Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA)

Detalhes bibliográficos
Autor(a) principal: Schwertner,Alessandro
Data de Publicação: 2017
Outros Autores: Almeida,Renato Rodrigues de, Gonini Jr,Alcides, Almeida,Marcio Rodrigues de
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Dental Press Journal of Orthodontics
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512017000100057
Resumo: ABSTRACT Objective: The present in vitro study evaluated, by means of the photoelastic technique, the effects generated by the Connecticut Intrusion Arch (CIA), with a 90o bend on the distal surface of molar tubes and using the 4 x 2 appliance on the anterior and posterior regions of the upper dental arch. Methods: Five models were manufactured, in which two different clinical situations were correlated: 1) use of intrusion arch not cinched back and transpalatal bar for anchorage (Group 1); 2) use of intrusion arch cinched back and transpalatal bar for anchorage (Group 2). Stress generated in the apical and middle regions of tooth roots of maxillary anterior teeth and maxillary first molars was evaluated. Results: Taking a reference value of 1.0 MPa = 100%, qualitative descriptive analysis was performed, which showed uniformity between stress values in the apical region of anterior teeth of both groups (G1 and G2). In the posterior region, for models with the arch cinched back (G2), stress remained within 100%. As for G1 models (with the arch not cinched back), variations in the mesial surface of first molars were observed, with an increase of 20% in the generated stress. The apical region did not undergo any changes, while in the distal region of molars there was a decrease of 20% in stress. Conclusion: Laboratory results revealed differences in stress between Groups 1 and 2 in the molar region, thereby indicating that there was a tendency towards mesial root tipping of first molars when the distal end of the CIA was not cinched back.
id DPI-1_f6d53f3952069b78949f28719d618cd8
oai_identifier_str oai:scielo:S2176-94512017000100057
network_acronym_str DPI-1
network_name_str Dental Press Journal of Orthodontics
repository_id_str
spelling Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA)Intrusion archPhotoelasticityPhysical properties.ABSTRACT Objective: The present in vitro study evaluated, by means of the photoelastic technique, the effects generated by the Connecticut Intrusion Arch (CIA), with a 90o bend on the distal surface of molar tubes and using the 4 x 2 appliance on the anterior and posterior regions of the upper dental arch. Methods: Five models were manufactured, in which two different clinical situations were correlated: 1) use of intrusion arch not cinched back and transpalatal bar for anchorage (Group 1); 2) use of intrusion arch cinched back and transpalatal bar for anchorage (Group 2). Stress generated in the apical and middle regions of tooth roots of maxillary anterior teeth and maxillary first molars was evaluated. Results: Taking a reference value of 1.0 MPa = 100%, qualitative descriptive analysis was performed, which showed uniformity between stress values in the apical region of anterior teeth of both groups (G1 and G2). In the posterior region, for models with the arch cinched back (G2), stress remained within 100%. As for G1 models (with the arch not cinched back), variations in the mesial surface of first molars were observed, with an increase of 20% in the generated stress. The apical region did not undergo any changes, while in the distal region of molars there was a decrease of 20% in stress. Conclusion: Laboratory results revealed differences in stress between Groups 1 and 2 in the molar region, thereby indicating that there was a tendency towards mesial root tipping of first molars when the distal end of the CIA was not cinched back.Dental Press International2017-02-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512017000100057Dental Press Journal of Orthodontics v.22 n.1 2017reponame:Dental Press Journal of Orthodonticsinstname:Dental Press International (DPI)instacron:DPI10.1590/2177-6709.22.1.057-064.oarinfo:eu-repo/semantics/openAccessSchwertner,AlessandroAlmeida,Renato Rodrigues deGonini Jr,AlcidesAlmeida,Marcio Rodrigues deeng2017-04-12T00:00:00Zoai:scielo:S2176-94512017000100057Revistahttp://www.scielo.br/dpjoONGhttps://old.scielo.br/oai/scielo-oai.phpartigos@dentalpress.com.br||davidnormando@hotmail.com2177-67092176-9451opendoar:2017-04-12T00:00Dental Press Journal of Orthodontics - Dental Press International (DPI)false
dc.title.none.fl_str_mv Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA)
title Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA)
spellingShingle Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA)
Schwertner,Alessandro
Intrusion arch
Photoelasticity
Physical properties.
title_short Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA)
title_full Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA)
title_fullStr Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA)
title_full_unstemmed Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA)
title_sort Photoelastic analysis of stress generated by Connecticut Intrusion Arch (CIA)
author Schwertner,Alessandro
author_facet Schwertner,Alessandro
Almeida,Renato Rodrigues de
Gonini Jr,Alcides
Almeida,Marcio Rodrigues de
author_role author
author2 Almeida,Renato Rodrigues de
Gonini Jr,Alcides
Almeida,Marcio Rodrigues de
author2_role author
author
author
dc.contributor.author.fl_str_mv Schwertner,Alessandro
Almeida,Renato Rodrigues de
Gonini Jr,Alcides
Almeida,Marcio Rodrigues de
dc.subject.por.fl_str_mv Intrusion arch
Photoelasticity
Physical properties.
topic Intrusion arch
Photoelasticity
Physical properties.
description ABSTRACT Objective: The present in vitro study evaluated, by means of the photoelastic technique, the effects generated by the Connecticut Intrusion Arch (CIA), with a 90o bend on the distal surface of molar tubes and using the 4 x 2 appliance on the anterior and posterior regions of the upper dental arch. Methods: Five models were manufactured, in which two different clinical situations were correlated: 1) use of intrusion arch not cinched back and transpalatal bar for anchorage (Group 1); 2) use of intrusion arch cinched back and transpalatal bar for anchorage (Group 2). Stress generated in the apical and middle regions of tooth roots of maxillary anterior teeth and maxillary first molars was evaluated. Results: Taking a reference value of 1.0 MPa = 100%, qualitative descriptive analysis was performed, which showed uniformity between stress values in the apical region of anterior teeth of both groups (G1 and G2). In the posterior region, for models with the arch cinched back (G2), stress remained within 100%. As for G1 models (with the arch not cinched back), variations in the mesial surface of first molars were observed, with an increase of 20% in the generated stress. The apical region did not undergo any changes, while in the distal region of molars there was a decrease of 20% in stress. Conclusion: Laboratory results revealed differences in stress between Groups 1 and 2 in the molar region, thereby indicating that there was a tendency towards mesial root tipping of first molars when the distal end of the CIA was not cinched back.
publishDate 2017
dc.date.none.fl_str_mv 2017-02-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512017000100057
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512017000100057
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/2177-6709.22.1.057-064.oar
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Dental Press International
publisher.none.fl_str_mv Dental Press International
dc.source.none.fl_str_mv Dental Press Journal of Orthodontics v.22 n.1 2017
reponame:Dental Press Journal of Orthodontics
instname:Dental Press International (DPI)
instacron:DPI
instname_str Dental Press International (DPI)
instacron_str DPI
institution DPI
reponame_str Dental Press Journal of Orthodontics
collection Dental Press Journal of Orthodontics
repository.name.fl_str_mv Dental Press Journal of Orthodontics - Dental Press International (DPI)
repository.mail.fl_str_mv artigos@dentalpress.com.br||davidnormando@hotmail.com
_version_ 1754122397711073280