A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition

Detalhes bibliográficos
Autor(a) principal: Bhattad,Mayur S.
Data de Publicação: 2015
Outros Autores: Baliga,Sudhindra, Vibhute,Pavan
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Dental Press Journal of Orthodontics
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512015000200055
Resumo: OBJECTIVE: To assess bone thickness for miniscrew placement in the mandible during mixed dentition by using digital volumetric tomograph (DVT). MATERIAL AND METHODS: A total of 15 healthy patients aged 8-10 years old, with early exfoliated mandibular second deciduous molar, were included. DVT images of one quadrant of the mandible were obtained using Kodak extraoral imaging systems and analyzed by Kodak dental imaging software. The error of the method (EM) was calculated using Dahlberg's formula. Mean and standard deviation were calculated at 6 and 8 mm from the cementoenamel junction (CEJ).Paired t-test was used to analyze the measurements. RESULTS: Buccal cortical bone thickness, mesiodistal width and buccolingual bone depth at 6 mm were found to be 1.73 + 0.41, 2.15 + 0.49 and 13.18 + 1.22 mm, respectively; while at 8 mm measurements were 2.42 + 0.34, 2.48 + 0.33 and 13.65 + 1.25 mm, respectively. EM for buccal cortical bone thickness, mesiodistal width and buccolingual bone depth was 0.58, 0.40 and 0.48, respectively. The difference in measurement at 6 and 8 mm for buccal cortical plate thickness (P < 0.05) and buccolingual bone thickness (P < 0.05) was found to be significant, whereas for mesiodistal width it was insignificant (P > 0.05). CONCLUSION: Bone thickness measurement has shown promising evidence for safe placement of miniscrews in the mandible during mixed dentition. The use of miniscrew is the best alternative, even in younger patients.
id DPI-1_a2d54f9a9f55dcaf300d638b281f74be
oai_identifier_str oai:scielo:S2176-94512015000200055
network_acronym_str DPI-1
network_name_str Dental Press Journal of Orthodontics
repository_id_str
spelling A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentitionMiniscrewsDigital volumetric tomographInter-radicular boneCortical bone OBJECTIVE: To assess bone thickness for miniscrew placement in the mandible during mixed dentition by using digital volumetric tomograph (DVT). MATERIAL AND METHODS: A total of 15 healthy patients aged 8-10 years old, with early exfoliated mandibular second deciduous molar, were included. DVT images of one quadrant of the mandible were obtained using Kodak extraoral imaging systems and analyzed by Kodak dental imaging software. The error of the method (EM) was calculated using Dahlberg's formula. Mean and standard deviation were calculated at 6 and 8 mm from the cementoenamel junction (CEJ).Paired t-test was used to analyze the measurements. RESULTS: Buccal cortical bone thickness, mesiodistal width and buccolingual bone depth at 6 mm were found to be 1.73 + 0.41, 2.15 + 0.49 and 13.18 + 1.22 mm, respectively; while at 8 mm measurements were 2.42 + 0.34, 2.48 + 0.33 and 13.65 + 1.25 mm, respectively. EM for buccal cortical bone thickness, mesiodistal width and buccolingual bone depth was 0.58, 0.40 and 0.48, respectively. The difference in measurement at 6 and 8 mm for buccal cortical plate thickness (P < 0.05) and buccolingual bone thickness (P < 0.05) was found to be significant, whereas for mesiodistal width it was insignificant (P > 0.05). CONCLUSION: Bone thickness measurement has shown promising evidence for safe placement of miniscrews in the mandible during mixed dentition. The use of miniscrew is the best alternative, even in younger patients. Dental Press International2015-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512015000200055Dental Press Journal of Orthodontics v.20 n.2 2015reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/2176-9451.20.2.055-060.oarinfo:eu-repo/semantics/openAccessBhattad,Mayur S.Baliga,SudhindraVibhute,Pavaneng2015-09-01T00:00:00Zoai:scielo:S2176-94512015000200055Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2015-09-01T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false
dc.title.none.fl_str_mv A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition
title A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition
spellingShingle A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition
Bhattad,Mayur S.
Miniscrews
Digital volumetric tomograph
Inter-radicular bone
Cortical bone
title_short A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition
title_full A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition
title_fullStr A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition
title_full_unstemmed A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition
title_sort A digital volumetric tomography (DVT) study in the mandibular molar region for miniscrew placement during mixed dentition
author Bhattad,Mayur S.
author_facet Bhattad,Mayur S.
Baliga,Sudhindra
Vibhute,Pavan
author_role author
author2 Baliga,Sudhindra
Vibhute,Pavan
author2_role author
author
dc.contributor.author.fl_str_mv Bhattad,Mayur S.
Baliga,Sudhindra
Vibhute,Pavan
dc.subject.por.fl_str_mv Miniscrews
Digital volumetric tomograph
Inter-radicular bone
Cortical bone
topic Miniscrews
Digital volumetric tomograph
Inter-radicular bone
Cortical bone
description OBJECTIVE: To assess bone thickness for miniscrew placement in the mandible during mixed dentition by using digital volumetric tomograph (DVT). MATERIAL AND METHODS: A total of 15 healthy patients aged 8-10 years old, with early exfoliated mandibular second deciduous molar, were included. DVT images of one quadrant of the mandible were obtained using Kodak extraoral imaging systems and analyzed by Kodak dental imaging software. The error of the method (EM) was calculated using Dahlberg's formula. Mean and standard deviation were calculated at 6 and 8 mm from the cementoenamel junction (CEJ).Paired t-test was used to analyze the measurements. RESULTS: Buccal cortical bone thickness, mesiodistal width and buccolingual bone depth at 6 mm were found to be 1.73 + 0.41, 2.15 + 0.49 and 13.18 + 1.22 mm, respectively; while at 8 mm measurements were 2.42 + 0.34, 2.48 + 0.33 and 13.65 + 1.25 mm, respectively. EM for buccal cortical bone thickness, mesiodistal width and buccolingual bone depth was 0.58, 0.40 and 0.48, respectively. The difference in measurement at 6 and 8 mm for buccal cortical plate thickness (P < 0.05) and buccolingual bone thickness (P < 0.05) was found to be significant, whereas for mesiodistal width it was insignificant (P > 0.05). CONCLUSION: Bone thickness measurement has shown promising evidence for safe placement of miniscrews in the mandible during mixed dentition. The use of miniscrew is the best alternative, even in younger patients.
publishDate 2015
dc.date.none.fl_str_mv 2015-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512015000200055
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512015000200055
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/2176-9451.20.2.055-060.oar
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Dental Press International
publisher.none.fl_str_mv Dental Press International
dc.source.none.fl_str_mv Dental Press Journal of Orthodontics v.20 n.2 2015
reponame:Dental Press Journal of Orthodontics
instname:Dental Press International (DPI)
instacron:DPI
instname_str Dental Press International (DPI)
instacron_str DPI
institution DPI
reponame_str Dental Press Journal of Orthodontics
collection Dental Press Journal of Orthodontics
repository.name.fl_str_mv Dental Press Journal of Orthodontics - Dental Press International (DPI)
repository.mail.fl_str_mv artigos@dentalpress.com.br||davidnormando@hotmail.com
_version_ 1754122397237116928