Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD)
Autor(a) principal: | |
---|---|
Data de Publicação: | 2013 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Vigilância Sanitária em Debate |
Texto Completo: | https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/16 |
Resumo: | Valproic acid (VA) is used as an anticonvulsant and is used in the treatment of bipolar disorder and depression. The official analytical method for this drug in the compendia is gas chromatography, which is unavailable in many quality control laboratories. Here, we report a validated alternative method using high performance liquid chromatography with diode array detection (HPLC-DAD). The optimized parameters and conditions were as follows: C18 column (5 µm; 250 x 4 mm d.i.); flow 1.0 mL.min-1; wavelength: 210 nm; mobile phase: 55% acetonitrile (ACN) in water containing 0.05% v/v trifluoroacetic acid (TFA) (v/v). The analytical parameters that were validated included the selectivity and matrix effects, linearity, repeatability and intermediate, precision, accuracy, recovery and robustness. This method identifies VA unambiguously. In validation, the following results were obtained: good linearity in concentrations between 0.7 and 1.3 mg.mL-1 (r2 = 0.9998), relative standard deviations (RSDs) of 0.68% for repeatability and 1.23% for intermediate precision, a recovery of 99.42 to 101.55% (RSD 0.14 to 0.74%) and an accuracy of 100.68% (RSD = 0.79%). This method is robust to small variations in procedure. |
id |
FIOCRUZ-9_7236345b900dfdb6b6a71f64bc682ee5 |
---|---|
oai_identifier_str |
oai:ojs.visaemdebate.incqs.fiocruz.br:article/16 |
network_acronym_str |
FIOCRUZ-9 |
network_name_str |
Vigilância Sanitária em Debate |
repository_id_str |
|
spelling |
Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD)Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD)cromatografia líquida de alta eficiência acoplada com detector de conjunto de fotodiodosácido valpróicovalidaçãohigh performance liquid chromatographyHPLC-DADvalproic acidvalidationValproic acid (VA) is used as an anticonvulsant and is used in the treatment of bipolar disorder and depression. The official analytical method for this drug in the compendia is gas chromatography, which is unavailable in many quality control laboratories. Here, we report a validated alternative method using high performance liquid chromatography with diode array detection (HPLC-DAD). The optimized parameters and conditions were as follows: C18 column (5 µm; 250 x 4 mm d.i.); flow 1.0 mL.min-1; wavelength: 210 nm; mobile phase: 55% acetonitrile (ACN) in water containing 0.05% v/v trifluoroacetic acid (TFA) (v/v). The analytical parameters that were validated included the selectivity and matrix effects, linearity, repeatability and intermediate, precision, accuracy, recovery and robustness. This method identifies VA unambiguously. In validation, the following results were obtained: good linearity in concentrations between 0.7 and 1.3 mg.mL-1 (r2 = 0.9998), relative standard deviations (RSDs) of 0.68% for repeatability and 1.23% for intermediate precision, a recovery of 99.42 to 101.55% (RSD 0.14 to 0.74%) and an accuracy of 100.68% (RSD = 0.79%). This method is robust to small variations in procedure.Título em português: Desenvolvimento e validação de um método para a determinação de ácido valpróico em formulações farmacêuticas por cromatografia líquida de alta eficiência acoplada com detector de conjunto de fotodiodosO ácido valpróico (VA) é utilizado como anticonvulsivante e também na terapêutica da desordem bipolar e depressão. O método de análise deste medicamento nos compêndios oficiais é por cromatografia gasosa e muitos laboratórios oficiais de controle de qualidade não possuem tal equipamento. A proposta deste estudo foi desenvolver e validar um método analítico por cromatografia líquida de alta eficiência acoplada com detector de conjunto de fotodiodos para a análise deste fármaco. Os parâmetros e condições otimizados foram: coluna C18 (5 µm; 250 x 4 mm d.i.), fluxo de 1,0 mL min-1, comprimento de onda 210 nm, fase móvel 55% ACN e 45% solução 0,05% v/v de ácido trifluoracético (v/v). Os parâmetros analíticos avaliados na validação foram: seletividade e efeito matriz, linearidade, repetitividade e precisão intermediária, exatidão e robustez. A metodologia desenvolvida mostrou identificar de forma inequívoca o analito de interesse. No que concerne aos parâmetros de validação foram obtidos: faixa linear nas concentrações de 0,7 a 1,3 mg mL-1 (r2 = 0,9998), repetitividade: desvio padrão relativo (DPR) = 0,68%, precisão intermediária: DPR = 1,23%, recuperação de 99,42 a 101,55% (DPR de 0,14 a 0,74%) e exatidão de 100,68% (DPR = 0,79%). Quando submetido a pequenas variações, a metodologia mostrou-se robusta.Instituto Nacional de Controle de Qualidade em Saúde2013-02-25info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion"Peer-reviewed article""Artículo revisado por pares""Artigo avaliado pelos pares"application/pdfhttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/1610.3395/vd.v1n1.16Health Surveillance under Debate: Society, Science & Technology ; Vol. 1 No. 1 (2013): February; 52-58Vigilancia en Salud en Debate: Sociedad, Ciencia y Tecnología; Vol. 1 Núm. 1 (2013): Febrero; 52-58Vigil Sanit Debate, Rio de Janeiro; v. 1 n. 1 (2013): Fevereiro; 52-582317-269Xreponame:Vigilância Sanitária em Debateinstname:Fundação Oswaldo Cruz (FIOCRUZ)instacron:FIOCRUZenghttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/16/14Copyright (c) 2013 Vigilância Sanitária em Debate: Sociedade, Ciência & Tecnologia (Health Surveillance under Debate: Society, Science & Technology) – Visa em Debatehttps://creativecommons.org/licenses/by-nc-nd/4.0info:eu-repo/semantics/openAccessSouza, Paulo Ricardo de Souza eCarvalho, Juliana Machado deAlbert, André Luis MazzeiMoreira, Josino CostaLeandro, Katia Christina2023-06-27T14:54:35Zoai:ojs.visaemdebate.incqs.fiocruz.br:article/16Revistahttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebatePUBhttps://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/oaiincqs.visaemdebate@fiocruz.br || gisele.neves@fiocruz.br2317-269X2317-269Xopendoar:2023-06-27T14:54:35Vigilância Sanitária em Debate - Fundação Oswaldo Cruz (FIOCRUZ)false |
