Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of details

Bibliographic Details
Main Author: BITENCOURT,Sandro Basso
Publication Date: 2021
Other Authors: CATANOZE,Isabela Araguê, SILVA,Emily Vivianne Freitas da, TURCIO,Karina Helga Leal, SANTOS,Daniela Micheline dos, BRANDINI,Daniela Atili, GOIATO,Marcelo Coelho, GUIOTTI,Aimée Maria
Format: Article
Language: eng
Source: Dental Press Journal of Orthodontics
Download full: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000300303
Summary: ABSTRACT Objective: This study aimed to evaluate the dimensional stability and maintenance of details of conventional and high stability alginates up to 5-day storage. Methods: Two types of alginates were selected (n=10) for this study, conventional (Hydrogum) and high stability alginates (Hydrogum 5), which were produced with the aid of a cylindrical metal block and a ring-shaped metal mold (Specifications 18, 19, and 25, ANSI/ADA). Ten images were obtained from the molds for the dimensional stability test, which were taken immediately after their production and at each different storage periods (15 min, 24 h, 48 h, 72 h, 96 h, and 120 h) by a digital camera. The specimens were kept hermetically sealed in plastic bags (23°C) and then used to obtain 140 (n=70) dental stone models, used in the detail reproduction test, in which the angular accuracy of three grooves (20 µm, 50 µm, and 75 µm) was observed at each period. The details reproduction accuracy was classified using a predetermined score classification. Measurements of dimensional changes were made in the Corel DRAW X6 program. The data were submitted to the Student’s t-test (α?#8197;= 0.05). Results: A statistically significant difference concerning the size of the matrix was observed after 24h for both alginates, and a statistically significant negative linear dimensional change (contraction) was verified after 24 h of storage (1.52% for the high stability alginate, and 1.32% for the conventional alginate). The high stability alginate kept the full details for 72 hours, while the conventional alginate, for 24 h. Both alginates reproduced the 75 µm groove at all storage periods. Conclusion: Impressions made with both alginates presented satisfactory clinical results when the alginates were immediately poured.
id DPI-1_312e5b240d080246b32f938b31ff7842
oai_identifier_str oai:scielo:S2176-94512021000300303
network_acronym_str DPI-1
network_name_str Dental Press Journal of Orthodontics
repository_id_str
spelling Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of detailsDimensional measurement accuracyAlginatesDental impression materialsABSTRACT Objective: This study aimed to evaluate the dimensional stability and maintenance of details of conventional and high stability alginates up to 5-day storage. Methods: Two types of alginates were selected (n=10) for this study, conventional (Hydrogum) and high stability alginates (Hydrogum 5), which were produced with the aid of a cylindrical metal block and a ring-shaped metal mold (Specifications 18, 19, and 25, ANSI/ADA). Ten images were obtained from the molds for the dimensional stability test, which were taken immediately after their production and at each different storage periods (15 min, 24 h, 48 h, 72 h, 96 h, and 120 h) by a digital camera. The specimens were kept hermetically sealed in plastic bags (23°C) and then used to obtain 140 (n=70) dental stone models, used in the detail reproduction test, in which the angular accuracy of three grooves (20 µm, 50 µm, and 75 µm) was observed at each period. The details reproduction accuracy was classified using a predetermined score classification. Measurements of dimensional changes were made in the Corel DRAW X6 program. The data were submitted to the Student’s t-test (α?#8197;= 0.05). Results: A statistically significant difference concerning the size of the matrix was observed after 24h for both alginates, and a statistically significant negative linear dimensional change (contraction) was verified after 24 h of storage (1.52% for the high stability alginate, and 1.32% for the conventional alginate). The high stability alginate kept the full details for 72 hours, while the conventional alginate, for 24 h. Both alginates reproduced the 75 µm groove at all storage periods. Conclusion: Impressions made with both alginates presented satisfactory clinical results when the alginates were immediately poured.Dental Press International2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000300303Dental Press Journal of Orthodontics v.26 n.3 2021reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/2177-6709.26.3.e2119251.oarinfo:eu-repo/semantics/openAccessBITENCOURT,Sandro BassoCATANOZE,Isabela AraguêSILVA,Emily Vivianne Freitas daTURCIO,Karina Helga LealSANTOS,Daniela Micheline dosBRANDINI,Daniela AtiliGOIATO,Marcelo CoelhoGUIOTTI,Aimée Mariaeng2021-06-28T00:00:00Zoai:scielo:S2176-94512021000300303Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2021-06-28T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false
