ad2cc2b87726cba8346361c
oai_identifier_str oai:scielo:S0100-39842014000200007
network_acronym_str CBR-1
network_name_str Radiologia Brasileira (Online)
repository_id_str
spelling Complete internal audit of a mammography service in a reference institution for breast imagingBreast cancerMammographic screeningBI-RADSAudit of mammography servicePercutaneous biopsyPositive predictive value Objective Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS®, in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Materials and Methods Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. Results The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. Conclusion The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates. Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2014-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842014000200007Radiologia Brasileira v.47 n.2 2014reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/S0100-39842014000200007info:eu-repo/semantics/openAccessBadan,Gustavo MachadoRoveda Júnior,DécioFerreira,Carlos Alberto PecciJunior,Ozeas Alves de Noronhaeng2015-08-31T00:00:00Zoai:scielo:S0100-39842014000200007Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2015-08-31T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false
dc.title.none.fl_str_mv Complete internal audit of a mammography service in a reference institution for breast imaging
title Complete internal audit of a mammography service in a reference institution for breast imaging
spellingShingle Complete internal audit of a mammography service in a reference institution for breast imaging
Badan,Gustavo Machado
Breast cancer
Mammographic screening
BI-RADS
Audit of mammography service
Percutaneous biopsy
Positive predictive value
title_short Complete internal audit of a mammography service in a reference institution for breast imaging
title_full Complete internal audit of a mammography service in a reference institution for breast imaging
title_fullStr Complete internal audit of a mammography service in a reference institution for breast imaging
title_full_unstemmed Complete internal audit of a mammography service in a reference institution for breast imaging
title_sort Complete internal audit of a mammography service in a reference institution for breast imaging
author Badan,Gustavo Machado
author_facet Badan,Gustavo Machado
Roveda Júnior,Décio
Ferreira,Carlos Alberto Pecci
Junior,Ozeas Alves de Noronha
author_role author
author2 Roveda Júnior,Décio
Ferreira,Carlos Alberto Pecci
Junior,Ozeas Alves de Noronha
author2_role author
author
author
dc.contributor.author.fl_str_mv Badan,Gustavo Machado
Roveda Júnior,Décio
Ferreira,Carlos Alberto Pecci
Junior,Ozeas Alves de Noronha
dc.subject.por.fl_str_mv Breast cancer
Mammographic screening
BI-RADS
Audit of mammography service
Percutaneous biopsy
Positive predictive value
topic Breast cancer
Mammographic screening
BI-RADS
Audit of mammography service
Percutaneous biopsy
Positive predictive value
description Objective Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS®, in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Materials and Methods Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. Results The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. Conclusion The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.
publishDate 2014
dc.date.none.fl_str_mv 2014-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842014000200007
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842014000200007
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0100-39842014000200007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
dc.source.none.fl_str_mv Radiologia Brasileira v.47 n.2 2014
reponame:Radiologia Brasileira (Online)
instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron:CBR
instname_str Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron_str CBR
institution CBR
reponame_str Radiologia Brasileira (Online)
collection Radiologia Brasileira (Online)
repository.name.fl_str_mv Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
repository.mail.fl_str_mv radiologiabrasileira@cbr.org.br
_version_ 1754208938519166976