Experimental analysis of built-up cold-formed steel lipped channel stub column

Detalhes bibliográficos
Autor(a) principal: Bastos,Cristiane Cruxen Daemon d´Oliveira
Data de Publicação: 2019
Outros Autores: Batista,Eduardo de Miranda
Tipo de documento: Artigo
Idioma: eng
Título da fonte: REM - International Engineering Journal
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2448-167X2019000500571
Resumo: Abstract This article reports the results of experimental tests conducted on built-up cold-formed steel (CFS) stub columns, composed of double lipped channel members connected with self-drilling screws, which will be applied as the chord members of laced columns. These experiments aim to quantify the effect of four distinct web fastener layouts on the composite action, including the ultimate strength, buckling modes and collapse mechanism for built-up CFS members. The tested stub columns are of 480mm length, double 88x86x40x42x12mm lipped channel cross-section and 0.8mm thickness. The built-up CFS lipped channel members were analyzed with help of the Generalized Beam Theory in order to identify their buckling loads and modes. The Direct Strength Method (DSM) was adopted to obtain the analytical strength of the built-up members, to be compared with the experimental results. The axially compressed built-up members displayed local and distortional buckling, negligible composite behavior and minor effect of number and distribution of the screws. The results indicate (i) inefficient behavior of the self-drilling screws for composite condition purposes and (ii) the DSM rules for non-composite CFS are able to estimate the ultimate strength of this type of built-up lipped channel section.
id FG-1_3ec40603935585008f57eee613bbd7a0
oai_identifier_str oai:scielo:S2448-167X2019000500571
network_acronym_str FG-1
network_name_str REM - International Engineering Journal
repository_id_str
spelling Experimental analysis of built-up cold-formed steel lipped channel stub columnbucklingcold formed steelcolumnbuilt-up sectioncompression testsAbstract This article reports the results of experimental tests conducted on built-up cold-formed steel (CFS) stub columns, composed of double lipped channel members connected with self-drilling screws, which will be applied as the chord members of laced columns. These experiments aim to quantify the effect of four distinct web fastener layouts on the composite action, including the ultimate strength, buckling modes and collapse mechanism for built-up CFS members. The tested stub columns are of 480mm length, double 88x86x40x42x12mm lipped channel cross-section and 0.8mm thickness. The built-up CFS lipped channel members were analyzed with help of the Generalized Beam Theory in order to identify their buckling loads and modes. The Direct Strength Method (DSM) was adopted to obtain the analytical strength of the built-up members, to be compared with the experimental results. The axially compressed built-up members displayed local and distortional buckling, negligible composite behavior and minor effect of number and distribution of the screws. The results indicate (i) inefficient behavior of the self-drilling screws for composite condition purposes and (ii) the DSM rules for non-composite CFS are able to estimate the ultimate strength of this type of built-up lipped channel section.Fundação Gorceix2019-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2448-167X2019000500571REM - International Engineering Journal v.72 n.4 2019reponame:REM - International Engineering Journalinstname:Fundação Gorceix (FG)instacron:FG10.1590/0370-44672019720008info:eu-repo/semantics/openAccessBastos,Cristiane Cruxen Daemon d´OliveiraBatista,Eduardo de Mirandaeng2019-09-13T00:00:00Zoai:scielo:S2448-167X2019000500571Revistahttps://www.rem.com.br/?lang=pt-brPRIhttps://old.scielo.br/oai/scielo-oai.php||editor@rem.com.br2448-167X2448-167Xopendoar:2019-09-13T00:00REM - International Engineering Journal - Fundação Gorceix (FG)false
dc.title.none.fl_str_mv Experimental analysis of built-up cold-formed steel lipped channel stub column
title Experimental analysis of built-up cold-formed steel lipped channel stub column
spellingShingle Experimental analysis of built-up cold-formed steel lipped channel stub column
Bastos,Cristiane Cruxen Daemon d´Oliveira
buckling
cold formed steel
column
built-up section
compression tests
title_short Experimental analysis of built-up cold-formed steel lipped channel stub column
title_full Experimental analysis of built-up cold-formed steel lipped channel stub column
title_fullStr Experimental analysis of built-up cold-formed steel lipped channel stub column
title_full_unstemmed Experimental analysis of built-up cold-formed steel lipped channel stub column
title_sort Experimental analysis of built-up cold-formed steel lipped channel stub column
author Bastos,Cristiane Cruxen Daemon d´Oliveira
author_facet Bastos,Cristiane Cruxen Daemon d´Oliveira
Batista,Eduardo de Miranda
author_role author
author2 Batista,Eduardo de Miranda
author2_role author
dc.contributor.author.fl_str_mv Bastos,Cristiane Cruxen Daemon d´Oliveira
Batista,Eduardo de Miranda
dc.subject.por.fl_str_mv buckling
cold formed steel
column
built-up section
compression tests
topic buckling
cold formed steel
column
built-up section
compression tests
description Abstract This article reports the results of experimental tests conducted on built-up cold-formed steel (CFS) stub columns, composed of double lipped channel members connected with self-drilling screws, which will be applied as the chord members of laced columns. These experiments aim to quantify the effect of four distinct web fastener layouts on the composite action, including the ultimate strength, buckling modes and collapse mechanism for built-up CFS members. The tested stub columns are of 480mm length, double 88x86x40x42x12mm lipped channel cross-section and 0.8mm thickness. The built-up CFS lipped channel members were analyzed with help of the Generalized Beam Theory in order to identify their buckling loads and modes. The Direct Strength Method (DSM) was adopted to obtain the analytical strength of the built-up members, to be compared with the experimental results. The axially compressed built-up members displayed local and distortional buckling, negligible composite behavior and minor effect of number and distribution of the screws. The results indicate (i) inefficient behavior of the self-drilling screws for composite condition purposes and (ii) the DSM rules for non-composite CFS are able to estimate the ultimate strength of this type of built-up lipped channel section.
publishDate 2019
dc.date.none.fl_str_mv 2019-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2448-167X2019000500571
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2448-167X2019000500571
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0370-44672019720008
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Gorceix
publisher.none.fl_str_mv Fundação Gorceix
dc.source.none.fl_str_mv REM - International Engineering Journal v.72 n.4 2019
reponame:REM - International Engineering Journal
instname:Fundação Gorceix (FG)
instacron:FG
instname_str Fundação Gorceix (FG)
instacron_str FG
institution FG
reponame_str REM - International Engineering Journal
collection REM - International Engineering Journal
repository.name.fl_str_mv REM - International Engineering Journal - Fundação Gorceix (FG)
repository.mail.fl_str_mv ||editor@rem.com.br
_version_ 1754734691418636288