Physicochemical Quality Assessment of ultra-Pasteurized Milk Commercially in the City of Erechim-RS

Detalhes bibliográficos
Autor(a) principal: Rosa, Leonardo Souza da
Data de Publicação: 2015
Outros Autores: Garbin, Cassiane Marini, Zamboni, Luana, Bonacina, Marlice Salete
Tipo de documento: Artigo
Idioma: por
Título da fonte: Vigilância Sanitária em Debate
Texto Completo: https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/438
Resumo: This study aimed to commercially evaluate the physicochemical quality of ultra-pasteurized milk in the city of Erechim-RS. In May and August 2014, six samples of whole UHT milk, cor-responding to six different brands, were collected, amounting to 12 samples. The sample’s quality was assessed by analyzing the following parameters: moisture, fat, protein, non-fat solids (NFS), ethanol stability 80%, relative density at 15ºC, acidity, cryoscopic index, and fraud detections by adding starch, formaldehyde, sodium hydroxide, hydrogen peroxide, and antibiotic residues. The measurements of fraud, moisture, NFS, density, acidity, and cryos-copic index were performed in triplicate as Instrução Normative Instruction no. 68/2006.The parameters, fat and protein, were determined in triplicate in an ultrasonic analyzer. The sta-tistical treatment of data was performed according to the Statistical Software 8.0. The results indicated the existence of significant differences (p < 0.05) between brands for the following parameters: moisture, fat, protein, NFS, density, acidity, and cryoscopic index. It was also found that two brands of whole milk UHT evaluated did not meet the minimum quality re-quirements in relation to protein and ESD parameters established by law. Other two brands had indications of tampering by adding starch and sodium hydroxide. From these findings, it was concluded that only two brands met all the minimum quality requirements for UHT milk.
id FIOCRUZ-9_00937918f7ba3cff0035b55b02b22640
oai_identifier_str oai:ojs.visaemdebate.incqs.fiocruz.br:article/438
network_acronym_str FIOCRUZ-9
network_name_str Vigilância Sanitária em Debate
repository_id_str
spelling Physicochemical Quality Assessment of ultra-Pasteurized Milk Commercially in the City of Erechim-RSAvaliação da Qualidade Físico-Química do Leite Ultra Pasteurizado Comercializado no Município de Erechim – RSUHT MilkQualityTamperingPublic HealthLeite UHTQualidadeAdulteraçãoSaúde PúblicaThis study aimed to commercially evaluate the physicochemical quality of ultra-pasteurized milk in the city of Erechim-RS. In May and August 2014, six samples of whole UHT milk, cor-responding to six different brands, were collected, amounting to 12 samples. The sample’s quality was assessed by analyzing the following parameters: moisture, fat, protein, non-fat solids (NFS), ethanol stability 80%, relative density at 15ºC, acidity, cryoscopic index, and fraud detections by adding starch, formaldehyde, sodium hydroxide, hydrogen peroxide, and antibiotic residues. The measurements of fraud, moisture, NFS, density, acidity, and cryos-copic index were performed in triplicate as Instrução Normative Instruction no. 68/2006.The parameters, fat and protein, were determined in triplicate in an ultrasonic analyzer. The sta-tistical treatment of data was performed according to the Statistical Software 8.0. The results indicated the existence of significant differences (p < 0.05) between brands for the following parameters: moisture, fat, protein, NFS, density, acidity, and cryoscopic index. It was also found that two brands of whole milk UHT evaluated did not meet the minimum quality re-quirements in relation to protein and ESD parameters established by law. Other two brands had indications of tampering by adding starch and sodium hydroxide. From these findings, it was concluded that only two brands met all the minimum quality requirements for UHT milk.O trabalho teve como objetivo avaliar a qualidade físico-química