Qualitative Determination of Human Chorionic Gonadotropin in Vaginal Washings for the Early Diagnosis of Premature Rupture of Fetal Membranes
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista brasileira de ginecologia e obstetrícia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032017000700317 |
Resumo: | Abstract Purpose This study aimed to evaluate and validate the qualitative human chorionic gonadotropin β subunit (β-hCG) test of the vaginal fluid washings of pregnant women with premature rupture of fetal membranes (PROM). Methods Cross-sectional study of pregnant women between gestational weeks 24 and 39 who underwent consultations in one of our institutions. They were divided into two groups: group A (pregnant women clinically diagnosed with PROM) and group B (pregnant women without loss of amniotic liquid). The patients were subjected to a vaginal fluid washing with 3 mL of saline solution, which was aspirated subsequently with the same syringe. The solution was immediately sent to the laboratory to perform the vaginal β-hCG test with cut-off points of 10 mIU/mL (β-hCG-10) and/or 25 mIU/mL (β-hCG-25). Results The β-hCG-10 test of the vaginal secretion was performed in 128 cases. The chi-squared test with Yates’ correction showed a statistically significant difference between the 2 groups (p = 0.0225). The sensibility, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy parameters were 77.1%, 43.6%, 52.3%; 70.4%; and 58.6% respectively. The β-hCG-25 test of the vaginal washing was performed in 49 cases. The analysis by Fisher’s exact test showed a statistically significant difference between the groups (p = 0.0175). The sensibility, specificity, PPV, NPV, and accuracy parameters were 44.4%, 87.1%, 66.6%; 72.9%; and 71.4% respectively. Conclusions The β-hCG-25 test showed better accuracy for the diagnosis of PROM, and can corroborate the early diagnosis of PROM because it is a simple and quick exam. |
id |
FEBRASGO-1_d98eab7ed74119749a96472fbf46688f |
---|---|
oai_identifier_str |
oai:scielo:S0100-72032017000700317 |
network_acronym_str |
FEBRASGO-1 |
network_name_str |
Revista brasileira de ginecologia e obstetrícia (Online) |
repository_id_str |
|
spelling |
Qualitative Determination of Human Chorionic Gonadotropin in Vaginal Washings for the Early Diagnosis of Premature Rupture of Fetal Membraneshuman chorionic gonadotropinβ subunitpremature rupture of fetal membranesdiagnosisobstetricspregnancy complicationsAbstract Purpose This study aimed to evaluate and validate the qualitative human chorionic gonadotropin β subunit (β-hCG) test of the vaginal fluid washings of pregnant women with premature rupture of fetal membranes (PROM). Methods Cross-sectional study of pregnant women between gestational weeks 24 and 39 who underwent consultations in one of our institutions. They were divided into two groups: group A (pregnant women clinically diagnosed with PROM) and group B (pregnant women without loss of amniotic liquid). The patients were subjected to a vaginal fluid washing with 3 mL of saline solution, which was aspirated subsequently with the same syringe. The solution was immediately sent to the laboratory to perform the vaginal β-hCG test with cut-off points of 10 mIU/mL (β-hCG-10) and/or 25 mIU/mL (β-hCG-25). Results The β-hCG-10 test of the vaginal secretion was performed in 128 cases. The chi-squared test with Yates’ correction showed a statistically significant difference between the 2 groups (p = 0.0225). The sensibility, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy parameters were 77.1%, 43.6%, 52.3%; 70.4%; and 58.6% respectively. The β-hCG-25 test of the vaginal washing was performed in 49 cases. The analysis by Fisher’s exact test showed a statistically significant difference between the groups (p = 0.0175). The sensibility, specificity, PPV, NPV, and accuracy parameters were 44.4%, 87.1%, 66.6%; 72.9%; and 71.4% respectively. Conclusions The β-hCG-25 test showed better accuracy for the diagnosis of PROM, and can corroborate the early diagnosis of PROM because it is a simple and quick exam.Federação Brasileira das Sociedades de Ginecologia e Obstetrícia2017-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032017000700317Revista Brasileira de Ginecologia e Obstetrícia v.39 n.7 2017reponame:Revista brasileira de ginecologia e obstetrícia (Online)instname:Federação Brasileira das Sociedades de Ginecologia e Obstetrícia (FEBRASGO)instacron:FEBRASGO10.1055/s-0037-1603939info:eu-repo/semantics/openAccessDartibale,Camila BuziquiaUchimura,Nelson ShozoNery,LuizSchumeish,Angelita PolatoUchimura,Liza Yurie TeruyaSantana,Rosangela GetiranaUchimura,Taqueco Teruyaeng2017-08-18T00:00:00Zoai:scielo:S0100-72032017000700317Revistahttp://www.scielo.br/rbgohttps://old.scielo.br/oai/scielo-oai.phppublicações@febrasgo.org.br||rbgo@fmrp.usp.br1806-93390100-7203opendoar:2017-08-18T00:00Revista brasileira de ginecologia e obstetrícia (Online) - Federação Brasileira das Sociedades de Ginecologia e Obstetrícia (FEBRASGO)false |
dc.title.none.fl_str_mv |
Qualitative Determination of Human Chorionic Gonadotropin in Vaginal Washings for the Early Diagnosis of Premature Rupture of Fetal Membranes |
