Comparison of Two- and Three-dimensional Ultrasonography in the Evaluation of Lesion Level in Fetuses with Spina Bifida
Autor(a) principal: | |
---|---|
Data de Publicação: | 2016 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista brasileira de ginecologia e obstetrícia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032016000300120 |
Resumo: | Purpose To evaluate the precision of both two- and three-dimensional ultrasonography in determining vertebral lesion level (the first open vertebra) in patients with spina bifida. Methods This was a prospective longitudinal study comprising of fetuses with open spina bifida who were treated in the fetal medicine division of the department of obstetrics of Hospital das Clínicas of the Universidade de São Paulo between 2004 and 2013. Vertebral lesion level was established by using both two- and three-dimensional ultrasonography in 50 fetuses (two examiners in each method). The lesion level in the neonatal period was established by radiological assessment of the spine. All pregnancies were followed in our hospital prenatally, and delivery was scheduled to allow immediate postnatal surgical correction. Results Two-dimensional sonography precisely estimated the spina bifida level in 53% of the cases. The estimate error was within one vertebra in 80% of the cases, in up to two vertebrae in 89%, and in up to three vertebrae in 100%, showing a good interobserver agreement. Three-dimensional ultrasonography precisely estimated the lesion level in 50% of the cases. The estimate error was within one vertebra in 82% of the cases, in up to two vertebrae in 90%, and in up to three vertebrae in 100%, also showing good interobserver agreement. Whenever an estimate error was observed, both two- and three-dimensional ultrasonography scans tended to underestimate the true lesion level (55.3% and 62% of the cases, respectively). Conclusions No relevant difference in diagnostic performance was observed between the two- and three-dimensional ultrasonography. The use of three-dimensional ultrasonography showed no additional benefit in diagnosing the lesion level in the fetuses with spina bifida. Errors in both methods showed a tendency to underestimate lesion level. |
id |
FEBRASGO-1_83642629c0a9aedfbfde2ef5ae4449fc |
---|---|
oai_identifier_str |
oai:scielo:S0100-72032016000300120 |
network_acronym_str |
FEBRASGO-1 |
network_name_str |
Revista brasileira de ginecologia e obstetrícia (Online) |
repository_id_str |
|
spelling |
Comparison of Two- and Three-dimensional Ultrasonography in the Evaluation of Lesion Level in Fetuses with Spina Bifidafetustwo-dimensional ultrasonographythree-dimensional ultrasonographyspina bifida Purpose To evaluate the precision of both two- and three-dimensional ultrasonography in determining vertebral lesion level (the first open vertebra) in patients with spina bifida. Methods This was a prospective longitudinal study comprising of fetuses with open spina bifida who were treated in the fetal medicine division of the department of obstetrics of Hospital das Clínicas of the Universidade de São Paulo between 2004 and 2013. Vertebral lesion level was established by using both two- and three-dimensional ultrasonography in 50 fetuses (two examiners in each method). The lesion level in the neonatal period was established by radiological assessment of the spine. All pregnancies were followed in our hospital prenatally, and delivery was scheduled to allow immediate postnatal surgical correction. Results Two-dimensional sonography precisely estimated the spina bifida level in 53% of the cases. The estimate error was within one vertebra in 80% of the cases, in up to two vertebrae in 89%, and in up to three vertebrae in 100%, showing a good interobserver agreement. Three-dimensional ultrasonography precisely estimated the lesion level in 50% of the cases. The estimate error was within one vertebra in 82% of the cases, in up to two vertebrae in 90%, and in up to three vertebrae in 100%, also showing good interobserver agreement. Whenever an estimate error was observed, both two- and three-dimensional ultrasonography scans tended to underestimate the true lesion level (55.3% and 62% of the cases, respectively). Conclusions No relevant difference in diagnostic performance was observed between the two- and three-dimensional ultrasonography. The use of three-dimensional ultrasonography showed no additional benefit in diagnosing the lesion level in the fetuses with spina bifida. Errors in both methods showed a tendency to underestimate lesion level.Federação Brasileira das Sociedades de Ginecologia e Obstetrícia2016-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032016000300120Revista Brasileira de Ginecologia e Obstetrícia v.38 n.3 2016reponame:Revista brasileira de ginecologia e obstetrícia (Online)instname:Federação Brasileira das Sociedades de Ginecologia e Obstetrícia (FEBRASGO)instacron:FEBRASGO10.1055/s-0036-1580711info:eu-repo/semantics/openAccessRequeijo,Márcio José RosaBunduki,VictorFrancisco,Rossana Pulcineli VieiraLopes,Marco Antonio BorgesRuano,RodrigoZugaib,Marceloeng2016-05-05T00:00:00Zoai:scielo:S0100-72032016000300120Revistahttp://www.scielo.br/rbgohttps://old.scielo.br/oai/scielo-oai.phppublicações@febrasgo.org.br||rbgo@fmrp.usp.br1806-93390100-7203opendoar:2016-05-05T00:00Revista brasileira de ginecologia e obstetrícia (Online) - Federação Brasileira das Sociedades de Ginecologia e Obstetrícia (FEBRASGO)false |
