Pain, masticatory performance and swallowing threshold in orthodontic patients

Detalhes bibliográficos
Autor(a) principal: Trein,Marcos Porto
Data de Publicação: 2013
Outros Autores: Mundstock,Karina Santos, Maciel,Leonardo, Rachor,Jaqueline, Gameiro,Gustavo Hauber
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Dental Press Journal of Orthodontics
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000600018
Resumo: OBJECTIVE: The aim of this study was to assess pain, masticatory performance and swallowing threshold of patients undergoing orthodontic treatment. METHODS: Ten patients of both genders (mean age of 17.25 ± 5.21 years), with complete permanent dentition, who underwent orthodontic treatment with fixed appliances were evaluated. The masticatory performance and the swallowing threshold were assessed by patient's individual capacity of fragmenting an artificial test food (Optocal) which was chewed and had the resulting particles processed by a standardized sieving method, presenting the median particle size (MPS) of crushed units. The intensity of pain / discomfort during chewing was evaluated by means of a visual analog scale. All tests were performed at the following times: T0 - before activating the orthodontic appliance; T1 - 24 hours after activation, and T2 - 30 days after activation. RESULTS: The results showed a significant increase in pain at T1 (T0 - 0.60 ± 0.70 mm; T1 - 66.2 ± 34.5 mm), returning to baseline values at T2 (3.20 ± 3.82 mm). Masticatory performance was also reduced in T1 (MPS 10.15 ± 1.1 mm²) in comparison to T0 (MPS 7.01 ± 2.9 mm²) and T2 (MPS 6.76 ± 1.3 mm²). However, particle size was not affected in the swallowing threshold test (T0 - 5.47 ± 2.37 mm²; T1 - 6.19 ± 2.05 mm²; T2 - 5.94 ± 2.36 mm²). CONCLUSION: The orthodontic appliances did not interfere in the size of the particles that would be swallowed, even in the presence of pain.
id DPI-1_dcd10f150aebd47a61c5ccdb0fe9ea52
oai_identifier_str oai:scielo:S2176-94512013000600018
network_acronym_str DPI-1
network_name_str Dental Press Journal of Orthodontics
repository_id_str
spelling Pain, masticatory performance and swallowing threshold in orthodontic patientsMasticationMalocclusionOrthodonticsOBJECTIVE: The aim of this study was to assess pain, masticatory performance and swallowing threshold of patients undergoing orthodontic treatment. METHODS: Ten patients of both genders (mean age of 17.25 ± 5.21 years), with complete permanent dentition, who underwent orthodontic treatment with fixed appliances were evaluated. The masticatory performance and the swallowing threshold were assessed by patient's individual capacity of fragmenting an artificial test food (Optocal) which was chewed and had the resulting particles processed by a standardized sieving method, presenting the median particle size (MPS) of crushed units. The intensity of pain / discomfort during chewing was evaluated by means of a visual analog scale. All tests were performed at the following times: T0 - before activating the orthodontic appliance; T1 - 24 hours after activation, and T2 - 30 days after activation. RESULTS: The results showed a significant increase in pain at T1 (T0 - 0.60 ± 0.70 mm; T1 - 66.2 ± 34.5 mm), returning to baseline values at T2 (3.20 ± 3.82 mm). Masticatory performance was also reduced in T1 (MPS 10.15 ± 1.1 mm²) in comparison to T0 (MPS 7.01 ± 2.9 mm²) and T2 (MPS 6.76 ± 1.3 mm²). However, particle size was not affected in the swallowing threshold test (T0 - 5.47 ± 2.37 mm²; T1 - 6.19 ± 2.05 mm²; T2 - 5.94 ± 2.36 mm²). CONCLUSION: The orthodontic appliances did not interfere in the size of the particles that would be swallowed, even in the presence of pain.Dental Press International2013-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000600018Dental Press Journal of Orthodontics v.18 n.6 2013reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/S2176-94512013000600018info:eu-repo/semantics/openAccessTrein,Marcos PortoMundstock,Karina SantosMaciel,LeonardoRachor,JaquelineGameiro,Gustavo Haubereng2015-07-02T00:00:00Zoai:scielo:S2176-94512013000600018Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2015-07-02T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false
