Quantification of Aerospace Polymer Blends by Thermogravimetric Analysis and Infrared Spectrometry

Detalhes bibliográficos
Autor(a) principal: Rigoli,Paulo Santos
Data de Publicação: 2019
Outros Autores: Murakami,Lídia Mattos Silva, Diniz,Milton Faria, Azevedo,Margarete Ferreira Prata, Cassu,Silvana Navarro, Mattos,Elizabeth da Costa, Dutra,Rita de Cássia Lazzarini
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of Aerospace Technology and Management (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2175-91462019000100304
Resumo: ABSTRACT Ethylene-propylene-diene elastomer (EPDM) is employed as thermal insulation for rocket motors, as well as EPDM blends with ethylene vinyl acetate (EVA) have been used in the aerospace industry. The quantification of these blends is more common using Fourier Transform Infrared Spectrometry (FT-IR) by transmission mode, but without discussing sample preparation and methodology error. Considering this fact, a methodology was developed for determining EVA content in binary blend with EPDM samples, by Universal Attenuated Total Reflection (UATR) technique, associated to thermogravimetric analysis (TGA). This last one, it was applied to determine Vinyl Acetate (VA) content in EVA and to identify differences between EPDM/EVA blends. Samples of the analyzed blends showed two VA contents and five proportions of EPDM/EVA: 90/10, 70/30, 50/50, 30/70, and 10/90. The carbonyl stretching vibration band C=O at 1740 cm-1 was used as analytical band in FT-IR quantification. Finally, the results presented excellent accuracy with a good linear correlation coefficient (R > 0.940) and with relative error values lower than 2%, respecting the precision limits of the FT-IR spectrometer.
id DCTA-1_de37f64705eabd9ea94227e5d753f147
oai_identifier_str oai:scielo:S2175-91462019000100304
network_acronym_str DCTA-1
network_name_str Journal of Aerospace Technology and Management (Online)
repository_id_str
spelling Quantification of Aerospace Polymer Blends by Thermogravimetric Analysis and Infrared SpectrometryEPDMEVAFT-IRQuantificationTGAABSTRACT Ethylene-propylene-diene elastomer (EPDM) is employed as thermal insulation for rocket motors, as well as EPDM blends with ethylene vinyl acetate (EVA) have been used in the aerospace industry. The quantification of these blends is more common using Fourier Transform Infrared Spectrometry (FT-IR) by transmission mode, but without discussing sample preparation and methodology error. Considering this fact, a methodology was developed for determining EVA content in binary blend with EPDM samples, by Universal Attenuated Total Reflection (UATR) technique, associated to thermogravimetric analysis (TGA). This last one, it was applied to determine Vinyl Acetate (VA) content in EVA and to identify differences between EPDM/EVA blends. Samples of the analyzed blends showed two VA contents and five proportions of EPDM/EVA: 90/10, 70/30, 50/50, 30/70, and 10/90. The carbonyl stretching vibration band C=O at 1740 cm-1 was used as analytical band in FT-IR quantification. Finally, the results presented excellent accuracy with a good linear correlation coefficient (R > 0.940) and with relative error values lower than 2%, respecting the precision limits of the FT-IR spectrometer.Departamento de Ciência e Tecnologia Aeroespacial2019-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2175-91462019000100304Journal of Aerospace Technology and Management v.11 2019reponame:Journal of Aerospace Technology and Management (Online)instname:Departamento de Ciência e Tecnologia Aeroespacial (DCTA)instacron:DCTA10.5028/jatm.v11.986info:eu-repo/semantics/openAccessRigoli,Paulo SantosMurakami,Lídia Mattos SilvaDiniz,Milton FariaAzevedo,Margarete Ferreira PrataCassu,Silvana NavarroMattos,Elizabeth da CostaDutra,Rita de Cássia Lazzarinieng2019-01-03T00:00:00Zoai:scielo:S2175-91462019000100304Revistahttp://www.jatm.com.br/ONGhttps://old.scielo.br/oai/scielo-oai.php||secretary@jatm.com.br2175-91461984-9648opendoar:2019-01-03T00:00Journal of Aerospace Technology and Management (Online) - Departamento de Ciência e Tecnologia Aeroespacial (DCTA)false
