Automated systems in the identification and determination of methicillin resistance among coagulase negative staphylococci

Detalhes bibliográficos
Autor(a) principal: Caierão,Juliana
Data de Publicação: 2006
Outros Autores: Superti,Silvana, Dias,Cícero AG, d'Azevedo,Pedro Alves
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Memórias do Instituto Oswaldo Cruz
Texto Completo: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762006000300009
Resumo: Coagulase-negative staphylococci (CoNS) are an important cause of nosocomial bacteremia, specially in patients with indwelling devices or those submitted to invasive medical procedures. The identification of species and the accurate and rapid detection of methicillin resistance are directly dependent on the quality of the identification and susceptibility tests used, either manual or automated. The objective of this study was to evaluate the accuracy of two automated systems MicroScan and Vitek - in the identification of CoNS species and determination of susceptibility to methicillin, considering as gold standard the biochemical tests and the characterization of the mecA gene by polymerase chain reaction, respectively. MicroScan presented better results in the identification of CoNS species (accuracy of 96.8 vs 78.8%, respectively); isolates from the following species had no precise identification: Staphylococcus haemolyticus, S. simulans, and S. capitis. Both systems were similar in the characterization of methicillin resistance. The higher discrepancies for gene mec detection were observed among species other than S. epidermidis (S. hominis, S. saprophyticus, S. sciuri, S. haemolyticus, S. warneri, S. cohnii), and those with borderline MICs.
id FIOCRUZ-4_43d9ebcbc528eab854f989c0215e06aa
oai_identifier_str oai:scielo:S0074-02762006000300009
network_acronym_str FIOCRUZ-4
network_name_str Memórias do Instituto Oswaldo Cruz
spelling Automated systems in the identification and determination of methicillin resistance among coagulase negative staphylococcicoagulase-negative staphylococcimethicillinautomated systemsCoagulase-negative staphylococci (CoNS) are an important cause of nosocomial bacteremia, specially in patients with indwelling devices or those submitted to invasive medical procedures. The identification of species and the accurate and rapid detection of methicillin resistance are directly dependent on the quality of the identification and susceptibility tests used, either manual or automated. The objective of this study was to evaluate the accuracy of two automated systems MicroScan and Vitek - in the identification of CoNS species and determination of susceptibility to methicillin, considering as gold standard the biochemical tests and the characterization of the mecA gene by polymerase chain reaction, respectively. MicroScan presented better results in the identification of CoNS species (accuracy of 96.8 vs 78.8%, respectively); isolates from the following species had no precise identification: Staphylococcus haemolyticus, S. simulans, and S. capitis. Both systems were similar in the characterization of methicillin resistance. The higher discrepancies for gene mec detection were observed among species other than S. epidermidis (S. hominis, S. saprophyticus, S. sciuri, S. haemolyticus, S. warneri, S. cohnii), and those with borderline MICs.Instituto Oswaldo Cruz, Ministério da Saúde2006-05-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762006000300009Memórias do Instituto Oswaldo Cruz v.101 n.3 2006reponame:Memórias do Instituto Oswaldo Cruzinstname:Fundação Oswaldo Cruzinstacron:FIOCRUZ10.1590/S0074-02762006000300009info:eu-repo/semantics/openAccessCaierão,JulianaSuperti,SilvanaDias,Cícero AGd'Azevedo,Pedro Alveseng2020-04-25T17:49:34Zhttp://www.scielo.br/oai/scielo-oai.php0074-02761678-8060opendoar:null2020-04-26 02:13:45.546Memórias do Instituto Oswaldo Cruz - Fundação Oswaldo Cruztrue
dc.title.none.fl_str_mv Automated systems in the identification and determination of methicillin resistance among coagulase negative staphylococci
title Automated systems in the identification and determination of methicillin resistance among coagulase negative staphylococci
spellingShingle Automated systems in the identification and determination of methicillin resistance among coagulase negative staphylococci
Caierão,Juliana
coagulase-negative staphylococci
methicillin
automated systems
title_short Automated systems in the identification and determination of methicillin resistance among coagulase negative staphylococci