dc.title.none.fl_str_mv Pain, masticatory performance and swallowing threshold in orthodontic patients
title Pain, masticatory performance and swallowing threshold in orthodontic patients
spellingShingle Pain, masticatory performance and swallowing threshold in orthodontic patients
Trein,Marcos Porto
Mastication
Malocclusion
Orthodontics
title_short Pain, masticatory performance and swallowing threshold in orthodontic patients
title_full Pain, masticatory performance and swallowing threshold in orthodontic patients
title_fullStr Pain, masticatory performance and swallowing threshold in orthodontic patients
title_full_unstemmed Pain, masticatory performance and swallowing threshold in orthodontic patients
title_sort Pain, masticatory performance and swallowing threshold in orthodontic patients
author Trein,Marcos Porto
author_facet Trein,Marcos Porto
Mundstock,Karina Santos
Maciel,Leonardo
Rachor,Jaqueline
Gameiro,Gustavo Hauber
author_role author
author2 Mundstock,Karina Santos
Maciel,Leonardo
Rachor,Jaqueline
Gameiro,Gustavo Hauber
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Trein,Marcos Porto
Mundstock,Karina Santos
Maciel,Leonardo
Rachor,Jaqueline
Gameiro,Gustavo Hauber
dc.subject.por.fl_str_mv Mastication
Malocclusion
Orthodontics
topic Mastication
Malocclusion
Orthodontics
description OBJECTIVE: The aim of this study was to assess pain, masticatory performance and swallowing threshold of patients undergoing orthodontic treatment. METHODS: Ten patients of both genders (mean age of 17.25 ± 5.21 years), with complete permanent dentition, who underwent orthodontic treatment with fixed appliances were evaluated. The masticatory performance and the swallowing threshold were assessed by patient's individual capacity of fragmenting an artificial test food (Optocal) which was chewed and had the resulting particles processed by a standardized sieving method, presenting the median particle size (MPS) of crushed units. The intensity of pain / discomfort during chewing was evaluated by means of a visual analog scale. All tests were performed at the following times: T0 - before activating the orthodontic appliance; T1 - 24 hours after activation, and T2 - 30 days after activation. RESULTS: The results showed a significant increase in pain at T1 (T0 - 0.60 ± 0.70 mm; T1 - 66.2 ± 34.5 mm), returning to baseline values at T2 (3.20 ± 3.82 mm). Masticatory performance was also reduced in T1 (MPS 10.15 ± 1.1 mm²) in comparison to T0 (MPS 7.01 ± 2.9 mm²) and T2 (MPS 6.76 ± 1.3 mm²). However, particle size was not affected in the swallowing threshold test (T0 - 5.47 ± 2.37 mm²; T1 - 6.19 ± 2.05 mm²; T2 - 5.94 ± 2.36 mm²). CONCLUSION: The orthodontic appliances did not interfere in the size of the particles that would be swallowed, even in the presence of pain.
publishDate 2013
dc.date.none.fl_str_mv 2013-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000600018
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512013000600018
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S2176-94512013000600018
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Dental Press International
publisher.none.fl_str_mv Dental Press International
dc.source.none.fl_str_mv Dental Press Journal of Orthodontics v.18 n.6 2013
reponame:Dental Press Journal of Orthodontics
instname:Dental Press International (DPI)
instacron:DPI
instname_str Dental Press International (DPI)
instacron_str DPI
institution DPI
reponame_str Dental Press Journal of Orthodontics
collection Dental Press Journal of Orthodontics
repository.name.fl_str_mv Dental Press Journal of Orthodontics - Dental Press International (DPI)
repository.mail.fl_str_mv artigos@dentalpress.com.br||davidnormando@hotmail.com
_version_ 1754122396798812160