Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs

Detalhes bibliográficos
Autor(a) principal: Silva,Elzivânia G.
Data de Publicação: 2018
Outros Autores: Pessoa,Gerson T., Moura,Laecio S., Guerra,Porfírio C., Rodrigues,Renan P.S., Sousa,Francisco C.A., Ambrósio,Carlos E., Alves,Flávio R.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Pesquisa Veterinária Brasileira (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-736X2018000300565
Resumo: ABSTRACT: B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies.
id EMBRAPA-2_23ccbc3da26ef6047797cfa4badea2d8
oai_identifier_str oai:scielo:S0100-736X2018000300565
network_acronym_str EMBRAPA-2
network_name_str Pesquisa Veterinária Brasileira (Online)
repository_id_str
spelling Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogsBiometryB-modeDoppler ultrasounddogseyeballDoppler velocimetryhemodynamicsophthalmologyABSTRACT: B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies.Colégio Brasileiro de Patologia Animal - CBPA2018-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-736X2018000300565Pesquisa Veterinária Brasileira v.38 n.3 2018reponame:Pesquisa Veterinária Brasileira (Online)instname:Colégio Brasileiro de Patologia Animal (CBPA)instacron:EMBRAPA10.1590/1678-5150-pvb-5242info:eu-repo/semantics/openAccessSilva,Elzivânia G.Pessoa,Gerson T.Moura,Laecio S.Guerra,Porfírio C.Rodrigues,Renan P.S.Sousa,Francisco C.A.Ambrósio,Carlos E.Alves,Flávio R.eng2018-06-06T00:00:00Zoai:scielo:S0100-736X2018000300565Revistahttp://www.pvb.com.br/https://old.scielo.br/oai/scielo-oai.phpcolegio@cbpa.org.br||pvb@pvb.com.br0100-736X1678-5150opendoar:2018-06-06T00:00Pesquisa Veterinária Brasileira (Online) - Colégio Brasileiro de Patologia Animal (CBPA)false
dc.title.none.fl_str_mv Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs
title Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs
spellingShingle Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs
Silva,Elzivânia G.
Biometry
B-mode
Doppler ultrasound
dogs
eyeball
Doppler velocimetry
hemodynamics
ophthalmology
title_short Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs
title_full Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs
title_fullStr Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs
title_full_unstemmed Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs
title_sort Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs
author Silva,Elzivânia G.
author_facet Silva,Elzivânia G.
Pessoa,Gerson T.
Moura,Laecio S.
Guerra,Porfírio C.
Rodrigues,Renan P.S.
Sousa,Francisco C.A.
Ambrósio,Carlos E.
Alves,Flávio R.
author_role author
author2 Pessoa,Gerson T.
Moura,Laecio S.
Guerra,Porfírio C.
Rodrigues,Renan P.S.
Sousa,Francisco C.A.
Ambrósio,Carlos E.
Alves,Flávio R.
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Silva,Elzivânia G.
Pessoa,Gerson T.
Moura,Laecio S.
Guerra,Porfírio C.
Rodrigues,Renan P.S.
Sousa,Francisco C.A.
Ambrósio,Carlos E.
Alves,Flávio R.
dc.subject.por.fl_str_mv Biometry
B-mode
Doppler ultrasound
dogs
eyeball
Doppler velocimetry
hemodynamics
ophthalmology
topic Biometry
B-mode
Doppler ultrasound
dogs
eyeball
Doppler velocimetry
hemodynamics
ophthalmology
description ABSTRACT: B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies.
publishDate 2018
dc.date.none.fl_str_mv 2018-03-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-736X2018000300565
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-736X2018000300565
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1678-5150-pvb-5242
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Colégio Brasileiro de Patologia Animal - CBPA
publisher.none.fl_str_mv Colégio Brasileiro de Patologia Animal - CBPA
dc.source.none.fl_str_mv Pesquisa Veterinária Brasileira v.38 n.3 2018
reponame:Pesquisa Veterinária Brasileira (Online)
instname:Colégio Brasileiro de Patologia Animal (CBPA)
instacron:EMBRAPA
instname_str Colégio Brasileiro de Patologia Animal (CBPA)
instacron_str EMBRAPA
institution EMBRAPA
reponame_str Pesquisa Veterinária Brasileira (Online)
collection Pesquisa Veterinária Brasileira (Online)
repository.name.fl_str_mv Pesquisa Veterinária Brasileira (Online) - Colégio Brasileiro de Patologia Animal (CBPA)
repository.mail.fl_str_mv colegio@cbpa.org.br||pvb@pvb.com.br
_version_ 1754122238332764160