do leite ultra pasteurizado comercializado no município de Erechim - RS. Nos meses de maio e agosto de 2014, foram coletadas seis amostras de leite UHT integral, correspondentes a seis diferentes marcas, totalizando doze amostras, cuja qualidade foi avaliada através dos parâmetros umidade, gordura, proteína, extrato seco desengordurado (ESD), estabilidade ao etanol 80%, densidade, acidez, índice crioscópico e detecções de fraudes por adição de amido, formaldeído, hidróxido de sódio, peróxido de hidrogênio e resíduos de antibióticos. As determinações de fraudes, umidade, ESD, densidade, acidez e índice crioscópico foram realizadas em triplicata conforme a Instrução Normativa nº 68, de 12 de dezembro de 2006. Os parâmetros gordura e proteína foram determinados em triplicata em analisador ultrassônico. Os resultados indicaram a existência de diferenças significativas (p < 0,05) entre as diferentes marcas em relação aos parâmetros umidade, gordura, proteína, extrato seco desengordurado, densidade, acidez e índice crioscópico. Constatou-se que duas marcas de leite UHT integral avaliadas não atenderam aos requisitos mínimos de qualidade em relação aos parâmetros ESD e proteína, estabelecido pela legislação. Outras duas marcas evidenciaram indicativos de adulterações por adição de amido e hidróxido de sódio. Mediante os resultados obtidos concluiu-se que apenas duas marcas atenderiam a totalidade dos requisitos mínimos de qualidade do leite UHT.Instituto Nacional de Controle de Qualidade em Saúde2015-05-29info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Peer-reviewed article""Artículo revisado por pares""Artigo avaliado pelos pares"application/pdfapplication/vnd.openxmlformats-officedocument.wordprocessingml.documenthttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/43810.3395/2317-269x.00438Health Surveillance under Debate: Society, Science & Technology ; Vol. 3 No. 2 (2015): May; 99-107Vigilancia en Salud en Debate: Sociedad, Ciencia y Tecnología; Vol. 3 Núm. 2 (2015): Puede; 99-107Vigil Sanit Debate, Rio de Janeiro; v. 3 n. 2 (2015): Maio; 99-1072317-269Xreponame:Vigilância Sanitária em Debateinstname:Fundação Oswaldo Cruz (FIOCRUZ)instacron:FIOCRUZporhttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/438/223https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/438/675Copyright (c) 2015 Vigilância Sanitária em Debate: Sociedade, Ciência & Tecnologia (Health Surveillance under Debate: Society, Science & Technology) – Visa em Debatehttps://creativecommons.org/licenses/by-nc-nd/4.0info:eu-repo/semantics/openAccessRosa, Leonardo Souza daGarbin, Cassiane MariniZamboni, LuanaBonacina, Marlice Salete2023-06-27T14:59:48Zoai:ojs.visaemdebate.incqs.fiocruz.br:article/438Revistahttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebatePUBhttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/oaiincqs.visaemdebate@fiocruz.br || gisele.neves@fiocruz.br2317-269X2317-269Xopendoar:2023-06-27T14:59:48Vigilância Sanitária em Debate - Fundação Oswaldo Cruz (FIOCRUZ)false
dc.title.none.fl_str_mv Physicochemical Quality Assessment of ultra-Pasteurized Milk Commercially in the City of Erechim-RS
Avaliação da Qualidade Físico-Química do Leite Ultra Pasteurizado Comercializado no Município de Erechim – RS
title Physicochemical Quality Assessment of ultra-Pasteurized Milk Commercially in the City of Erechim-RS
spellingShingle Physicochemical Quality Assessment of ultra-Pasteurized Milk Commercially in the City of Erechim-RS
Rosa, Leonardo Souza da
UHT Milk
Quality
Tampering
Public Health
Leite UHT
Qualidade
Adulteração
Saúde Pública
title_short Physicochemical Quality Assessment of ultra-Pasteurized Milk Commercially in the City of Erechim-RS
title_full Physicochemical Quality Assessment of ultra-Pasteurized Milk Commercially in the City of Erechim-RS
title_fullStr Physicochemical Quality Assessment of ultra-Pasteurized Milk Commercially in the City of Erechim-RS