dc.title.none.fl_str_mv Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of details
title Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of details
spellingShingle Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of details
BITENCOURT,Sandro Basso
Dimensional measurement accuracy
Alginates
Dental impression materials
title_short Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of details
title_full Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of details
title_fullStr Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of details
title_full_unstemmed Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of details
title_sort Extended-pour and conventional alginates: effect of storage time on dimensional accuracy and maintenance of details
author BITENCOURT,Sandro Basso
author_facet BITENCOURT,Sandro Basso
CATANOZE,Isabela Araguê
SILVA,Emily Vivianne Freitas da
TURCIO,Karina Helga Leal
SANTOS,Daniela Micheline dos
BRANDINI,Daniela Atili
GOIATO,Marcelo Coelho
GUIOTTI,Aimée Maria
author_role author
author2 CATANOZE,Isabela Araguê
SILVA,Emily Vivianne Freitas da
TURCIO,Karina Helga Leal
SANTOS,Daniela Micheline dos
BRANDINI,Daniela Atili
GOIATO,Marcelo Coelho
GUIOTTI,Aimée Maria
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv BITENCOURT,Sandro Basso
CATANOZE,Isabela Araguê
SILVA,Emily Vivianne Freitas da
TURCIO,Karina Helga Leal
SANTOS,Daniela Micheline dos
BRANDINI,Daniela Atili
GOIATO,Marcelo Coelho
GUIOTTI,Aimée Maria
dc.subject.por.fl_str_mv Dimensional measurement accuracy
Alginates
Dental impression materials
topic Dimensional measurement accuracy
Alginates
Dental impression materials
description ABSTRACT Objective: This study aimed to evaluate the dimensional stability and maintenance of details of conventional and high stability alginates up to 5-day storage. Methods: Two types of alginates were selected (n=10) for this study, conventional (Hydrogum) and high stability alginates (Hydrogum 5), which were produced with the aid of a cylindrical metal block and a ring-shaped metal mold (Specifications 18, 19, and 25, ANSI/ADA). Ten images were obtained from the molds for the dimensional stability test, which were taken immediately after their production and at each different storage periods (15 min, 24 h, 48 h, 72 h, 96 h, and 120 h) by a digital camera. The specimens were kept hermetically sealed in plastic bags (23°C) and then used to obtain 140 (n=70) dental stone models, used in the detail reproduction test, in which the angular accuracy of three grooves (20 µm, 50 µm, and 75 µm) was observed at each period. The details reproduction accuracy was classified using a predetermined score classification. Measurements of dimensional changes were made in the Corel DRAW X6 program. The data were submitted to the Student’s t-test (α?#8197;= 0.05). Results: A statistically significant difference concerning the size of the matrix was observed after 24h for both alginates, and a statistically significant negative linear dimensional change (contraction) was verified after 24 h of storage (1.52% for the high stability alginate, and 1.32% for the conventional alginate). The high stability alginate kept the full details for 72 hours, while the conventional alginate, for 24 h. Both alginates reproduced the 75 µm groove at all storage periods. Conclusion: Impressions made with both alginates presented satisfactory clinical results when the alginates were immediately poured.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000300303
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000300303
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/2177-6709.26.3.e2119251.oar
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Dental Press International
publisher.none.fl_str_mv Dental Press International
dc.source.none.fl_str_mv Dental Press Journal of Orthodontics v.26 n.3 2021
reponame:Dental Press Journal of Orthodontics
instname:Dental Press International (DPI)
instacron:DPI
instname_str Dental Press International (DPI)
instacron_str DPI
institution DPI
reponame_str Dental Press Journal of Orthodontics
collection Dental Press Journal of Orthodontics
repository.name.fl_str_mv Dental Press Journal of Orthodontics - Dental Press International (DPI)
repository.mail.fl_str_mv artigos@dentalpress.com.br||davidnormando@hotmail.com
_version_ 1754122398927421440