Resumo: | Immunodetection of human IgG anti-Toxocara canis was developed based on ELISA and on the use of polysiloxane/polyvinyl alcohol (POS/PVA) beads. A recombinant antigen was covalently immobilized, via glutaraldehyde, onto this hybrid inorganic-organic composite, which was prepared by the sol-gel technique. Using only 31.2 ng antigen per bead, a peroxidase conjugate dilution of 1:10,000 and a serum dilution of 1:200 were adequate for the establishment of the procedure. This procedure is comparable to that which utilizes the adsorption of the antigen to conventional PVC plates. However, the difference between positive and negative sera mean absorbances was larger for this new glass based assay. In addition to the performance of the POS/PVA bead as a matrix for immunodetection, its easy synthesis and low cost are additional advantages for commercial application. |
id |
FIOCRUZ-4_c9c1c4180b7e7c9a8f2ff32d811c60e2 |
---|---|
oai_identifier_str |
oai:scielo:S0074-02762003000300018 |
network_acronym_str |
FIOCRUZ-4 |
network_name_str |
Memórias do Instituto Oswaldo Cruz |
spelling |
The ue of polysiloxane/polyvinyl alcohol beads as solid phase in IgG anti-Toxocara canis detection using a recombinant antigenpolysiloxanepolyvinyl alcoholrecombinant antigenToxocara canisImmunodetection of human IgG anti-Toxocara canis was developed based on ELISA and on the use of polysiloxane/polyvinyl alcohol (POS/PVA) beads. A recombinant antigen was covalently immobilized, via glutaraldehyde, onto this hybrid inorganic-organic composite, which was prepared by the sol-gel technique. Using only 31.2 ng antigen per bead, a peroxidase conjugate dilution of 1:10,000 and a serum dilution of 1:200 were adequate for the establishment of the procedure. This procedure is comparable to that which utilizes the adsorption of the antigen to conventional PVC plates. However, the difference between positive and negative sera mean absorbances was larger for this new glass based assay. In addition to the performance of the POS/PVA bead as a matrix for immunodetection, its easy synthesis and low cost are additional advantages for commercial application.Instituto Oswaldo Cruz, Ministério da Saúde2003-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762003000300018Memórias do Instituto Oswaldo Cruz v.98 n.3 2003reponame:Memórias do Instituto Oswaldo Cruzinstname:Fundação Oswaldo Cruzinstacron:FIOCRUZ10.1590/S0074-02762003000300018info:eu-repo/semantics/openAccessCoêlho,Raquel de Andrade LimaYamasaki,HiroshiPerez,EmíliaCarvalho Jr,Luiz Bezerra deeng2020-04-25T17:49:03Zhttp://www.scielo.br/oai/scielo-oai.php0074-02761678-8060opendoar:null2020-04-26 02:11:54.96Memórias do Instituto Oswaldo Cruz - Fundação Oswaldo Cruztrue |
dc.title.none.fl_str_mv |
The ue of polysiloxane/polyvinyl alcohol beads as solid phase in IgG anti-Toxocara canis detection using a recombinant antigen |
title |
The ue of polysiloxane/polyvinyl alcohol beads as solid phase in IgG anti-Toxocara canis detection using a recombinant antigen |
spellingShingle |
The ue of polysiloxane/polyvinyl alcohol beads as solid phase in IgG anti-Toxocara canis detection using a recombinant antigen Coêlho,Raquel de Andrade Lima polysiloxane polyvinyl alcohol recombinant antigen Toxocara canis |
title_short |
The ue of polysiloxane/polyvinyl alcohol beads as solid phase in IgG anti-Toxocara canis detection using a recombinant antigen |
title_full |
The ue of polysiloxane/polyvinyl alcohol beads as solid phase in IgG anti-Toxocara canis detection using a recombinant antigen |
title_fullStr |
The ue of polysiloxane/polyvinyl alcohol beads as solid phase in IgG anti-Toxocara canis detection using a recombinant antigen |
title_full_unstemmed |
The ue of polysiloxane/polyvinyl alcohol beads as solid phase in IgG anti-Toxocara canis detection using a recombinant antigen |
title_sort |
The ue of polysiloxane/polyvinyl alcohol beads as solid phase in IgG anti-Toxocara canis detection using a recombinant antigen |
author |
Coêlho,Raquel de Andrade Lima |
author_facet |
Coêlho,Raquel de Andrade Lima Yamasaki,Hiroshi Perez,Emília Carvalho Jr,Luiz Bezerra de |
author_role |
author |
author2 |
Yamasaki,Hiroshi Perez,Emília Carvalho Jr,Luiz Bezerra de |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Coêlho,Raquel de Andrade Lima Yamasaki,Hiroshi Perez,Emília Carvalho Jr,Luiz Bezerra de |
dc.subject.por.fl_str_mv |
polysiloxane polyvinyl alcohol recombinant antigen Toxocara canis |
topic |
polysiloxane polyvinyl alcohol recombinant antigen Toxocara canis |
dc.description.none.fl_txt_mv |
Immunodetection of human IgG anti-Toxocara canis was developed based on ELISA and on the use of polysiloxane/polyvinyl alcohol (POS/PVA) beads. A recombinant antigen was covalently immobilized, via glutaraldehyde, onto this hybrid inorganic-organic composite, which was prepared by the sol-gel technique. Using only 31.2 ng antigen per bead, a peroxidase conjugate dilution of 1:10,000 and a serum dilution of 1:200 were adequate for the establishment of the procedure. This procedure is comparable to that which utilizes the adsorption of the antigen to conventional PVC plates. However, the difference between positive and negative sera mean absorbances was larger for this new glass based assay. In addition to the performance of the POS/PVA bead as a matrix for immunodetection, its easy synthesis and low cost are additional advantages for commercial application. |
description |
Immunodetection of human IgG anti-Toxocara canis was developed based on ELISA and on the use of polysiloxane/polyvinyl alcohol (POS/PVA) beads. A recombinant antigen was covalently immobilized, via glutaraldehyde, onto this hybrid inorganic-organic composite, which was prepared by the sol-gel technique. Using only 31.2 ng antigen per bead, a peroxidase conjugate dilution of 1:10,000 and a serum dilution of 1:200 were adequate for the establishment of the procedure. This procedure is comparable to that which utilizes the adsorption of the antigen to conventional PVC plates. However, the difference between positive and negative sera mean absorbances was larger for this new glass based assay. In addition to the performance of the POS/PVA bead as a matrix for immunodetection, its easy synthesis and low cost are additional advantages for commercial application. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762003000300018 |
url |
http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762003000300018 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0074-02762003000300018 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto Oswaldo Cruz, Ministério da Saúde |
publisher.none.fl_str_mv |
Instituto Oswaldo Cruz, Ministério da Saúde |
dc.source.none.fl_str_mv |
Memórias do Instituto Oswaldo Cruz v.98 n.3 2003 reponame:Memórias do Instituto Oswaldo Cruz instname:Fundação Oswaldo Cruz instacron:FIOCRUZ |
reponame_str |
Memórias do Instituto Oswaldo Cruz |
collection |
Memórias do Instituto Oswaldo Cruz |
instname_str |
Fundação Oswaldo Cruz |
instacron_str |
FIOCRUZ |
institution |
FIOCRUZ |
repository.name.fl_str_mv |
Memórias do Instituto Oswaldo Cruz - Fundação Oswaldo Cruz |
repository.mail.fl_str_mv |
|
_version_ |
1669937688195629056 |