Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study
Autor(a) principal: | |
---|---|
Data de Publicação: | 2021 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Dental Press Journal of Orthodontics |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000100311 |
Resumo: | ABSTRACT Introduction: Shorter miniscrew implants (MSIs) are needed to make orthodontics more effective and efficient. Objective: To evaluate the stability, insertion torque, removal torque and pain associated with 3 mm long MSIs placed in humans by a novice clinician. Methods: 82 MSIs were placed in the buccal maxillae of 26 adults. Pairs of adjacent implants were immediately loaded with 100g. Subjects were recalled after 1, 3, 5, and 8 weeks to verify stability and complete questionnaires pertaining to MSI-related pain and discomfort. Results: The overall failure rate was 32.9%. The anterior and posterior MSIs failed 35.7% and 30.0% of the time, respectively. Excluding the 10 MSIs (12.2%) that were traumatically dislodged, the failure rates in the anterior and posterior sites were 30.1% and 15.2%, respectively; the overall primary failure rate was 23.6%. Failures were significantly (p= 0.010) greater (46.3% vs 19.5%) among the first 41 MSIs than the last 41 MSIs that were placed. Excluding the traumatically lost MSIs, the failures occurred on or before day 42. Subjects experienced very low pain (2.2% of maximum) and discomfort (5.5% of maximum) during the first week only. Conclusions: Shorter 3 mm MSIs placed by a novice operator are highly likely to fail. However, failure rates can be substantially decreased over time with the placement of more MSIs. Pain and discomfort experienced after placing 3 mm MSIs is minimal and temporary. |
id |
DPI-1_d913378df9fb3052a078e3ba9a81317a |
---|---|
oai_identifier_str |
oai:scielo:S2176-94512021000100311 |
network_acronym_str |
DPI-1 |
network_name_str |
Dental Press Journal of Orthodontics |
repository_id_str |
|
spelling |
Stability of immediately loaded 3 mm long miniscrew implants: a feasibility studyMiniscrew implantsStabilityPain/discomfortExperienceABSTRACT Introduction: Shorter miniscrew implants (MSIs) are needed to make orthodontics more effective and efficient. Objective: To evaluate the stability, insertion torque, removal torque and pain associated with 3 mm long MSIs placed in humans by a novice clinician. Methods: 82 MSIs were placed in the buccal maxillae of 26 adults. Pairs of adjacent implants were immediately loaded with 100g. Subjects were recalled after 1, 3, 5, and 8 weeks to verify stability and complete questionnaires pertaining to MSI-related pain and discomfort. Results: The overall failure rate was 32.9%. The anterior and posterior MSIs failed 35.7% and 30.0% of the time, respectively. Excluding the 10 MSIs (12.2%) that were traumatically dislodged, the failure rates in the anterior and posterior sites were 30.1% and 15.2%, respectively; the overall primary failure rate was 23.6%. Failures were significantly (p= 0.010) greater (46.3% vs 19.5%) among the first 41 MSIs than the last 41 MSIs that were placed. Excluding the traumatically lost MSIs, the failures occurred on or before day 42. Subjects experienced very low pain (2.2% of maximum) and discomfort (5.5% of maximum) during the first week only. Conclusions: Shorter 3 mm MSIs placed by a novice operator are highly likely to fail. However, failure rates can be substantially decreased over time with the placement of more MSIs. Pain and discomfort experienced after placing 3 mm MSIs is minimal and temporary.Dental Press International2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000100311Dental Press Journal of Orthodontics v.26 n.1 2021reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/2177-6709.26.1.e2119155.oarinfo:eu-repo/semantics/openAccessGESHAY,DanielleCAMPBELL,PhillipTADLOCK,LarrySCHNEIDERMAN,EmetKYUNG,Hee-MoonBUSCHANG,Petereng2021-03-18T00:00:00Zoai:scielo:S2176-94512021000100311Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2021-03-18T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false |
dc.title.none.fl_str_mv |
Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study |
title |
Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study |
spellingShingle |
Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study GESHAY,Danielle Miniscrew implants Stability Pain/discomfort Experience |
title_short |
Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study |
title_full |
Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study |
title_fullStr |
Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study |
title_full_unstemmed |
Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study |
title_sort |
Stability of immediately loaded 3 mm long miniscrew implants: a feasibility study |
author |
GESHAY,Danielle |
author_facet |
GESHAY,Danielle CAMPBELL,Phillip TADLOCK,Larry SCHNEIDERMAN,Emet KYUNG,Hee-Moon BUSCHANG,Peter |
author_role |
author |
author2 |
CAMPBELL,Phillip TADLOCK,Larry SCHNEIDERMAN,Emet KYUNG,Hee-Moon BUSCHANG,Peter |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
GESHAY,Danielle CAMPBELL,Phillip TADLOCK,Larry SCHNEIDERMAN,Emet KYUNG,Hee-Moon BUSCHANG,Peter |
dc.subject.por.fl_str_mv |
Miniscrew implants Stability Pain/discomfort Experience |
topic |
Miniscrew implants Stability Pain/discomfort Experience |
description |
ABSTRACT Introduction: Shorter miniscrew implants (MSIs) are needed to make orthodontics more effective and efficient. Objective: To evaluate the stability, insertion torque, removal torque and pain associated with 3 mm long MSIs placed in humans by a novice clinician. Methods: 82 MSIs were placed in the buccal maxillae of 26 adults. Pairs of adjacent implants were immediately loaded with 100g. Subjects were recalled after 1, 3, 5, and 8 weeks to verify stability and complete questionnaires pertaining to MSI-related pain and discomfort. Results: The overall failure rate was 32.9%. The anterior and posterior MSIs failed 35.7% and 30.0% of the time, respectively. Excluding the 10 MSIs (12.2%) that were traumatically dislodged, the failure rates in the anterior and posterior sites were 30.1% and 15.2%, respectively; the overall primary failure rate was 23.6%. Failures were significantly (p= 0.010) greater (46.3% vs 19.5%) among the first 41 MSIs than the last 41 MSIs that were placed. Excluding the traumatically lost MSIs, the failures occurred on or before day 42. Subjects experienced very low pain (2.2% of maximum) and discomfort (5.5% of maximum) during the first week only. Conclusions: Shorter 3 mm MSIs placed by a novice operator are highly likely to fail. However, failure rates can be substantially decreased over time with the placement of more MSIs. Pain and discomfort experienced after placing 3 mm MSIs is minimal and temporary. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000100311 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512021000100311 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/2177-6709.26.1.e2119155.oar |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Dental Press International |
publisher.none.fl_str_mv |
Dental Press International |
dc.source.none.fl_str_mv |
Dental Press Journal of Orthodontics v.26 n.1 2021 reponame:Dental Press Journal of Orthodontics instname:Dental Press International (DPI) instacron:DPI |
instname_str |
Dental Press International (DPI) |
instacron_str |
DPI |
institution |
DPI |
reponame_str |
Dental Press Journal of Orthodontics |
collection |
Dental Press Journal of Orthodontics |
repository.name.fl_str_mv |
Dental Press Journal of Orthodontics - Dental Press International (DPI) |
repository.mail.fl_str_mv |
artigos@dentalpress.com.br||davidnormando@hotmail.com |
_version_ |
1754122398893867008 |