title |
Qualitative Determination of Human Chorionic Gonadotropin in Vaginal Washings for the Early Diagnosis of Premature Rupture of Fetal Membranes |
spellingShingle |
Qualitative Determination of Human Chorionic Gonadotropin in Vaginal Washings for the Early Diagnosis of Premature Rupture of Fetal Membranes Dartibale,Camila Buziquia human chorionic gonadotropin β subunit premature rupture of fetal membranes diagnosis obstetrics pregnancy complications |
title_short |
Qualitative Determination of Human Chorionic Gonadotropin in Vaginal Washings for the Early Diagnosis of Premature Rupture of Fetal Membranes |
title_full |
Qualitative Determination of Human Chorionic Gonadotropin in Vaginal Washings for the Early Diagnosis of Premature Rupture of Fetal Membranes |
title_fullStr |
Qualitative Determination of Human Chorionic Gonadotropin in Vaginal Washings for the Early Diagnosis of Premature Rupture of Fetal Membranes |
title_full_unstemmed |
Qualitative Determination of Human Chorionic Gonadotropin in Vaginal Washings for the Early Diagnosis of Premature Rupture of Fetal Membranes |
title_sort |
Qualitative Determination of Human Chorionic Gonadotropin in Vaginal Washings for the Early Diagnosis of Premature Rupture of Fetal Membranes |
author |
Dartibale,Camila Buziquia |
author_facet |
Dartibale,Camila Buziquia Uchimura,Nelson Shozo Nery,Luiz Schumeish,Angelita Polato Uchimura,Liza Yurie Teruya Santana,Rosangela Getirana Uchimura,Taqueco Teruya |
author_role |
author |
author2 |
Uchimura,Nelson Shozo Nery,Luiz Schumeish,Angelita Polato Uchimura,Liza Yurie Teruya Santana,Rosangela Getirana Uchimura,Taqueco Teruya |
author2_role |
author author author author author author |
dc.contributor.author.fl_str_mv |
Dartibale,Camila Buziquia Uchimura,Nelson Shozo Nery,Luiz Schumeish,Angelita Polato Uchimura,Liza Yurie Teruya Santana,Rosangela Getirana Uchimura,Taqueco Teruya |
dc.subject.por.fl_str_mv |
human chorionic gonadotropin β subunit premature rupture of fetal membranes diagnosis obstetrics pregnancy complications |
topic |
human chorionic gonadotropin β subunit premature rupture of fetal membranes diagnosis obstetrics pregnancy complications |
description |
Abstract Purpose This study aimed to evaluate and validate the qualitative human chorionic gonadotropin β subunit (β-hCG) test of the vaginal fluid washings of pregnant women with premature rupture of fetal membranes (PROM). Methods Cross-sectional study of pregnant women between gestational weeks 24 and 39 who underwent consultations in one of our institutions. They were divided into two groups: group A (pregnant women clinically diagnosed with PROM) and group B (pregnant women without loss of amniotic liquid). The patients were subjected to a vaginal fluid washing with 3 mL of saline solution, which was aspirated subsequently with the same syringe. The solution was immediately sent to the laboratory to perform the vaginal β-hCG test with cut-off points of 10 mIU/mL (β-hCG-10) and/or 25 mIU/mL (β-hCG-25). Results The β-hCG-10 test of the vaginal secretion was performed in 128 cases. The chi-squared test with Yates’ correction showed a statistically significant difference between the 2 groups (p = 0.0225). The sensibility, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy parameters were 77.1%, 43.6%, 52.3%; 70.4%; and 58.6% respectively. The β-hCG-25 test of the vaginal washing was performed in 49 cases. The analysis by Fisher’s exact test showed a statistically significant difference between the groups (p = 0.0175). The sensibility, specificity, PPV, NPV, and accuracy parameters were 44.4%, 87.1%, 66.6%; 72.9%; and 71.4% respectively. Conclusions The β-hCG-25 test showed better accuracy for the diagnosis of PROM, and can corroborate the early diagnosis of PROM because it is a simple and quick exam. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-07-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032017000700317 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-72032017000700317 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1055/s-0037-1603939 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia |
publisher.none.fl_str_mv |
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia |
dc.source.none.fl_str_mv |
Revista Brasileira de Ginecologia e Obstetrícia v.39 n.7 2017 reponame:Revista brasileira de ginecologia e obstetrícia (Online) instname:Federação Brasileira das Sociedades de Ginecologia e Obstetrícia (FEBRASGO) instacron:FEBRASGO |
instname_str |
Federação Brasileira das Sociedades de Ginecologia e Obstetrícia (FEBRASGO) |
instacron_str |
FEBRASGO |
institution |
FEBRASGO |
reponame_str |
Revista brasileira de ginecologia e obstetrícia (Online) |
collection |
Revista brasileira de ginecologia e obstetrícia (Online) |
repository.name.fl_str_mv |
Revista brasileira de ginecologia e obstetrícia (Online) - Federação Brasileira das Sociedades de Ginecologia e Obstetrícia (FEBRASGO) |
repository.mail.fl_str_mv |
publicações@febrasgo.org.br||rbgo@fmrp.usp.br |
_version_ |
1754115943917682688 |