Bond strength to dentin of total-etch and self-etch adhesive systems
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | RGO - Revista Gaúcha de Odontologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000400365 |
Resumo: | OBJECTIVE: To assess the bond strength to dentin of the Single Bond (3M ESPE) and XP Bond (Dentsply) total-etch and Adper SE Plus (3M ESPE) self-etch adhesive systems. METHODS: Fifteen healthy human third molars were randomly allocated across three different groups of five teeth each according to the adhesive system. The occlusal portion of each tooth was removed under refrigeration using a flexible diamond disc (EXTEC, Enfield, CT, USA) down to an area of dentin that did not reveal enamel, as confirmed under a 40X stereo microscope (Ramsor, São Paulo, Brazil). A standardized smear layer was created with #600 grit silicon-carbide paper. The adhesive systems were applied as per manufacturer recommendations, with the exception of the Adper SE Plus system, which was triple-polymerized. Composite resin blocks (5 mm) were placed on the dentin surface. The specimens were stored in distilled water for 24 hours at 37ºC. Using a flexible diamond disc (EXTEC, Enfield, CT, USA), toothpick-like specimens with an adhesive area of less than 1 mm² were obtained. A microtensile bond test was then carried out using a universal testing machine (KRATOS) with a crosshead speed of 0.5 mm/min. Analysis of variance (ANOVA) and Tukey's test were used for comparisons. RESULTS: The bond strength values obtained with each adhesive system were as follows: XP Bond, 96.24 MPa; Adper Single Bond, 72.39 MPa; Adper SE Plus, 49.91 MPa. CONCLUSION: In terms of bond strength to dentin, conventional adhesives outperform self-etching systems. |
id |
FSLM-1_dccfac43e6f7673c448b011aef04a61a |
---|---|
oai_identifier_str |
oai:scielo:S1981-86372014000400365 |
network_acronym_str |
FSLM-1 |
network_name_str |
RGO - Revista Gaúcha de Odontologia (Online) |
repository_id_str |
|
spelling |
Bond strength to dentin of total-etch and self-etch adhesive systemsAdhesiveDentinTensile strength OBJECTIVE: To assess the bond strength to dentin of the Single Bond (3M ESPE) and XP Bond (Dentsply) total-etch and Adper SE Plus (3M ESPE) self-etch adhesive systems. METHODS: Fifteen healthy human third molars were randomly allocated across three different groups of five teeth each according to the adhesive system. The occlusal portion of each tooth was removed under refrigeration using a flexible diamond disc (EXTEC, Enfield, CT, USA) down to an area of dentin that did not reveal enamel, as confirmed under a 40X stereo microscope (Ramsor, São Paulo, Brazil). A standardized smear layer was created with #600 grit silicon-carbide paper. The adhesive systems were applied as per manufacturer recommendations, with the exception of the Adper SE Plus system, which was triple-polymerized. Composite resin blocks (5 mm) were placed on the dentin surface. The specimens were stored in distilled water for 24 hours at 37ºC. Using a flexible diamond disc (EXTEC, Enfield, CT, USA), toothpick-like specimens with an adhesive area of less than 1 mm² were obtained. A microtensile bond test was then carried out using a universal testing machine (KRATOS) with a crosshead speed of 0.5 mm/min. Analysis of variance (ANOVA) and Tukey's test were used for comparisons. RESULTS: The bond strength values obtained with each adhesive system were as follows: XP Bond, 96.24 MPa; Adper Single Bond, 72.39 MPa; Adper SE Plus, 49.91 MPa. CONCLUSION: In terms of bond strength to dentin, conventional adhesives outperform self-etching systems.Faculdade São Leopoldo Mandic2014-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000400365RGO - Revista Gaúcha de Odontologia v.62 n.4 2014reponame:RGO - Revista Gaúcha de Odontologia (Online)instname:Faculdade São Leopoldo Mandic (FSLM)instacron:FSLM10.1590/1981-8637201400040000022648info:eu-repo/semantics/openAccessSANTOS,Ricardo Alves dosLIMA,Eliane Alves dePONTES,Mônica Maria de AlbuquerqueNASCIMENTO,Alexandre Batista Lopes doMONTES,Marcos Antônio Japiassú ResendeBRAZ,Rodivaneng2019-08-06T00:00:00Zoai:scielo:S1981-86372014000400365Revistahttp://revodonto.bvsalud.org/scielo.php?script=sci_serial&pid=1981-8637&lng=pt&nrm=isohttps://old.scielo.br/oai/scielo-oai.php||contato@revistargo.com.br1981-86370103-6971opendoar:2019-08-06T00:00RGO - Revista Gaúcha de Odontologia (Online) - Faculdade São Leopoldo Mandic (FSLM)false |