dc.title.none.fl_str_mv Quantification of Aerospace Polymer Blends by Thermogravimetric Analysis and Infrared Spectrometry
title Quantification of Aerospace Polymer Blends by Thermogravimetric Analysis and Infrared Spectrometry
spellingShingle Quantification of Aerospace Polymer Blends by Thermogravimetric Analysis and Infrared Spectrometry
Rigoli,Paulo Santos
EPDM
EVA
FT-IR
Quantification
TGA
title_short Quantification of Aerospace Polymer Blends by Thermogravimetric Analysis and Infrared Spectrometry
title_full Quantification of Aerospace Polymer Blends by Thermogravimetric Analysis and Infrared Spectrometry
title_fullStr Quantification of Aerospace Polymer Blends by Thermogravimetric Analysis and Infrared Spectrometry
title_full_unstemmed Quantification of Aerospace Polymer Blends by Thermogravimetric Analysis and Infrared Spectrometry
title_sort Quantification of Aerospace Polymer Blends by Thermogravimetric Analysis and Infrared Spectrometry
author Rigoli,Paulo Santos
author_facet Rigoli,Paulo Santos
Murakami,Lídia Mattos Silva
Diniz,Milton Faria
Azevedo,Margarete Ferreira Prata
Cassu,Silvana Navarro
Mattos,Elizabeth da Costa
Dutra,Rita de Cássia Lazzarini
author_role author
author2 Murakami,Lídia Mattos Silva
Diniz,Milton Faria
Azevedo,Margarete Ferreira Prata
Cassu,Silvana Navarro
Mattos,Elizabeth da Costa
Dutra,Rita de Cássia Lazzarini
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Rigoli,Paulo Santos
Murakami,Lídia Mattos Silva
Diniz,Milton Faria
Azevedo,Margarete Ferreira Prata
Cassu,Silvana Navarro
Mattos,Elizabeth da Costa
Dutra,Rita de Cássia Lazzarini
dc.subject.por.fl_str_mv EPDM
EVA
FT-IR
Quantification
TGA
topic EPDM
EVA
FT-IR
Quantification
TGA
description ABSTRACT Ethylene-propylene-diene elastomer (EPDM) is employed as thermal insulation for rocket motors, as well as EPDM blends with ethylene vinyl acetate (EVA) have been used in the aerospace industry. The quantification of these blends is more common using Fourier Transform Infrared Spectrometry (FT-IR) by transmission mode, but without discussing sample preparation and methodology error. Considering this fact, a methodology was developed for determining EVA content in binary blend with EPDM samples, by Universal Attenuated Total Reflection (UATR) technique, associated to thermogravimetric analysis (TGA). This last one, it was applied to determine Vinyl Acetate (VA) content in EVA and to identify differences between EPDM/EVA blends. Samples of the analyzed blends showed two VA contents and five proportions of EPDM/EVA: 90/10, 70/30, 50/50, 30/70, and 10/90. The carbonyl stretching vibration band C=O at 1740 cm-1 was used as analytical band in FT-IR quantification. Finally, the results presented excellent accuracy with a good linear correlation coefficient (R > 0.940) and with relative error values lower than 2%, respecting the precision limits of the FT-IR spectrometer.
publishDate 2019
dc.date.none.fl_str_mv 2019-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2175-91462019000100304
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2175-91462019000100304
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5028/jatm.v11.986
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Departamento de Ciência e Tecnologia Aeroespacial
publisher.none.fl_str_mv Departamento de Ciência e Tecnologia Aeroespacial
dc.source.none.fl_str_mv Journal of Aerospace Technology and Management v.11 2019
reponame:Journal of Aerospace Technology and Management (Online)
instname:Departamento de Ciência e Tecnologia Aeroespacial (DCTA)
instacron:DCTA
instname_str Departamento de Ciência e Tecnologia Aeroespacial (DCTA)
instacron_str DCTA
institution DCTA
reponame_str Journal of Aerospace Technology and Management (Online)
collection Journal of Aerospace Technology and Management (Online)
repository.name.fl_str_mv Journal of Aerospace Technology and Management (Online) - Departamento de Ciência e Tecnologia Aeroespacial (DCTA)
repository.mail.fl_str_mv ||secretary@jatm.com.br
_version_ 1754732532011630592