title_full_unstemmed Physicochemical Quality Assessment of ultra-Pasteurized Milk Commercially in the City of Erechim-RS
title_sort Physicochemical Quality Assessment of ultra-Pasteurized Milk Commercially in the City of Erechim-RS
author Rosa, Leonardo Souza da
author_facet Rosa, Leonardo Souza da
Garbin, Cassiane Marini
Zamboni, Luana
Bonacina, Marlice Salete
author_role author
author2 Garbin, Cassiane Marini
Zamboni, Luana
Bonacina, Marlice Salete
author2_role author
author
author
dc.contributor.author.fl_str_mv Rosa, Leonardo Souza da
Garbin, Cassiane Marini
Zamboni, Luana
Bonacina, Marlice Salete
dc.subject.por.fl_str_mv UHT Milk
Quality
Tampering
Public Health
Leite UHT
Qualidade
Adulteração
Saúde Pública
topic UHT Milk
Quality
Tampering
Public Health
Leite UHT
Qualidade
Adulteração
Saúde Pública
description This study aimed to commercially evaluate the physicochemical quality of ultra-pasteurized milk in the city of Erechim-RS. In May and August 2014, six samples of whole UHT milk, cor-responding to six different brands, were collected, amounting to 12 samples. The sample’s quality was assessed by analyzing the following parameters: moisture, fat, protein, non-fat solids (NFS), ethanol stability 80%, relative density at 15ºC, acidity, cryoscopic index, and fraud detections by adding starch, formaldehyde, sodium hydroxide, hydrogen peroxide, and antibiotic residues. The measurements of fraud, moisture, NFS, density, acidity, and cryos-copic index were performed in triplicate as Instrução Normative Instruction no. 68/2006.The parameters, fat and protein, were determined in triplicate in an ultrasonic analyzer. The sta-tistical treatment of data was performed according to the Statistical Software 8.0. The results indicated the existence of significant differences (p < 0.05) between brands for the following parameters: moisture, fat, protein, NFS, density, acidity, and cryoscopic index. It was also found that two brands of whole milk UHT evaluated did not meet the minimum quality re-quirements in relation to protein and ESD parameters established by law. Other two brands had indications of tampering by adding starch and sodium hydroxide. From these findings, it was concluded that only two brands met all the minimum quality requirements for UHT milk.
publishDate 2015
dc.date.none.fl_str_mv 2015-05-29
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
"Peer-reviewed article"
"Artículo revisado por pares"
"Artigo avaliado pelos pares"
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/438
10.3395/2317-269x.00438
url https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/438
identifier_str_mv 10.3395/2317-269x.00438
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/438/223
https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/438/675
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by-nc-nd/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by-nc-nd/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/vnd.openxmlformats-officedocument.wordprocessingml.document
dc.publisher.none.fl_str_mv Instituto Nacional de Controle de Qualidade em Saúde
publisher.none.fl_str_mv Instituto Nacional de Controle de Qualidade em Saúde
dc.source.none.fl_str_mv Health Surveillance under Debate: Society, Science & Technology ; Vol. 3 No. 2 (2015): May; 99-107
Vigilancia en Salud en Debate: Sociedad, Ciencia y Tecnología; Vol. 3 Núm. 2 (2015): Puede; 99-107
Vigil Sanit Debate, Rio de Janeiro; v. 3 n. 2 (2015): Maio; 99-107
2317-269X
reponame:Vigilância Sanitária em Debate
instname:Fundação Oswaldo Cruz (FIOCRUZ)
instacron:FIOCRUZ
instname_str Fundação Oswaldo Cruz (FIOCRUZ)
instacron_str FIOCRUZ
institution FIOCRUZ
reponame_str Vigilância Sanitária em Debate
collection Vigilância Sanitária em Debate
repository.name.fl_str_mv Vigilância Sanitária em Debate - Fundação Oswaldo Cruz (FIOCRUZ)
repository.mail.fl_str_mv incqs.visaemdebate@fiocruz.br || gisele.neves@fiocruz.br
_version_ 1797042044111159296