dc.title.none.fl_str_mv |
Bond strength to dentin of total-etch and self-etch adhesive systems |
title |
Bond strength to dentin of total-etch and self-etch adhesive systems |
spellingShingle |
Bond strength to dentin of total-etch and self-etch adhesive systems SANTOS,Ricardo Alves dos Adhesive Dentin Tensile strength |
title_short |
Bond strength to dentin of total-etch and self-etch adhesive systems |
title_full |
Bond strength to dentin of total-etch and self-etch adhesive systems |
title_fullStr |
Bond strength to dentin of total-etch and self-etch adhesive systems |
title_full_unstemmed |
Bond strength to dentin of total-etch and self-etch adhesive systems |
title_sort |
Bond strength to dentin of total-etch and self-etch adhesive systems |
author |
SANTOS,Ricardo Alves dos |
author_facet |
SANTOS,Ricardo Alves dos LIMA,Eliane Alves de PONTES,Mônica Maria de Albuquerque NASCIMENTO,Alexandre Batista Lopes do MONTES,Marcos Antônio Japiassú Resende BRAZ,Rodivan |
author_role |
author |
author2 |
LIMA,Eliane Alves de PONTES,Mônica Maria de Albuquerque NASCIMENTO,Alexandre Batista Lopes do MONTES,Marcos Antônio Japiassú Resende BRAZ,Rodivan |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
SANTOS,Ricardo Alves dos LIMA,Eliane Alves de PONTES,Mônica Maria de Albuquerque NASCIMENTO,Alexandre Batista Lopes do MONTES,Marcos Antônio Japiassú Resende BRAZ,Rodivan |
dc.subject.por.fl_str_mv |
Adhesive Dentin Tensile strength |
topic |
Adhesive Dentin Tensile strength |
description |
OBJECTIVE: To assess the bond strength to dentin of the Single Bond (3M ESPE) and XP Bond (Dentsply) total-etch and Adper SE Plus (3M ESPE) self-etch adhesive systems. METHODS: Fifteen healthy human third molars were randomly allocated across three different groups of five teeth each according to the adhesive system. The occlusal portion of each tooth was removed under refrigeration using a flexible diamond disc (EXTEC, Enfield, CT, USA) down to an area of dentin that did not reveal enamel, as confirmed under a 40X stereo microscope (Ramsor, São Paulo, Brazil). A standardized smear layer was created with #600 grit silicon-carbide paper. The adhesive systems were applied as per manufacturer recommendations, with the exception of the Adper SE Plus system, which was triple-polymerized. Composite resin blocks (5 mm) were placed on the dentin surface. The specimens were stored in distilled water for 24 hours at 37ºC. Using a flexible diamond disc (EXTEC, Enfield, CT, USA), toothpick-like specimens with an adhesive area of less than 1 mm² were obtained. A microtensile bond test was then carried out using a universal testing machine (KRATOS) with a crosshead speed of 0.5 mm/min. Analysis of variance (ANOVA) and Tukey's test were used for comparisons. RESULTS: The bond strength values obtained with each adhesive system were as follows: XP Bond, 96.24 MPa; Adper Single Bond, 72.39 MPa; Adper SE Plus, 49.91 MPa. CONCLUSION: In terms of bond strength to dentin, conventional adhesives outperform self-etching systems. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000400365 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372014000400365 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1981-8637201400040000022648 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Faculdade São Leopoldo Mandic |
publisher.none.fl_str_mv |
Faculdade São Leopoldo Mandic |
dc.source.none.fl_str_mv |
RGO - Revista Gaúcha de Odontologia v.62 n.4 2014 reponame:RGO - Revista Gaúcha de Odontologia (Online) instname:Faculdade São Leopoldo Mandic (FSLM) instacron:FSLM |
instname_str |
Faculdade São Leopoldo Mandic (FSLM) |
instacron_str |
FSLM |
institution |
FSLM |
reponame_str |
RGO - Revista Gaúcha de Odontologia (Online) |
collection |
RGO - Revista Gaúcha de Odontologia (Online) |
repository.name.fl_str_mv |
RGO - Revista Gaúcha de Odontologia (Online) - Faculdade São Leopoldo Mandic (FSLM) |
repository.mail.fl_str_mv |
||contato@revistargo.com.br |
_version_ |
1754204121157599232 |