dc.title.none.fl_str_mv |
Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD) Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD) |
title |
Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD) |
spellingShingle |
Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD) Souza, Paulo Ricardo de Souza e cromatografia líquida de alta eficiência acoplada com detector de conjunto de fotodiodos ácido valpróico validação high performance liquid chromatography HPLC-DAD valproic acid validation |
title_short |
Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD) |
title_full |
Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD) |
title_fullStr |
Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD) |
title_full_unstemmed |
Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD) |
title_sort |
Development and validation of a method for the determination of valproic acid in pharmaceutical formulations by high performance liquid chromatography with diode array detection (HPLC-DAD) |
author |
Souza, Paulo Ricardo de Souza e |
author_facet |
Souza, Paulo Ricardo de Souza e Carvalho, Juliana Machado de Albert, André Luis Mazzei Moreira, Josino Costa Leandro, Katia Christina |
author_role |
author |
author2 |
Carvalho, Juliana Machado de Albert, André Luis Mazzei Moreira, Josino Costa Leandro, Katia Christina |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Souza, Paulo Ricardo de Souza e Carvalho, Juliana Machado de Albert, André Luis Mazzei Moreira, Josino Costa Leandro, Katia Christina |
dc.subject.por.fl_str_mv |
cromatografia líquida de alta eficiência acoplada com detector de conjunto de fotodiodos ácido valpróico validação high performance liquid chromatography HPLC-DAD valproic acid validation |
topic |
cromatografia líquida de alta eficiência acoplada com detector de conjunto de fotodiodos ácido valpróico validação high performance liquid chromatography HPLC-DAD valproic acid validation |
description |
Valproic acid (VA) is used as an anticonvulsant and is used in the treatment of bipolar disorder and depression. The official analytical method for this drug in the compendia is gas chromatography, which is unavailable in many quality control laboratories. Here, we report a validated alternative method using high performance liquid chromatography with diode array detection (HPLC-DAD). The optimized parameters and conditions were as follows: C18 column (5 µm; 250 x 4 mm d.i.); flow 1.0 mL.min-1; wavelength: 210 nm; mobile phase: 55% acetonitrile (ACN) in water containing 0.05% v/v trifluoroacetic acid (TFA) (v/v). The analytical parameters that were validated included the selectivity and matrix effects, linearity, repeatability and intermediate, precision, accuracy, recovery and robustness. This method identifies VA unambiguously. In validation, the following results were obtained: good linearity in concentrations between 0.7 and 1.3 mg.mL-1 (r2 = 0.9998), relative standard deviations (RSDs) of 0.68% for repeatability and 1.23% for intermediate precision, a recovery of 99.42 to 101.55% (RSD 0.14 to 0.74%) and an accuracy of 100.68% (RSD = 0.79%). This method is robust to small variations in procedure. |
publishDate |
2013 |
dc.date.none.fl_str_mv |
2013-02-25 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion "Peer-reviewed article" "Artículo revisado por pares" "Artigo avaliado pelos pares" |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/16 10.3395/vd.v1n1.16 |
url |
https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/16 |
identifier_str_mv |
10.3395/vd.v1n1.16 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
https://visaemdebate.incqs.fiocruz.br/index.php/visaemdebate/article/view/16/14 |
dc.rights.driver.fl_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0 info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
https://creativecommons.org/licenses/by-nc-nd/4.0 |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Instituto Nacional de Controle de Qualidade em Saúde |
publisher.none.fl_str_mv |
Instituto Nacional de Controle de Qualidade em Saúde |
dc.source.none.fl_str_mv |
Health Surveillance under Debate: Society, Science & Technology ; Vol. 1 No. 1 (2013): February; 52-58 Vigilancia en Salud en Debate: Sociedad, Ciencia y Tecnología; Vol. 1 Núm. 1 (2013): Febrero; 52-58 Vigil Sanit Debate, Rio de Janeiro; v. 1 n. 1 (2013): Fevereiro; 52-58 2317-269X reponame:Vigilância Sanitária em Debate instname:Fundação Oswaldo Cruz (FIOCRUZ) instacron:FIOCRUZ |
instname_str |
Fundação Oswaldo Cruz (FIOCRUZ) |
instacron_str |
FIOCRUZ |
institution |
FIOCRUZ |
reponame_str |
Vigilância Sanitária em Debate |
collection |
Vigilância Sanitária em Debate |
repository.name.fl_str_mv |
Vigilância Sanitária em Debate - Fundação Oswaldo Cruz (FIOCRUZ) |
repository.mail.fl_str_mv |
incqs.visaemdebate@fiocruz.br || gisele.neves@fiocruz.br |
_version_ |
1797042043310047232 |