dc.title.none.fl_str_mv |
Comparison of Two- and Three-dimensional Ultrasonography in the Evaluation of Lesion Level in Fetuses with Spina Bifida |
title |
Comparison of Two- and Three-dimensional Ultrasonography in the Evaluation of Lesion Level in Fetuses with Spina Bifida |
spellingShingle |
Comparison of Two- and Three-dimensional Ultrasonography in the Evaluation of Lesion Level in Fetuses with Spina Bifida Requeijo,Márcio José Rosa fetus two-dimensional ultrasonography three-dimensional ultrasonography spina bifida |
title_short |
Comparison of Two- and Three-dimensional Ultrasonography in the Evaluation of Lesion Level in Fetuses with Spina Bifida |
title_full |
Comparison of Two- and Three-dimensional Ultrasonography in the Evaluation of Lesion Level in Fetuses with Spina Bifida |
title_fullStr |
Comparison of Two- and Three-dimensional Ultrasonography in the Evaluation of Lesion Level in Fetuses with Spina Bifida |
title_full_unstemmed |
Comparison of Two- and Three-dimensional Ultrasonography in the Evaluation of Lesion Level in Fetuses with Spina Bifida |
title_sort |
Comparison of Two- and Three-dimensional Ultrasonography in the Evaluation of Lesion Level in Fetuses with Spina Bifida |
author |
Requeijo,Márcio José Rosa |
author_facet |
Requeijo,Márcio José Rosa Bunduki,Victor Francisco,Rossana Pulcineli Vieira Lopes,Marco Antonio Borges Ruano,Rodrigo Zugaib,Marcelo |
author_role |
author |
author2 |
Bunduki,Victor Francisco,Rossana Pulcineli Vieira Lopes,Marco Antonio Borges Ruano,Rodrigo Zugaib,Marcelo |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Requeijo,Márcio José Rosa Bunduki,Victor Francisco,Rossana Pulcineli Vieira Lopes,Marco Antonio Borges Ruano,Rodrigo Zugaib,Marcelo |
dc.subject.por.fl_str_mv |
fetus two-dimensional ultrasonography three-dimensional ultrasonography spina bifida |
topic |
fetus two-dimensional ultrasonography three-dimensional ultrasonography spina bifida |
description |
Purpose To evaluate the precision of both two- and three-dimensional ultrasonography in determining vertebral lesion level (the first open vertebra) in patients with spina bifida. Methods This was a prospective longitudinal study comprising of fetuses with open spina bifida who were treated in the fetal medicine division of the department of obstetrics of Hospital das Clínicas of the Universidade de São Paulo between 2004 and 2013. Vertebral lesion level was established by using both two- and three-dimensional ultrasonography in 50 fetuses (two examiners in each method). The lesion level in the neonatal period was established by radiological assessment of the spine. All pregnancies were followed in our hospital prenatally, and delivery was scheduled to allow immediate postnatal surgical correction. Results Two-dimensional sonography precisely estimated the spina bifida level in 53% of the cases. The estimate error was within one vertebra in 80% of the cases, in up to two vertebrae in 89%, and in up to three vertebrae in 100%, showing a good interobserver agreement. Three-dimensional ultrasonography precisely estimated the lesion level in 50% of the cases. The estimate error was within one vertebra in 82% of the cases, in up to two vertebrae in 90%, and in up to three vertebrae in 100%, also showing good interobserver agreement. Whenever an estimate error was observed, both two- and three-dimensional ultrasonography scans tended to underestimate the true lesion level (55.3% and 62% of the cases, respectively). Conclusions No relevant difference in diagnostic performance was observed between the two- and three-dimensional ultrasonography. The use of three-dimensional ultrasonography showed no additional benefit in diagnosing the lesion level in the fetuses with spina bifida. Errors in both methods showed a tendency to underestimate lesion level. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-03-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032016000300120 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032016000300120 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1055/s-0036-1580711 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia |
publisher.none.fl_str_mv |
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia |
dc.source.none.fl_str_mv |
Revista Brasileira de Ginecologia e Obstetrícia v.38 n.3 2016 reponame:Revista brasileira de ginecologia e obstetrícia (Online) instname:Federação Brasileira das Sociedades de Ginecologia e Obstetrícia (FEBRASGO) instacron:FEBRASGO |
instname_str |
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia (FEBRASGO) |
instacron_str |
FEBRASGO |
institution |
FEBRASGO |
reponame_str |
Revista brasileira de ginecologia e obstetrícia (Online) |
collection |
Revista brasileira de ginecologia e obstetrícia (Online) |
repository.name.fl_str_mv |
Revista brasileira de ginecologia e obstetrícia (Online) - Federação Brasileira das Sociedades de Ginecologia e Obstetrícia (FEBRASGO) |
repository.mail.fl_str_mv |
publicações@febrasgo.org.br||rbgo@fmrp.usp.br |
_version_ |
1754115943198359552 |