title_full Automated systems in the identification and determination of methicillin resistance among coagulase negative staphylococci
title_fullStr Automated systems in the identification and determination of methicillin resistance among coagulase negative staphylococci
title_full_unstemmed Automated systems in the identification and determination of methicillin resistance among coagulase negative staphylococci
title_sort Automated systems in the identification and determination of methicillin resistance among coagulase negative staphylococci
author Caierão,Juliana
author_facet Caierão,Juliana
Superti,Silvana
Dias,Cícero AG
d'Azevedo,Pedro Alves
author_role author
author2 Superti,Silvana
Dias,Cícero AG
d'Azevedo,Pedro Alves
author2_role author
author
author
dc.contributor.author.fl_str_mv Caierão,Juliana
Superti,Silvana
Dias,Cícero AG
d'Azevedo,Pedro Alves
dc.subject.por.fl_str_mv coagulase-negative staphylococci
methicillin
automated systems
topic coagulase-negative staphylococci
methicillin
automated systems
dc.description.none.fl_txt_mv Coagulase-negative staphylococci (CoNS) are an important cause of nosocomial bacteremia, specially in patients with indwelling devices or those submitted to invasive medical procedures. The identification of species and the accurate and rapid detection of methicillin resistance are directly dependent on the quality of the identification and susceptibility tests used, either manual or automated. The objective of this study was to evaluate the accuracy of two automated systems MicroScan and Vitek - in the identification of CoNS species and determination of susceptibility to methicillin, considering as gold standard the biochemical tests and the characterization of the mecA gene by polymerase chain reaction, respectively. MicroScan presented better results in the identification of CoNS species (accuracy of 96.8 vs 78.8%, respectively); isolates from the following species had no precise identification: Staphylococcus haemolyticus, S. simulans, and S. capitis. Both systems were similar in the characterization of methicillin resistance. The higher discrepancies for gene mec detection were observed among species other than S. epidermidis (S. hominis, S. saprophyticus, S. sciuri, S. haemolyticus, S. warneri, S. cohnii), and those with borderline MICs.
description Coagulase-negative staphylococci (CoNS) are an important cause of nosocomial bacteremia, specially in patients with indwelling devices or those submitted to invasive medical procedures. The identification of species and the accurate and rapid detection of methicillin resistance are directly dependent on the quality of the identification and susceptibility tests used, either manual or automated. The objective of this study was to evaluate the accuracy of two automated systems MicroScan and Vitek - in the identification of CoNS species and determination of susceptibility to methicillin, considering as gold standard the biochemical tests and the characterization of the mecA gene by polymerase chain reaction, respectively. MicroScan presented better results in the identification of CoNS species (accuracy of 96.8 vs 78.8%, respectively); isolates from the following species had no precise identification: Staphylococcus haemolyticus, S. simulans, and S. capitis. Both systems were similar in the characterization of methicillin resistance. The higher discrepancies for gene mec detection were observed among species other than S. epidermidis (S. hominis, S. saprophyticus, S. sciuri, S. haemolyticus, S. warneri, S. cohnii), and those with borderline MICs.
publishDate 2006
dc.date.none.fl_str_mv 2006-05-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762006000300009
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762006000300009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0074-02762006000300009
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto Oswaldo Cruz, Ministério da Saúde
publisher.none.fl_str_mv Instituto Oswaldo Cruz, Ministério da Saúde
dc.source.none.fl_str_mv Memórias do Instituto Oswaldo Cruz v.101 n.3 2006
reponame:Memórias do Instituto Oswaldo Cruz
instname:Fundação Oswaldo Cruz
instacron:FIOCRUZ
reponame_str Memórias do Instituto Oswaldo Cruz
collection Memórias do Instituto Oswaldo Cruz
instname_str Fundação Oswaldo Cruz
instacron_str FIOCRUZ
institution FIOCRUZ
repository.name.fl_str_mv Memórias do Instituto Oswaldo Cruz - Fundação Oswaldo Cruz
repository.mail.fl_str_mv
_version_ 1669937695838699520