Diagnostic performance characteristics of rapid dipstick test for Plasmodium vivax malaria

Detalhes bibliográficos
Autor(a) principal: Aslan,Gonul
Data de Publicação: 2001
Outros Autores: Ulukanligil,Mustafa, Seyrek,Adnan, Erel,Ozcan
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Memórias do Instituto Oswaldo Cruz
Texto Completo: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762001000500018
Resumo: We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.
id FIOCRUZ-4_f82ed74a4e80508260ac8e292c05ed56
oai_identifier_str oai:scielo:S0074-02762001000500018
network_acronym_str FIOCRUZ-4
network_name_str Memórias do Instituto Oswaldo Cruz
spelling Diagnostic performance characteristics of rapid dipstick test for Plasmodium vivax malariamalariaPlasmodium vivaxparasite lactate dehydrogenase (pLDH)OptiMAL dipstick testWe compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.Instituto Oswaldo Cruz, Ministério da Saúde2001-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762001000500018Memórias do Instituto Oswaldo Cruz v.96 n.5 2001reponame:Memórias do Instituto Oswaldo Cruzinstname:Fundação Oswaldo Cruzinstacron:FIOCRUZ10.1590/S0074-02762001000500018info:eu-repo/semantics/openAccessAslan,GonulUlukanligil,MustafaSeyrek,AdnanErel,Ozcaneng2020-04-25T17:48:34Zhttp://www.scielo.br/oai/scielo-oai.php0074-02761678-8060opendoar:null2020-04-26 02:10:25.504Memórias do Instituto Oswaldo Cruz - Fundação Oswaldo Cruztrue
dc.title.none.fl_str_mv Diagnostic performance characteristics of rapid dipstick test for Plasmodium vivax malaria
title Diagnostic performance characteristics of rapid dipstick test for Plasmodium vivax malaria
spellingShingle Diagnostic performance characteristics of rapid dipstick test for Plasmodium vivax malaria
Aslan,Gonul
malaria
Plasmodium vivax
parasite lactate dehydrogenase (pLDH)
OptiMAL dipstick test
title_short Diagnostic performance characteristics of rapid dipstick test for Plasmodium vivax malaria
title_full Diagnostic performance characteristics of rapid dipstick test for Plasmodium vivax malaria
title_fullStr Diagnostic performance characteristics of rapid dipstick test for Plasmodium vivax malaria
title_full_unstemmed Diagnostic performance characteristics of rapid dipstick test for Plasmodium vivax malaria
title_sort Diagnostic performance characteristics of rapid dipstick test for Plasmodium vivax malaria
author Aslan,Gonul
author_facet Aslan,Gonul
Ulukanligil,Mustafa
Seyrek,Adnan
Erel,Ozcan
author_role author
author2 Ulukanligil,Mustafa
Seyrek,Adnan
Erel,Ozcan
author2_role author
author
author
dc.contributor.author.fl_str_mv Aslan,Gonul
Ulukanligil,Mustafa
Seyrek,Adnan
Erel,Ozcan
dc.subject.por.fl_str_mv malaria
Plasmodium vivax
parasite lactate dehydrogenase (pLDH)
OptiMAL dipstick test
topic malaria
Plasmodium vivax
parasite lactate dehydrogenase (pLDH)
OptiMAL dipstick test
dc.description.none.fl_txt_mv We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.
description We compared the diagnostic performance characteristics of newly developed method, the rapid dipstick test, which provides colorimetric determination by developing antibody to the lactate dehydrogenase enzyme of parasites, with conventional standard thick-blood film examination. For the rapid test, OptiMAL commercial kits were used. The results were also evaluated with clinical findings from patients. The parasites were determined by microscopic examination of thick-blood films from 81 patients with vivax malaria from southeastern Anatolia, Turkey. The OptiMAL test results were found to be negative in five patients who were diagnosed clinically and through thick-film testing as having vivax malaria. There was no false positivity observed with the OptiMAL test. We concluded that this rapid malaria test has a lower level of sensitivity than the classical thick-blood-film test for malaria, but that these methods have equal specificity.
publishDate 2001
dc.date.none.fl_str_mv 2001-07-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762001000500018
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0074-02762001000500018
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0074-02762001000500018
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto Oswaldo Cruz, Ministério da Saúde
publisher.none.fl_str_mv Instituto Oswaldo Cruz, Ministério da Saúde
dc.source.none.fl_str_mv Memórias do Instituto Oswaldo Cruz v.96 n.5 2001
reponame:Memórias do Instituto Oswaldo Cruz
instname:Fundação Oswaldo Cruz
instacron:FIOCRUZ
reponame_str Memórias do Instituto Oswaldo Cruz
collection Memórias do Instituto Oswaldo Cruz
instname_str Fundação Oswaldo Cruz
instacron_str FIOCRUZ
institution FIOCRUZ
repository.name.fl_str_mv Memórias do Instituto Oswaldo Cruz - Fundação Oswaldo Cruz
repository.mail.fl_str_mv
_version_ 1669937682229231616