Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study

Detalhes bibliográficos
Autor(a) principal: GESHAY,Danielle
Data de Publicação: 2021
Outros Autores: CAMPBELL,Phillip, TADLOCK,Larry, SCHNEIDERMAN,Emet, KYUNG,Hee-Moon, BUSCHANG,Peter
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Dental Press Journal of Orthodontics
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000100311
Resumo: ABSTRACT Introduction: Shorter miniscrew implants (MSIs) are needed to make orthodontics more effective and efficient. Objective: To evaluate the stability, insertion torque, removal torque and pain associated with 3 mm long MSIs placed in humans by a novice clinician. Methods: 82 MSIs were placed in the buccal maxillae of 26 adults. Pairs of adjacent implants were immediately loaded with 100g. Subjects were recalled after 1, 3, 5, and 8 weeks to verify stability and complete questionnaires pertaining to MSI-related pain and discomfort. Results: The overall failure rate was 32.9%. The anterior and posterior MSIs failed 35.7% and 30.0% of the time, respectively. Excluding the 10 MSIs (12.2%) that were traumatically dislodged, the failure rates in the anterior and posterior sites were 30.1% and 15.2%, respectively; the overall primary failure rate was 23.6%. Failures were significantly (p= 0.010) greater (46.3% vs 19.5%) among the first 41 MSIs than the last 41 MSIs that were placed. Excluding the traumatically lost MSIs, the failures occurred on or before day 42. Subjects experienced very low pain (2.2% of maximum) and discomfort (5.5% of maximum) during the first week only. Conclusions: Shorter 3 mm MSIs placed by a novice operator are highly likely to fail. However, failure rates can be substantially decreased over time with the placement of more MSIs. Pain and discomfort experienced after placing 3 mm MSIs is minimal and temporary.
id DPI-1_d913378df9fb3052a078e3ba9a81317a
oai_identifier_str oai:scielo:S2176-94512021000100311
network_acronym_str DPI-1
network_name_str Dental Press Journal of Orthodontics
repository_id_str
spelling Stability of immediately loaded 3 mm long miniscrew implants: a feasibility studyMiniscrew implantsStabilityPain/discomfortExperienceABSTRACT Introduction: Shorter miniscrew implants (MSIs) are needed to make orthodontics more effective and efficient. Objective: To evaluate the stability, insertion torque, removal torque and pain associated with 3 mm long MSIs placed in humans by a novice clinician. Methods: 82 MSIs were placed in the buccal maxillae of 26 adults. Pairs of adjacent implants were immediately loaded with 100g. Subjects were recalled after 1, 3, 5, and 8 weeks to verify stability and complete questionnaires pertaining to MSI-related pain and discomfort. Results: The overall failure rate was 32.9%. The anterior and posterior MSIs failed 35.7% and 30.0% of the time, respectively. Excluding the 10 MSIs (12.2%) that were traumatically dislodged, the failure rates in the anterior and posterior sites were 30.1% and 15.2%, respectively; the overall primary failure rate was 23.6%. Failures were significantly (p= 0.010) greater (46.3% vs 19.5%) among the first 41 MSIs than the last 41 MSIs that were placed. Excluding the traumatically lost MSIs, the failures occurred on or before day 42. Subjects experienced very low pain (2.2% of maximum) and discomfort (5.5% of maximum) during the first week only. Conclusions: Shorter 3 mm MSIs placed by a novice operator are highly likely to fail. However, failure rates can be substantially decreased over time with the placement of more MSIs. Pain and discomfort experienced after placing 3 mm MSIs is minimal and temporary.Dental Press International2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000100311Dental Press Journal of Orthodontics v.26 n.1 2021reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/2177-6709.26.1.e2119155.oarinfo:eu-repo/semantics/openAccessGESHAY,DanielleCAMPBELL,PhillipTADLOCK,LarrySCHNEIDERMAN,EmetKYUNG,Hee-MoonBUSCHANG,Petereng2021-03-18T00:00:00Zoai:scielo:S2176-94512021000100311Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2021-03-18T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false
dc.title.none.fl_str_mv Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study
title Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study
spellingShingle Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study
GESHAY,Danielle
Miniscrew implants
Stability
Pain/discomfort
Experience
title_short Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study
title_full Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study
title_fullStr Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study
title_full_unstemmed Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study
title_sort Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study
author GESHAY,Danielle
author_facet GESHAY,Danielle
CAMPBELL,Phillip
TADLOCK,Larry
SCHNEIDERMAN,Emet
KYUNG,Hee-Moon
BUSCHANG,Peter
author_role author
author2 CAMPBELL,Phillip
TADLOCK,Larry
SCHNEIDERMAN,Emet
KYUNG,Hee-Moon
BUSCHANG,Peter
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv GESHAY,Danielle
CAMPBELL,Phillip
TADLOCK,Larry
SCHNEIDERMAN,Emet
KYUNG,Hee-Moon
BUSCHANG,Peter
dc.subject.por.fl_str_mv Miniscrew implants
Stability
Pain/discomfort
Experience
topic Miniscrew implants
Stability
Pain/discomfort
Experience
description ABSTRACT Introduction: Shorter miniscrew implants (MSIs) are needed to make orthodontics more effective and efficient. Objective: To evaluate the stability, insertion torque, removal torque and pain associated with 3 mm long MSIs placed in humans by a novice clinician. Methods: 82 MSIs were placed in the buccal maxillae of 26 adults. Pairs of adjacent implants were immediately loaded with 100g. Subjects were recalled after 1, 3, 5, and 8 weeks to verify stability and complete questionnaires pertaining to MSI-related pain and discomfort. Results: The overall failure rate was 32.9%. The anterior and posterior MSIs failed 35.7% and 30.0% of the time, respectively. Excluding the 10 MSIs (12.2%) that were traumatically dislodged, the failure rates in the anterior and posterior sites were 30.1% and 15.2%, respectively; the overall primary failure rate was 23.6%. Failures were significantly (p= 0.010) greater (46.3% vs 19.5%) among the first 41 MSIs than the last 41 MSIs that were placed. Excluding the traumatically lost MSIs, the failures occurred on or before day 42. Subjects experienced very low pain (2.2% of maximum) and discomfort (5.5% of maximum) during the first week only. Conclusions: Shorter 3 mm MSIs placed by a novice operator are highly likely to fail. However, failure rates can be substantially decreased over time with the placement of more MSIs. Pain and discomfort experienced after placing 3 mm MSIs is minimal and temporary.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000100311
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000100311
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/2177-6709.26.1.e2119155.oar
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Dental Press International
publisher.none.fl_str_mv Dental Press International
dc.source.none.fl_str_mv Dental Press Journal of Orthodontics v.26 n.1 2021
reponame:Dental Press Journal of Orthodontics
instname:Dental Press International (DPI)
instacron:DPI
instname_str Dental Press International (DPI)
instacron_str DPI
institution DPI
reponame_str Dental Press Journal of Orthodontics
collection Dental Press Journal of Orthodontics
repository.name.fl_str_mv Dental Press Journal of Orthodontics - Dental Press International (DPI)
repository.mail.fl_str_mv artigos@dentalpress.com.br||davidnormando@hotmail.com
_version_ 1754122398893867008